11
1
2
3
Replacing the Lamp
To replace the lamp, first switch off the power, wait for the cooling fans to stop and
disconnect the power plug from the outlet. Now, wait about 60 minutes before
replacing the lamp. Attempts to replace the lamp during operation or immediately
after operation has stopped will cause burns because of the high temperature.
CAUTION!
Be careful not to catch your fingers when opening or closing the projector
mounting adapter.
CAUTION!
When performing the lamp replacement work, take care not to exert force on the
projector. Application of a large force could cause the projector to fall and cause injury.
WARNING!
Open the Projector Mounting Adapter
Loosen the screw on the front of the projector mounting adapter. (The screw does not
come detached from the fitting.)
Place your hand underneath the projector so that the mounting adapter does not open
suddenly.
Replacing the Lamp
Please refer to the instruction manual of the replacement lamp kit (Model NP10LP). and
the user's manual on the CD-ROM or Important Information (paper) supplied with the
projector.
Return the Projector to the Original Condition
Follow the procedure in the reverse order to fix the projector mounting adapter in place.