CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIE (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
Page 336
ND-70928 (E), Issue 3.0
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
SW3 (DIP SW)
1
Always set to ON
2
Always set to ON
3
Always set to ON
4
Always set to OFF
JPS (Jumper pin)
Balanced transmission: 120
Ω
(For
twisted-pair cable)
Left
TA is grounded on the transmission
line: 75
Ω
(For coaxial cable)
JPR (Jumper pin)
Right
RA is grounded on the transmission
line: 75
Ω
(For coaxial cable)
Balanced transmission: 120
Ω
(For
twisted-pair cable)
E1Z (Jumper pin)
Right
Line impedance:
75
Ω
(For coaxial cable)
Line impedance:
120
Ω
(For twisted-pair cable)
SRT (Jumper pin)
Right
Line impedance:
75
Ω
(For coaxial cable)
Line impedance:
120
Ω
(For twisted-pair cable)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON
ON
ON
OFF
Right
Left
Left
Left