background image

NEC Express5800/120Lh Operation Manual for Microsoft®Windows Server™ 2003 x64 Editions

 

 

 

16 

 

 Graphics Accelerator Driver                                                                                   

 

The graphic accelerator driver provided as a standard driver is installed automatically at 

the time of system update. 

 

When the graphic accelerator driver is deleted after installing the operating system and 

re-installation is required, use the following procedure. 

 

1.  From  the  start  menu,  point  [Programs]  then  [Accessories],  and  click  [Windows 

Explorer]. 

 

2.  Double-click 

the 

[SETUP.EXE] 

icon 

in 

the 

<storage-destination-folder-name>:¥WINNT¥W2K3AMD¥VIDEO directory. 

 

IMPORTANT

 

The graphics accelerator driver for the Windows Server 2003 x64 

Editions supports as standard the use of a remote KVM console 

with  the  N8115-02CP01  advanced  remote  management  card 

installed.    So it is unnecessary to install a dedicated driver. 

 

3.  Perform operations according to the message instructions. 

Installation of the driver starts. 

 

IMPORTANT

 

When message 

"Digital Signature could not been found." appears, 

click [Yes] and continue installation. 

 

4.  Restart the system according to the instructions displayed on the screen. 

 

 

  When  Additionally  Connecting  a  SCSI  Controller  (N8103-56F/95/ 

N8190-126)                                                                                                                     

 

When a SCSI controller (N8103-56F/95/N8190-126) is added to the system, its driver is 

installed  automatically  by  the  Plug  and  Play  function  of  the  OS.    So,  no  special 

operation is required. 

 

 

 When Additionally Connecting a SCSI Controller (N8103-75)                                                                                                                   

 

When  a  SCSI  controller  (N8103-75)  is  added  to  the  system,  its  driver  is  installed 

automatically by the Plug and Play function of the OS.    Also, driver update is required.   

By running the system update, the driver is updated. 

 

 Installing RAID Controller Driver (N8103-80F/81F)                                                                                                               

 

To additionally install the N8103-80F/81F in a system containing Windows 2003, connect 

the controller and take the following steps to install the driver: 

 

1.  When the [Found New Hardware Wizard] dialog box appears, click [Next]. 

 

2.  When the [Install Hardware Device Drivers] dialog box appears, select [Search 

for a suitable driver for my device (Recommended)], and click [Next]. 

 

3.  When the [Locate Driver Files] dialog box appears, select [Floppy disk drives], 

insert  "Windows  Server  2003  x64  Edition  OEM-DISK  for  NEC 

EXPRESSBUILDER" into the floppy disk drive, and click [Next]. 

 

4.  When the [Driver Files Search Results] dialog box appears, click [Next]. 

 

Summary of Contents for NEC Express5800 Series

Page 1: ...8 80 00 0 1 12 20 0L Lh h O Op pe er ra at ti io on n M Ma an nu ua al l F Fo or r M Mi ic cr ro os so of ft t W Wi in nd do ow ws s S Se er rv ve er r 2 20 00 03 3 S St ta an nd da ar rd d x x6 64 4...

Page 2: ...NOTE The NEC difference module for the Windows Server 2003 x64 Edition for Express5800 120Lh is dedicated to the Express5800 120Lh This module cannot be used for other devices The installation procedu...

Page 3: ...ndard x64 Edition Microsoft Windows Server 2003 Enterprise x64 Edition CD ROM To be purchased separately Called the Windows Server 2003 x64 Edition CD ROM hereinafter or Backup CD ROM Microsoft Window...

Page 4: ...Follow the steps below to create the disk 1 Prepare one empty 3 5 inch floppy disk formatted to the 1 44MB format 2 Start the operating system 3 Download the NEC difference module See Downloading the...

Page 5: ...2003 x64 Editions must match IMPORTANT Perform activation within 30 days after the installation After 30 days elapse the system may be locked The COA label may be adhered to the device Optional Board...

Page 6: ...ical drive left connected at the time of installation file system conversion may not be performed correctly If correct file system conversion is not performed remove the magneto optical drive and perf...

Page 7: ...for these applications to the partition size When the installed memory size is 512MB for example the partition size is calculated using the above expression as follows 4100MB 512MB 1 5 512MB 1MB appli...

Page 8: ...n SCSI HostRAID is to be used set HostRAID to Enabled with the SCSI Select Utility to create a RAID drive before installation For how to create a RAID drive refer to the description of RAID configurat...

Page 9: ...r details refer to Readme txt included in the BIOS download data of the device 3 From the BIOS Setup menu select Exit Save Changes Exit and select Yes to restart the system 4 Set the Windows Server 20...

Page 10: ...be pressed the subsequent steps are unnecessary Perform setup operation according to the instructions displayed on the screen For details refer to First Step Guide 6 When the following message is dis...

Page 11: ...999 999MB can be set if the default partition size is not used After the file copy operation the system restarts automatically TIPS The floppy disk and the CD ROM need not be removed If the floppy dis...

Page 12: ...of the system by adding or removing hardware or Operating system software components or repair the system you must run the system update again 1 Log on to the system with an account having an administ...

Page 13: ...tolerant environment and improve throughput between the device and switch Before this function can be used PROSet is required To install PROSet follow the steps below 1 Start Explorer Procedure in the...

Page 14: ...Connection Properties dialog box appears The procedure in the case of the standard start menu Click Start menu click Control Panel click Network Connections and click Local Area Connection The proced...

Page 15: ...N8104 103 112 113 storage destination folder name WINNT W2K3AMD NS1 PRO1000 WS0 3_32E Installing the network driver for an optional board 1 Start the device manager 2 Select Network adapters and doubl...

Page 16: ...rding to the instructions displayed on the screen When Additionally Connecting a SCSI Controller N8103 56F 95 N8190 126 When a SCSI controller N8103 56F 95 N8190 126 is added to the system its driver...

Page 17: ...5800 120Lh Operation Manual for Microsoft Windows Server 2003 x64 Editions 17 5 Copying of the driver is completed and the Completion of the new hardware detection wizard dialog box below appears Clic...

Page 18: ...e click Advanced 3 In the Startup and Recovery box click Settings 4 In the text box enter the location where debug information is to be written and click OK When writing debug information under the fi...

Page 19: ...the change made a message may be displayed asking you to restart the system Restart the system according to the message Setting Dr Watson Dr Watson is a debugger for application errors When detecting...

Page 20: ...ns have been installed the following event log may be recorded Source DCOM Type Error Event ID 10016 Explanation According to the default authority setting in the computer the access permission for pe...

Page 21: ...e HostingModel property registered for the provider to an account having the minimum privilege with which necessary functions can be executed This poses no system operation problem When the Windows Se...