CHAPTER 2

SYSTEM DESCRIPTION

1.

SYSTEM OUTLINE

Remote PIMs can be installed separately in the same building or between the offices via the Public Switching
Telephone Network (PSTN).

The customers in the remote site can use the same service features as in the main site. Remote PIMs are connected
to the main site by T1 (1.5 Mbps) digital interface.

Figure 2-1

 shows an outline of the Remote PIM System.

Figure 2-1    Remote PIM System Outline

Note:

The remote PIM contains station and trunk cards. A CPU card is not required in the remote offices.

PIM

1.5M

 (T1)

(Main Site)

OFFICE A

NEAX2000 IVS

PIM

OFFICE D

(Remote Site)

PIM

OFFICE B

(Remote Site)

PIM

OFFICE C

(Remote Site)

1.5M (T1)

1.5

(T1

)

Summary of Contents for NEAX2000 IVS

Page 1: ...ND 46550 E ISSUE 2 STOCK 151944 Remote PIM System Manual SEPTEMBER 1998 NECAmerica Inc ...

Page 2: ... America Inc has prepared this document for use by its em ployees and customers The information contained herein is the property of NEC America Inc and shall not be reproduced without prior written approval from NEC America Inc NEAX and Dterm are registered trademarks of NEC Corporation Copyright 1998 NEC America Inc Printed in the U S A ...

Page 3: ... 6 5 SYSTEM CAPACITY 8 6 SYSTEM CONDITIONS 9 7 TIME SLOT ALLOCATION 10 CHAPTER 3 INSTALLATION 13 1 PRECAUTION IN HANDLING 13 2 INSTALLATION PROCEDURE 16 2 1 Installation Procedure for Main Site 18 2 1 1 Switch Setting of DAIA Card 18 2 1 2 Mounting of DAIA Card 23 2 1 3 Switch Setting of DAIC Card 24 2 1 4 Mounting of DAIC Card 28 2 1 5 BUS Cable Connection 29 2 2 Installation Procedure for Remote...

Page 4: ...orm PIM 45 2 2 7 Mounting of Line Trunk Card on 1000 IVS PIM 48 2 2 8 Mounting of Line Trunk Card on PIM N UB 64 port PIM 51 2 2 9 Power Failure Transfer PFT 54 2 3 Connection Between Main Site and Remote Site 62 2 3 1 DTI Connection at Main Site 62 2 3 2 DTI Connection at Remote Site 65 2 4 MP Reset 66 CHAPTER 4 TROUBLESHOOTING 67 ...

Page 5: ...ction Continued 33 3 14 PN DAIB Card 34 3 15 Mounting Location of DAIB Card 39 3 16 Mounting Location of DAIB Card Continued 40 3 17 Mounting Location of DAIC Card Remote PIM 41 3 18 Mounting Location of DAIC Card Remote PIM Continued 42 3 19 Mounting Location of DAIC Card Remote PIM Continued 43 3 20 DAIB DAIC Cable Connection 44 3 21 Mounting Location of Line Trunk Card Small Platform 45 3 22 Lo...

Page 6: ...7 3 34 Mounting PZ 8PFTA Card to PIM 58 3 35 PFT Connector Pin Assignment 59 3 36 MDF Cross Connection for PFT PZ 8PFTA 60 3 37 DTI Cable Connection via LTC Connector 62 3 38 Example of DTI Cable Connection via LTC Connector 63 3 39 DTI Cable Connection via CN Connector Main Site 64 3 40 DTI Cable Connection via CN Connector Remote Site 65 ...

Page 7: ...N DAIA Card 20 3 3 Switch Settings When Clock Signal Supplied From Master Office 22 3 4 Lamp Indications on PN DAIC Card 25 3 5 Switch Settings on PN DAIC Card 25 3 6 Lamp Indications on PN DAIB Card 35 3 7 Switch Settings on PN DAIB Card 36 3 8 LTC Connector Accommodation Small Platform 45 3 9 LTC Connector Accommodation 1000 IVS 48 3 10 LTC Connector Accommodation 51 4 1 Remedial Action on Each ...

Page 8: ...LIST OF TABLES ND 46550 E Page vi Revision 2 0 This page is for your notes ...

Page 9: ...stallation procedure for providing the Remote PIM System to the NEAX2000 IVS 2 REFERENCE MANUALS Refer to the following manuals for additional information on equipment and programming installation Installation Procedure Manual Small Platform System Manual Circuit Card Manual Command Manual Office Data Programming Manual Maintenance Manual ...

Page 10: ...CHAPTER 1 ND 46550 E Page 2 Revision 2 0 This page is for your notes ...

Page 11: ...an use the same service features as in the main site Remote PIMs are connected to the main site by T1 1 5 Mbps digital interface Figure 2 1 shows an outline of the Remote PIM System Figure 2 1 Remote PIM System Outline Note The remote PIM contains station and trunk cards A CPU card is not required in the remote offices PIM 1 5M T1 Main Site OFFICE A NEAX2000 IVS PIM OFFICE D Remote Site PIM OFFICE...

Page 12: ... number of remote sites determines the number of PIMs in one system Table 2 1 shows the available PIM configuration for the Remote PIM System Table 2 1 PIM Configuration NUMBER OF PIM AT MAIN SITE AVAILABLE NUMBER OF REMOTE SITE 1 PIM 1 FP 1 2 3 2 PIM 1 FP 1 2 3 3 PIM 2 FP 1 2 _ 4 PIM 2 FP 1 2 _ 5 PIM 3 FP 1 _ _ 6 PIM 3 FP 1 _ _ 7 PIM 4 FP _ _ _ 8 PIM 4 FP _ _ _ ...

Page 13: ...2 DAIB FP1 DAIC 1 DAIC 2 DAIA 2 FP2 DAIC 3 DAIC 4 DAIB FP2 DAIC 3 DAIC 4 DAIA 3 FP3 DAIC 5 DAIC 6 FP0 MP DAIB FP3 DAIC 5 Line TRK Line TRK Line TRK DAIC 6 Remote PIM 1 Remote PIM 2 Remote PIM 3 Remote Site Main Site 23 B Channel 1 D Channel 24 B Channel 24 B Channel 23 B Channel 1 D Channel 24 B Channel 24 B Channel 23 B Channel 1 D Channel 24 B Channel 24 B Channel ...

Page 14: ...tion from short term power interruption Two champ connectors for line trunk LTC0 to 1 and a connector for Power PWR are located at the lower front side of the PIM PN DAIA DAIA Card Interface card for Remote PIM System at main site This card provides 1 5 Mbps 24 channel digital interface firmware processor and BUS interface 1 through 3 DAIA cards must be provided at main site which corresponds to t...

Page 15: ...ired at the main site even if the system is 1 PIM configuration PN CP01 FP Card Firmware processor card For Remote PIM System CP01 card must be mounted on PIM0 at the main site even if the system is 1 PIM configuration RMT PCM 0 3 CA 1 ft 30 cm PCM signal cable This cable is used for connection between DAIA card and BUS interface card 17 TW 0 3 CONN CA A 1 ft 30 cm connection cable between DAIA ca...

Page 16: ...y DESCRIPTION CAPACITY REMARKS MAIN PIM REMOTE PIM 2000 IVS SMALL PLATFORM 72 Port 1000 IVS 48 Port Max number of DAIA card 3 Max number of DAIB card 1 1 Max number of DAIC card 6 2 1 Max number of ports on Remote Site 24 Note 1 24 Note 1 Main PIM DAIA Remote PIM DAIB 48 Note 1 48 Note 1 Main PIM 1 DAIA 2 DAIC Remote PIM 1 DAIB 2 DAIC 64 Note 1 Main PIM 1 DAIA 2 DAIC Remote PIM 1 DAIB 2 DAIC Numbe...

Page 17: ...st be installed on the main site 6 For the Remote PIM System the installation procedures for modules circuit cards and peripheral equipment are the same as those for the regular NEAX2000 IVS except the DAIA card and the DAIB card installation and the BUS cable connection Refer to the applicable manuals for detailed information 7 When the link between the main site and the remote site is lost the s...

Page 18: ...runks 1time slot for control signaling channel Note 23 time slots for Line Trunks 1time slot for control signaling channel Note Max 47 time slots for Line Trunks per Remote Site Remote Site Main Site 00 23 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 DAIC DAIC 24 time slots for Line Trunks Remote Site Main Site 00 23 DAIB DAIA 24 47 Highway Channel Highway Channel TDSW TDSW 1 When using ...

Page 19: ...runks 1 time slot for control signaling channel Note 24 time slots for Line Trunks 24 time slots for Line Trunks Max 64 time slots for Line Trunks per Remote Site Remote Site Main Site 00 23 24 47 48 63 Highway Channel 3 When using 1 DAIA card 1 DAIB card and 4 DAIC cards Note The control signalling channel is set by SW2 of DAIA DAIB card Refer to Chapter 3 sections 2 1 1 and 2 2 1 for the switch ...

Page 20: ...CHAPTER 2 ND 46550 E Page 12 Revision 2 0 This page is for your notes ...

Page 21: ...ty and the installer must engage in the work on a grounded conductive work surface Figure 3 1 illustrates the actions to take while handling circuit cards Figure 3 1 Static Electricity Guard CARD FRONT PBX frame earth of equipment Connect ground wire to FRAME GROUND SCREW Never touch components or soldered surface with bare hands WRIST STRAP When plugging unplugging circuit card When holding circu...

Page 22: ...ul not to cause damage by static electricity Figure 3 2 Static Sensitive Attention Symbol Wear a wrist strap and perform work on a grounded conductive work surface CIRCUIT CARD CIRCUIT CARD When setting switches on circuit card When carrying circuit card When carrying a circuit card around keep the card in a conductive polyethylene bag CONDUCTIVE POLYETHYLENE BAG ATTENTION Contents Static Sensitiv...

Page 23: ... 2 0 When plugging or unplugging the circuit card always hold the circuit card by its edge If you touch another area you may be exposed to hazardous voltages CAUTION CARD FRONT Never touch components or soldered surface with bare hands PBX ...

Page 24: ...es only the installation procedure exclusively required for the Remote PIM System Refer to the Installation Procedure Manual for regular installation See Section 2 1 1 See Section 2 1 2 Switch Setting of DAIC Card See Section 2 1 3 Mounting of DAIC Card Connection Between Main Site and Remote Site BUS Cable Connection END Mounting of BS00 Card See Installation Procedure Manual These procedures are...

Page 25: ...ively required for the Remote PIM System Refer to the Installation Procedure Manual for the procedures marked by Note 2 It is recommended that the Power Failure Transfer PFT is provided on the Remote Site in case the link between the main site and the remote site is lost Power Failure Transfer PFT Note 2 Switch Setting of Line Trunk Circuit Cards Mounting of Line Trunk Circuit Cards See Section 2 ...

Page 26: ...for Main Site 2 1 1 Switch Setting of DAIA Card 1 Location of Lamps Switches and Connectors see Figure 3 5 Figure 3 5 PN DAIA Card ATTENTION Contents Static Sensitive Handling Precautions Required BUS CN SENSE RUN MB SW1 PCM1 LINK RED RMT LOOP PWR BL PCM0 JPS JPR SW2 SW3 ...

Page 27: ...ly LINK Green Lights when a link between this card and a distant office is connected normally Goes out after 15 seconds of link disconnection RED Red Lights when detecting PCM signal loss or Frame Alignment signal loss RMT Red Lights when receiving a alarm signal from a distant office LOOP Not used PWR Not used BL Red Lights while data transmission on control channel D ch Flashes while FP data dow...

Page 28: ...CH NUMBER SETTING POSITION FUNCTION CHECK SW1 Rotary SW Note 1 Note 2 0 F FP Firmware Processor Number setting for DAIA card By this setting system regards DAIA card and the opposite DAIB card as one firmware processor 0 Not used 1 FP No 1 2 FP No 2 3 FP No 3 4 F Not used MB Toggle SW Note 3 UP For make busy For normal operation SW1 Piano Key SW 1 Note 4 ON For supplying 1 5 MHz clock to PLO 0 No ...

Page 29: ...e DAIB card 5 ON 6 ON 7 OFF 8 ON Table 3 2 Switch Settings on PN DAIA Card Continued SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK ON 2 1 3 4 6 8 5 7 OFF OFF OFF SWITCH NUMBER TIME SLOT NUMBER 4 5 6 7 8 OFF ON ON ON ON TS1 ON OFF ON ON ON TS2 OFF OFF ON ON ON TS3 ON ON OFF ON ON TS4 OFF ON OFF ON ON TS5 ON OFF OFF ON ON TS6 OFF OFF OFF ON ON TS7 ON ON ON OFF ON TS8 OFF ON ON OFF ON TS9...

Page 30: ...ing this card on PIM0 JPR Jumper pin Right Neutral grounding on the receiving line is provided Neutral grounding on the receiving line is not provided Table 3 3 Switch Settings When Clock Signal Supplied From Master Office CONDITIONS DAIA0 DAIA1 DAIA2 REMARKS SW1 1 SW1 2 SW1 1 SW1 2 SW1 1 SW1 2 Only one DAIA card is provided ON OFF Clock signal is sent to PLO0 of MP card via supply route 0 DAIA0 T...

Page 31: ...umber of connectors of a BUS card After mounting the card set MB switch to down position Figure 3 6 Mounting Location of DAIA Card ATTENTION Contents Static Sensitive Handling Precautions Required Main Site PIM0 PIM5 PWR LT09 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT00 Note 1 For mounting the DAIA card on the slot marked the CN connector on the DAIA card should be used Note 2 When the clock signa...

Page 32: ... 3 ND 46550 E Page 24 Revision 2 0 2 1 3 Switch Setting of DAIC Card 1 Location of Lamps Switches and Connectors See Figure 3 7 Figure 3 7 PN DAIC Card TBUS CN RUN MB SW1 RBUS LINK RED RMT LOOP PWR BL SW2 SW3 ...

Page 33: ... between the opposite DAIC card Goes out after 15 seconds of link disconnection RED Red Lights when detecting PCM signal loss or Frame Alignment signal loss RMT Red Lights when receiving an alarm signal from a distant office LOOP Not used PWR Not used BL Not used Table 3 5 Switch Settings on PN DAIC Card SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK MB Toggle SW Note UP For make busy F...

Page 34: ...Frame DTI frame configuration 24 Multi Frame 3 ON Line code AMI with ZCS Line code B8ZS 4 Not used 5 Not used 6 Not used 7 Not used 8 Not used Table 3 5 Switch Settings on PN DAIC Card Continued SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK ON 2 1 3 4 6 8 5 7 OFF OFF OFF OFF OFF OFF OFF OFF ...

Page 35: ...lugging unplugging the circuit card SW3 Dip SW 1 Set the equalizer according to the cable length between the system and the CSU OFF 2 OFF 3 OFF 4 ON When mounting this card on remote site OFF When mounting this card on main site Table 3 5 Switch Settings on PN DAIC Card Continued SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK ON 2 1 3 4 ON SW 1 SW 2 SW 3 CABLE LENGTH ON ON ON 0 131 2 ft...

Page 36: ...ards can be mounted After mounting the card set MB switch to down position STEP 3 After mounting all DAIC cards set MB switch on DAIA card to up and then down Figure 3 8 Mounting Location of DAIC Card Main Site ATTENTION Contents Static Sensitive Handling Precautions Required Main Site PIM0 PIM5 PWR LT09 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT00 DAIC CARD LT10 AP0 LT11 AP1 LT12 AP2 LT13 AP3 LT1...

Page 37: ...on one PIM the 17 TW 0 3 CONN CA A is required When the system is more than one PIM configuration the DAIA cards must be mounted on the first last PIM due to the number of connectors of a BUS card Figure 3 9 BUS DAIA Cable Connection 1 1 PIM Configuration BS00 DAIA BS00 DAIA DAIA BS00 DAIA DAIA RMT PCM 0 3 CA 17 TW 0 3 CONN CA A DAIA BUS DAIA BUS DAIA DAIA BUS DAIA DAIA When mounting 1 DAIA card W...

Page 38: ... DAIC Cable Connection 1 1 PIM Configuration RMT PCM 0 3 CA 17 TW 0 3 CONN CA A DAIC BUS When mounting 1 DAIA card and 1 DAIC card When mounting 2 DAIA cards and 2 DAIC cards TBUS RBUS CN2 CN1 When mounting 3 DAIA cards and 3 DAIC cards PIM0 48 TW 0 2 CONN CA DAIA PCM1 PCM0 DAIC BUS TBUS RBUS CN2 CN1 PIM0 DAIA PCM1 PCM0 DAIC BUS TBUS RBUS CN2 CN1 PIM0 DAIA PCM1 PCM0 DAIC DAIA DAIC DAIA DAIC DAIA ...

Page 39: ...0 3 CA DAIC BUS When mounting 1 DAIA card and 2 DAIC cards on upper PIM When mounting 2 DAIA cards and 4 DAIC cards on 2 PIMs CN2 CN1 48 TW 0 2 CONN CA DAIA PCM1 PCM0 48 TW 0 7 CONN CA CN1 CN2 PIM0 DAIC TBUS RBUS LAST PIM DAIC BUS CN2 CN1 DAIA PCM1 PCM0 DAIC TBUS RBUS LAST PIM CN2 CN1 PCM1 PCM0 TBUS RBUS PIM0 DAIC BUS DAIA DAIC ...

Page 40: ...3 DAIA cards and 4 DAIC cards on 2 PIMs When mounting 3 DAIA cards and 5 DAIC cards on 2 PIMs CN2 CN1 48 TW 0 2 CONN CA DAIA PCM1 PCM0 48 TW 0 7 CONN CA DAIC TBUS RBUS LAST PIM DAIC BUS CN2 CN1 DAIA PCM1 PCM0 DAIC TBUS RBUS LAST PIM CN2 CN1 PCM1 PCM0 TBUS RBUS PIM0 DAIC BUS DAIA DAIC 17 TW 0 3 CONN CA A DAIA BUS CN2 CN1 DAIA PCM1 PCM0 DAIC TBUS RBUS PIM0 DAIC DAICDAIA ...

Page 41: ...on Continued 2 Multiple PIM Configuration continued DAIC BUS When mounting 3 DAIA cards and 6 DAIC cards on last PIM CN2 CN1 DAIA CN1 CN2 PIM0 DAIC TBUS RBUS LAST PIM RMT PCM 0 3 CA 48 TW 0 2 CONN CA 48 TW 0 7 CONN CA 17 TW 0 3 CONN CA A BUS DAICDAIA DAIC DAIC DAIA DAIC PCM0 PCM1 ...

Page 42: ...dure for Remote Site 2 2 1 Switch Setting of DAIB Card 1 Location of Lamps Switches and Connectors see Figure 3 14 Figure 3 14 PN DAIB Card ATTENTION Contents Static Sensitive Handling Precautions Required BUS CN SENSE RUN MB SW1 LINK RED RMT LOOP BL JPS JPR SW2 SW3 ...

Page 43: ...normally LINK Green Lights when a link between this card and a distant office is connected nor mally Goes out after 15 seconds of link disconnection RED Red Lights when detecting PCM signal loss or Frame Alignment signal loss RMT Red Lights when receiving a alarm signal from a distant office LOOP Not used BL Red Lights while data transmission on control channel D ch Flashes while FP data downloadi...

Page 44: ... set as shown by the figure and the setting of the switch varies with the system concerned Table 3 7 Switch Settings on PN DAIB Card SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK SW1 Rotary SW 0 F Always set to 0 1 F Not used MB Toggle SW Note UP For make busy For normal operation SW1 Piano Key SW 1 Always set to OFF 2 Always set to OFF 3 Always set to OFF 4 Always set to OFF 0 ON OFF ...

Page 45: ...e DAIA card 5 ON 6 ON 7 OFF 8 ON Table 3 7 Switch Settings on PN DAIB Card Continued SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK ON 2 1 3 4 6 8 5 7 OFF OFF OFF SWITCH NUMBER TIME SLOT NUMBER 4 5 6 7 8 OFF ON ON ON ON TS1 ON OFF ON ON ON TS2 OFF OFF ON ON ON TS3 ON ON OFF ON ON TS4 OFF ON OFF ON ON TS5 ON OFF OFF ON ON TS6 OFF OFF OFF ON ON TS7 ON ON ON OFF ON TS8 OFF ON ON OFF ON TS9...

Page 46: ...ided Neutral grounding on the transmitting line is not provided JPR Jumper pin UP Neutral grounding on the receiving line is provided Neutral grounding on the receiving line is not provided Table 3 7 Switch Settings on PN DAIB Card Continued SWITCH NAME SWITCH NUMBER SETTING POSITION FUNCTION CHECK ON 2 1 3 4 ON SW 1 SW 2 SW 3 CABLE LENGTH ON ON ON 0 131 2 ft 0 40 m ON ON OFF 131 2 262 5 ft 40 80 ...

Page 47: ...TEP 2 Mount DAIB card in the MP slot on the Remote PIM STEP 3 After mounting the card set MB switch to down position Figure 3 15 Mounting Location of DAIB Card ATTENTION Contents Static Sensitive Handling Precautions Required Remote PIM DAIB CARD LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 MP P W R Small Platform ...

Page 48: ...Page 40 Revision 2 0 Figure 3 16 Mounting Location of DAIB Card Continued ATTENTION Contents Static Sensitive Handling Precautions Required Remote PIM DAIB CARD LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 MP P W R 1000 IVS ...

Page 49: ...e PIM A maximum of two DAIC cards can be mounted After mounting the card set MB switch to down position STEP 3 After mounting all DAIC cards set MB switch on DAIB card to up and then down Figure 3 17 Mounting Location of DAIC Card Remote PIM ATTENTION Contents Static Sensitive Handling Precautions Required Remote PIM DAIC CARD LT00 LT01 LT02 LT03 LT04 LT05 LT06 AP00 LT07 AP01 LT08 AP02 LT09 AP03 L...

Page 50: ... 0 Figure 3 18 Mounting Location of DAIC Card Remote PIM Continued ATTENTION Contents Static Sensitive Handling Precautions Required Remote PIM DAIC CARD LT00 LT01 LT02 LT03 LT04 AP00 LT05 AP01 LT06 AP02 LT07 AP03 LT08 AP04 MP P W R 1000 IVS ...

Page 51: ...ion of DAIC Card Remote PIM Continued ATTENTION Contents Static Sensitive Handling Precautions Required Remote PIM DAIC CARD LT00 LT01 LT02 LT03 LT04 LT05 LT14 AP4 LT13 AP3 LT12 AP2 LT11 AP1 LT10 AP0 P W R PIM N UB LT06 LT07 LT08 LT09 LT15 AP5 LT16 AP6 MP FP AP7 BUS AP8 ...

Page 52: ...onnection Connect the DAIB card to the DAIC card by the 48 TW 0 2 CONN CA as shown in Figure 3 20 Figure 3 20 DAIB DAIC Cable Connection DAIC DAIB TBUS RBUS BUS When mounting 1 DAIC card 48 TW 0 2 CONN CA DAIC DAIB TBUS RBUS BUS DAIC When mounting 2 DAIC cards ...

Page 53: ...CTOR CARD SLOT NUMBER Small Platform LTC0 LT00 LT02 LTC1 LT03 LT05 LTC2 LT06 LT07 LTC1 LTC0 LTC2 BWB FRONT P W R Remote PIM LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 MP LINE TRUNK Note 1 The CSI card can not be used on the Remote PIM Note 2 One port of the last 24 ports can not be used for line trunk because it is used for control signaling channel CARD 1 2 3 1 When providing only one...

Page 54: ...0269 0268 0267 0266 0265 0264 0279 0278 0277 0276 0275 0274 0273 0272 0287 0286 0285 0284 0283 0282 0281 0280 0295 0294 0293 0292 0291 0290 0289 0288 0303 0302 0301 0300 0299 0298 0297 0296 0311 0310 0309 0308 0307 0306 0305 0304 0319 0318 0317 0316 0315 0314 0313 0312 LT02 LT01 LT00 SLOT No LEN When opposite DAIA card is set to FP No 2 0391 0390 0389 0388 0387 0386 0385 0384 0399 0398 0397 0396 0...

Page 55: ...3 0281 0409 28 3 0154 0282 0410 29 4 0155 0283 0411 30 5 0156 0284 0412 31 6 0157 0285 0413 32 7 0158 0286 0414 33 8 0159 0287 0415 34 9 0160 0288 0416 LT04 35 10 0161 0289 0417 36 11 0162 0290 0418 37 12 0163 0291 0419 38 13 0164 0292 0420 39 14 0165 0293 0421 40 15 0166 0294 0422 41 16 0167 0295 0423 42 17 0168 0296 0424 LT05 43 18 0169 0297 0425 44 19 0170 0298 0426 45 20 0171 0299 0427 46 21 0...

Page 56: ...02 LT03 LT04 LT05 LT06 LT07 LT08 1 When providing DAIB card only Max 23 ports LT01 LT03slot 2 When providing one DAIB card and one DAIC card Max 4 ports LT00 LT08 slot Mounted DAIB in MP mountedDAIC in LT07 so LT 08 is available for 8 ports card 3 When DAIC is mounted in slot 07 slot 06 must use the 4 port Line Trunk card so that the last 4 ports of slot 06 do not interfere with the DAIC card and ...

Page 57: ...rd When an 8 port card is mounted in Slot 04 Slot 05 can only be mounted with the following card PN M03 LT03 LT02 LT01 SLOT No LEN When opposite DAIA card is set to FP No 1 0319 0318 0317 0316 0315 0314 0313 0312 0263 0262 0261 0260 0259 0258 0257 0256 0271 0270 0269 0268 0267 0266 0265 0264 0279 0278 0277 0276 0275 0274 0273 0272 0287 0286 0285 0284 0283 0282 0281 0280 0287 0286 0285 0284 0295 02...

Page 58: ...276 0404 47 22 0149 0277 0405 48 23 0150 0278 0406 49 24 LEN0151 0279 0407 50 MN 25 MJ LTC1 FP1 FP2 FP3 26 1 LEN0152 0280 0408 LT04 LT05 27 2 0153 0281 0409 28 3 0154 0282 0410 29 4 0155 0283 0411 30 5 0156 0284 0412 31 6 0157 0285 0413 32 7 0158 0286 0414 33 8 0159 0287 0415 34 9 0160 0288 0416 LT06 LT07 35 10 0161 0289 0417 36 11 0162 0290 0418 37 12 0163 0291 0419 38 13 0164 0292 0420 39 14 016...

Page 59: ... LT05 LTC1 LT06 LT09 LT10 LT11 LTC2 LT12 LT15 LTC1 LTC0 LTC2 BWB FRONT P W R Remote PIM LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 MP LINE TRUNK CARD LT11 LT12 LT13 LT14 LT15 1 2 3 1 When providing one DAIB card only Max 23 ports LT00 LT05 slots 2 When providing one DAIB card and one DAIC card Max 47 ports LT00 LT11 slots 3 When providing one DAIB card and two DAIC cards Max 64 ports L...

Page 60: ...19 0258 0262 0266 0270 0274 0278 0282 0286 0290 0294 0298 0302 0306 0310 0314 0318 0257 0261 0265 0269 0273 0277 0281 0285 0289 0293 0297 0301 0305 0309 0313 0317 0256 0260 0264 0268 0272 0276 0280 0284 0288 0292 0296 0300 0304 0308 0312 0316 LT00 LT01 LT02 LT03 LT04 LT05 LT06 LT07 LT08 LT09 LT10 LT11 LT12 LT13 LT14 LT15 LEN Slot No When opposite DAIA card is set to FP No 3 0387 0391 0395 0399 040...

Page 61: ...281 0409 28 3 0154 0282 0410 29 4 0155 0283 0411 30 5 0156 0284 0412 31 6 0157 0285 0413 32 7 0158 0286 0414 33 8 0159 0287 0415 34 9 0160 0288 0416 LT04 35 10 0161 0289 0417 36 11 0162 0290 0418 37 12 0163 0291 0419 38 13 0164 0292 0420 39 14 0165 0293 0421 40 15 0166 0294 0422 41 16 0167 0295 0423 42 17 0168 0296 0424 LT05 43 18 0169 0297 0425 44 19 0170 0298 0426 45 20 0171 0299 0427 46 21 0172...

Page 62: ... the PZ 8PFTA card can be used as the PFT card at the remote site 1 When using PN AUCA card Figure 3 30 shows an outline of a PFT PN AUCA connection Figure 3 31 shows the MDF cross connection for a PFT PN AUCA Figure 3 30 PFT Connection Outline PN AUCA MDF TEL PN AUCA PBX MDF PN 4COT TO C O LINE ...

Page 63: ...8 33 C O R0 C O T0 C O R1 C O T1 PN 4COT 1 26 2 27 3 28 4 29 TO STATION Sta R0 Sta T0 Sta R1 Sta T1 MDF PIM0 PN AUCA LT00 5 30 6 31 7 32 8 33 J P LTC0 4Q TW 0 3 CONN CA LT01 LEN0000 No 0 LEN0001 No 1 CN1 04 03 02 01 CN1 04 03 02 01 LEN0004 No 0 LEN0005 No 1 Ring TO STATION Tip Tip Ring TO C O LINE TO C O LINE Ring Ring Tip Tip ...

Page 64: ... PFT PZ 8PFTA connection Figure 3 32 PFT PZ 8PFTA Connection Outline Note Using the PN AUCA card long line card instead of the PN 4LC card is not recommended due to the vari ations from Central Office to the PBX line quality cannot be assured LTC0 J P LEN0004 LEN0005 LEN0000 LEN0001 26 27 28 29 30 31 32 33 C O T0 C O T1 Sta T0 Sta T1 1 2 3 4 5 6 7 8 C O R0 C O R1 Sta R0 Sta R1 1 2 3 4 5 6 7 8 C O ...

Page 65: ...champ connectors of 25 pair cables to the PFT0 and PFT1 connectors on the PZ 8PFTA card as shown in Figure 3 33 Then secure them to each other using screws and tie wraps Figure 3 33 Connection of 25 Pair Cable and PZ 8PFTA 25 PAIR CABLE CHAMP CONNECTOR Provided with PZ 8PFTA PFT0 CONNECTOR PFT1 CONNECTOR PZ 8PFTA TO MDF See STEP 3 ...

Page 66: ... Revision 2 0 STEP 2 Hook the PZ 8PFTA card at the front bracket on the PIM and secure them to each other using screws and SPL washers as shown in Figure 3 34 Figure 3 34 Mounting PZ 8PFTA Card to PIM SPL WASHER SCREW PZ 8PFTA PIM ...

Page 67: ... 35 4LC T2 10 4LC R2 36 C O T2 11 C O R2 37 4COT T2 12 4COT R2 38 Sta T3 13 Sta R3 39 4LC T3 14 4LC R3 40 C O T3 15 C O R3 41 4COT T3 16 4COT R3 42 Sta T4 17 Sta R4 43 4LC T4 18 4LC R4 44 C O T4 19 C O R4 45 4COT T4 20 4COT R4 46 Sta T5 21 Sta R5 47 4LC T5 22 4LC R5 48 C O T5 23 C O R5 49 4COT T5 24 4COT R5 50 25 PFT1 PZ 8PFTA PFT1 26 Sta T6 1 Sta R6 27 4LC T6 2 4LC R6 28 C O T6 3 C O R6 29 4COT T...

Page 68: ...2 7 31 6 33 8 30 5 31 6 32 7 30 5 33 8 PN 4COT LT01 26 1 Sta R0 Sta T0 28 3 C O R0 C O T0 29 4 4COT R0 4COT T0 27 2 4LC R0 4LC T0 PFT0 TO C O LINE PZ 8PFTA No 0 P J PFT1 Tip Ring Tip Ring MDF LTC0 Remote PIM PN DAIB 25 25 T1 LEN0001 No 1 R1 T0 LEN0000 No 0 R0 T2 LEN0002 No 2 R2 T3 LEN0003 No 3 R3 PN 4LC T1 LEN0005 No 1 R1 T0 LEN0004 No 0 R0 T2 LEN0006 No 2 R2 T3 LEN0007 No 3 R3 12D PZ PW86 27V G 4...

Page 69: ...6 Sta T0 1 Sta R0 27 4LC T0 2 4LC R0 28 C O T0 3 C O R0 29 4COT T0 4 4COT R0 T0 1 Sta R0 26 Sta T0 2 4LC R0 27 4LC T0 3 C O R0 28 C O T0 4 4COT R0 29 4COT T0 T0 26 T0 1 R0 27 2 28 3 29 4 30 T0 5 R0 31 6 32 7 33 8 LTC0 J P LEN0000 LEN0004 1 R0 26 T0 2 27 3 28 4 29 5 R0 30 T0 6 31 7 32 8 33 P TO PZ 8PFTA TO PZ 8PFTA TO STATION TO PN 4LC TO C O LINE TO PN 4COT PFT0 J P 1 PFT0 CONNECTOR TO PZ PW86 TO ...

Page 70: ...en the DAIA DAIC card is mounted in the AP0 slot of PIM0 Connection of DAIC cards between the Main PIM and the Remote PIM is available in the same manner as the DAIA DAIB connection Figure 3 37 DTI Cable Connection via LTC Connector CSU MDF LTC1 LTC2 CONNECTOR TWISTED PAIR CABLE DAIA BWB MAIN PIM SHIELD TYPE Note When the Remote PIM is directly connected without CSU maximum distance is 1312 ft 400...

Page 71: ...TC Connector 43 BA1 43 18 AA1 18 42 BA0 42 17 AA0 17 17 RA 42 RB 18 TA 43 TB 19 44 20 45 MDF PIM0 P DAIA AP0 LTC1 J SEND RECEIVE TB TA RB RA TO CSU REMOTE PIM 34 33 32 T0 31 LT10 LTC1 CONNECTOR 42 RB 17 RA 43 TB 18 TA 44 19 45 20 LTC J P MDF CONNECTOR 31 32 33 34 35 36 37 38 39 RA RB TA TB T0 ...

Page 72: ...on Figure 3 39 DTI Cable Connection via CN Connector Main Site CSU MDF TWISTED PAIR CABLE DAIA BWB MAIN PIM SHIELD TYPE CN DAIA DAIC MDF CN TB TA RB RA TO CSU REMOTE PIM SEND RECEIVE 4 3 2 1 BA1 AA1 BA0 AA0 TB TA RB RA CN CONNECTOR 0 65Φ cable Note 1 When the Remote PIM is directly connected without CSU maximum distance is 1312 ft 400 m between the Main PIM and the Remote PIM Note 2 When the DAIA ...

Page 73: ...M is available in the same manner as the DAIA DAIB connection Figure 3 40 DTI Cable Connection via CN Connector Remote Site REMOTE PIM CSU MDF TWISTED PAIR CABLE DAIB BWB SHIELD TYPE MAX 656 ft 200 m CN DAIB DAIC MDF CN TB TA RB RA TO CSU MAIN PIM SEND RECEIVE 4 3 2 1 BA1 AA1 BA0 AA0 TB TA RB RA CN CONNECTOR 0 65Φ cable Note When the Remote PIM is directly connected without CSU maximum distance is...

Page 74: ...CHAPTER 3 ND 46550 E Page 66 Revision 2 0 2 4 MP Reset After mounting all DAIC cards and connecting between the main site and the remote site press the SW1 switch on the MP card ...

Page 75: ... DAIA RUN lamp is not flashing Abnormal operation of DAIA card Reset MB switch Down Up Down Check setting of SW1 1 FP No 1 2 FP No 2 3 FP No 3 0 4 F Not used If fault cannot be cleared replace card LINK lamp is not on Layer 2 link connection failure between DAIA and DAIB Check whether cable between DAIA and DAIB is correctly connected Refer to Chapter 3 Section 2 3 Reset MB switch Down Up Down RED...

Page 76: ...d Refer to Chapter 3 Section 2 3 Reset MB switch Down Up Down RED lamp is on PCM signal loss or Frame Alignment signal loss Check whether cable between DAIA and DAIB is correctly connected Refer to Chapter 3 Section 2 3 Reset MB switch of DAIA card on main site Down Up Down RMT lamp is on Remote alarm Check whether cable between DAIA and DAIB sending side is correctly connected Refer to Chapter 3 ...

Page 77: ...APTER 3 Section 2 3 Reset MB switch Down Up Down Check whether cable between DAIC cards is correctly connected Refer to CHAPTER 3 Section 2 3 RED lamp is on PCM signal loss or Frame Alignment signal loss Check whether cable between DAIC cards is correctly connected Refer to CHAPTER 3 Section 2 3 RMT lamp is on Remote alarm Check whether cable between DAIC cards sending side is correctly connected ...

Page 78: ...CHAPTER 4 ND 46550 E Page 70 Revision 2 0 This page is for your notes ...