background image

 
 

 
 

© NEC Corporation 2016 

Reference Sites 

Name 

URL 

ESMPRO 

http://www.58support.nec.co.jp/global/download/

 

-> ESMPRO 

 
 

Words and Term 

名前

 

説明

 

Express Report Service 

Reportservice of NEC Corporation to know the trouble of the 

servers. There are two routes  to  realize  Express Report 
Service,    one is from NEC ESMPRO ServerAgentService and 
the other is from iLO, using Express Report Service 

(MG).

 

Express Report Service

(MG)

 

Report service using the error information of the server from 
iLO, using Express Report Service 

(MG) software

NEC ESMPRO ServerManager 

Server  management software. It enables the integrative 
management of multiple servers. 

NEC ESMPRO ServerAgentService  Agent software which is installed on Management Target 

Server. 

iLO 

Means Integrated Lights-Out. It is server management chip 

embedded on the server mother board.  It is called 
Baseboard Management Controller generally. 

IML 

Means  Integrated Management Log.  It is a log of server 
saved in iLO. 

 
 

Revision History 

Date 

Revision 

Description 

Nov 22, 2017 

1.0 

Initial release. 

 

 

 

Summary of Contents for NEC Express5800 Series

Page 1: ...NEC Express5800 iLO Embedded Server Notice for Express Report Service MG Revision 1 0 Nov 22 2017 NEC Corporation...

Page 2: ...rence Sites 4 Words and Term 4 Revision History 4 1 Introduction 5 2 About NEC Express Report Service 6 3 NEC iLO IML SNMP Trap List 7 4 Precautions for Report Target Events 9 4 1 Events which doesn t...

Page 3: ...er Corporation name and trade name are trademarks or registered trademarks Cautions Unauthorized copying of all or part of this manual is prohibited The contents of this manual may change in the futur...

Page 4: ...service using the error information of the server from iLO using Express Report Service MG software NEC ESMPRO ServerManager Server management software It enables the integrative management of multip...

Page 5: ...orporation 2016 5 1 Introduction This document describes the notice of NEC Express Report Service MG for NEC Express5800 Servers which has iLO on its mother board Please check the NEC iLO IML SNMP Tra...

Page 6: ...ze NEC Express Report Service shown below NEC Express Report Service Agent software NEC ESMPRO ServerAgentService detects error information of the server and report to the Maintenance Company through...

Page 7: ...Trap List NEC iLO IML SNMP Trap List is a list of IML and its SNMP trap information for NEC Express5800 iLO Embedded Servers Occurrence of each events is depends on the model or configuration of the...

Page 8: ...e sent from NEC ESMPRO ServerAgentService to NEC Service Center or not SNMP Trap Information Express Report Service MG Shows the information whether the item will be sent to NEC Service Center with Ex...

Page 9: ...Sensor 2 Location 3 Temperature 4 0x2 0x2a Critical 1 Storage System Overheating 2Slot 3 Temperature Sensor 4 Location 5 Temperature 6 0x2 0x2b Critical 1 Overheating Temperature Sensor 2 Location 3 T...

Page 10: ...Failure Battery Shutdown Event Code 0x 3 0xa 0x315 Critical An uncorrectable memory error was detected prior to this system boot 0xa 0x323 Caution 1 Dual microSD Device Error The microSD card in Slot...

Page 11: ...One or more configuration changes since the last boot may not have taken affect 0xa 0x454 Caution NVDIMM Error Persistent Memory Address Range Scrub error threshold exceeded on Processor 1 DIMM 2 SN 3...

Page 12: ...te 0xa 0x2408 Caution Slot 1 Error Firmware image recovery not successful 0xa 0x2410 Caution Slot 1 Error Controller I O timeout failure 0xa 0x2416 Caution 1 Error Controller firmware not ready 0xb 0x...

Page 13: ...al KTI initialization error has been detected 1 Major Code 2 Minor Code 3 0x32 0x221 Critical Unknown Initialization Error The system has experienced a fatal initialization error 1 Major Code 2 Minor...

Page 14: ...image could not be authenticated 0x32 0x462 Critical Uncorrectable Memory Error Threshold Exceeded 1 2 DIMM 3 The DIMM is mapped out and is currently not available 0x32 0x3011 Critical MemBIST MEMTEST...

Page 15: ...CODE 0x1a FAN Failure Report is required 6035 Report Target SNMP Trap ID 6035 became and report target of Express Report Service MG because FAN Failure IML is an report target of Express Report Servi...

Page 16: ...NEC Corporation 2016 16 End...

Reviews: