NDA-24299
CHAPTER 5
Page 65
Revision 1.0
DATA PROGRAMMING
Assignment of System Data
STEP 2:
ASYDL
Assign the self-Fusion Point Code (self-FPC) at each node. FPC ranges from 1 to 253. Use the
ASYDL command. (Index 512 b0-b7)
•
Index 512 self-Fusion Point Code
Assign a unique FPC for each node.
shows an example of FPC assignment.
Figure 5-6 Self-FPC Assignment
STEP 3:
ASYDL
Assign the data of DP (Dial Pulse) relay broadcasting to Fusion Link using the ASYDL command
(Index 527, b4): 0/1=DP relay broadcasting is invalid/valid.
Note:
Provided that the DP (10 or 20 pps) is set in the Signal Selecting for Outgoing C.O./Tie Line calls, assign
this data to bit4=1 (DP relay broadcasting is valid) when a call is originated at the node which doesn’t
accommodate C.O./Tie Line Trunk. The listed conditions for DTI circuit card have to be followed:
•
Firmware
PA-24DTR
SP3010:
Issue 11 or later
•
When PA-24DTR circuit card is used, turn the SW13/6C No.8 switch to OFF.
Figure 5-7 DP Signal Relay Broadcasting over Fusion Link (example)
NCN: Network Control Node
LN: Local Node
LN
LN
LN
LN
LN
LN
LN
LN
NCN
1
2
10
11
12
21
22
23
24
ASYDL Index 512 (b0-b7)
N EC
NE C
N EC
D TI
D TI
D TI
D TI
C O T
TLT
P rivate
N e tw ork
P ublic
N etw ork
FC C S
FC C S : F usion C all C ontrol S ig nal
FC C S
D P sig nal
D P signal
N od e A
N ode B
N ode C
C all O rigination to
C .O . line, Tie line
O riginating N ode
N od e accom m odating
the C .O ./Tie Line Trunk
E LC
Fusion N etw o rk