ND-70348 (E)
CHAPTER 4
Page 687
Revision 3.0
ATDF
ATDF: Assignment of Time Difference Data
1. General
This command is required when there is time difference within the Netfusing link. The difference of time be-
tween nodes and the UCT (Universal Coordinated Time) are written in Network Data Memory (NDM) of the
Network Control Node (NCN) by using this command.
2. Precautions
1.
When “SIGN” = 0, “HOUR” and “MINUTE” are not available. Therefore, if SIGN = 0, the data will be
deleted.
2.
For more detail, see the “Netfusing System Manual” .
3. Data Entry Instructions
Enter the digits ranged from 0-12.
HOUR
REMARKS
FPC
Enter FPC which has Time difference
FUSION POINT
CODE
(FPC) 1-253
0
0
0
3
6
6
10
11
0
0
1 1
SIGN OF
DIFERRENCE
TIME
(SIGN) 0-2
HOUR OF
DIFERRENCE TIME
DATA (HOUR)
00-12
MINUTE OF
DIFERRENCE TIME
DATA (MINUTE)
00-59
SIGN
0=No Data
1=Plus (+)
2=Minus (-)
Enter the digits ranged from 0-59.
MINUTE