P703 Installation Guide 

70” LCD Display 

 

 

 

 

 

 

 

 

 

 

 

       

Rev 1.0 

 

www.necdisplay.com

  

 

 

 

 

 

 

 

P703 

 

             

Page 8 of 9

 

 

Input Panels: 

Bottom:

 

 

 
 

 
Control Codes:

 

 

NOTE: Contact your NEC rep for codes not listed.

  

NOTE: Use a cross/reverse/null modem cable.

  

  

Cable Connection:  

  

Communication Protocol:  

 

Interface:    

 

RS-232C       

 

  

Communication System:  Asynchronous       

  

Baud Rate:    

 

9600 bps       

 

  

Data Length:   

 

8 bits         

 

 

Parity:      

 

None 

 

 

 

Stop 

Bit 

  1 

bit 

   

Communication Code: 

ASCII 

 

 
 

 

Interface:    

 

Ethernet (CSMA/CD 

 

  

Communication System:  TCP/IP (Internet Protocol Suite)        

  

Communication Layer: 

Transport layer (TCP)   

IP Address: 

 

192.168.0.10 (default out of box)       

  

Port Number: 

 

7142 (Fixed) 

 
 
 

 

 

 
NOTE: 

If so desired, jumper “Request to send” and “Clear to Send” together on both ends of the cable to simplify cable connection. 

These connections are not required. The only connections required are pins 2 (TxD), 3 (RxD) and 5 (GND). 

Transmit Data+
Transmit Data-
Receive Data+

Receive Data-

Not Used
Not Used

Not Used
Not Used

Summary of Contents for P703

Page 1: ...ed as a reference guide to supply useful information for a design or installation It is not intended to be a step by step procedure for installation Any ceilings or walls must be strong enough to support the monitor and the installation must be in accordance with any local building codes All mounts should make secure contact to wood studs 4 3 sources can be displayed on the 16 9 screen in either n...

Page 2: ...ons below are minimum recommended for proper ventilation when the unit is in a recessed area NOTE The ventilation space should not be covered or closed off at the front of the opening If for some reason the opening needs to be covered other means of ventilation will need to be incorporated into the design Contact NEC for design review and recommendations ...

Page 3: ...NEC Display Solutions of America Inc P703 Installation Guide 70 LCD Display Rev 1 0 www necdisplay com P703 Page 3 of 9 Display dimensions ...

Page 4: ...NEC Display Solutions of America Inc P703 Installation Guide 70 LCD Display Rev 1 0 www necdisplay com P703 Page 4 of 9 Display dimensions cont ...

Page 5: ...NEC Display Solutions of America Inc P703 Installation Guide 70 LCD Display Rev 1 0 www necdisplay com P703 Page 5 of 9 Display Dimensions with ST 801 stand ...

Page 6: ...NEC Display Solutions of America Inc P703 Installation Guide 70 LCD Display Rev 1 0 www necdisplay com P703 Page 6 of 9 Optional Table Top Stand Dimensions ST 801 ...

Page 7: ...NEC Display Solutions of America Inc P703 Installation Guide 70 LCD Display Rev 1 0 www necdisplay com P703 Page 7 of 9 Dimensions of Optional Wall Mount Kit WMK 3257 ...

Page 8: ...Length 8 bits Parity None Stop Bit 1 bit Communication Code ASCII Interface Ethernet CSMA CD Communication System TCP IP Internet Protocol Suite Communication Layer Transport layer TCP IP Address 192 168 0 10 default out of box Port Number 7142 Fixed NOTE If so desired jumper Request to send and Clear to Send together on both ends of the cable to simplify cable connection These connections are not...

Page 9: ...r s IP address pd_index html Note that the LAN Power needs to be turned on in order for the display to be controlled while the units are off All displays are set to the IP address 192 168 0 10 out of the box Communicating network PC needs to be on the same subnet as display that is being communicated with NOTE Menus on the left side of the above screenshot can be altered to control the display Men...

Reviews: