©NEC Display Solutions, Ltd. 2014-2020
35
Response
When the command succeeds
23h 96h
<ID1>
<ID2>
06h
<DATA01>
-
<DATA06>
<CKS>
Data part
Item
Description
DATA01
Target
00h
Lamp 1
01h
Lamp 2
DATA02
Content
01h
Lamp usage time (seconds)
04h
Lamp remaining life (%)
DATA03 - 06
Obtained information
When the command fails
A3h 96h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>
<CKS>
Response example
When the lamp usage time is18000 seconds (5 hours)
23h 96h
<ID1>
<ID2>
06h 00h 01h 50h 46h 00h 00h
<CKS>
Lamp usage time (DATA03 - DATA06) = 18000 / 3600 = 5 hours
Information
・
While the lamp usage time can be obtained in one-second units, the information is updated at one-minute
intervals.
・
If the lamp replacement deadline is exceeded, a negative value is returned as the lamp remaining life (%).