NDA-24299
CHAPTER 5
Page 115
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 3:
MBCT
Unbusy the connection trunk data assigned in the previous step, by using the MBCT command. This
is required for FCH, FGH trunks as well as speech channels.
STEP 4:
AFCH
Assign FCH number on an FCH circuit card basis. In the following example, FCHN=1 is assigned
for the FCH circuit card. For the FGH card, FCHN assignment is not necessary.
Figure 5-60 Assignment of FCHN (example)
Q-sig
PBX
FCH
FGH
DTI
ROUTER
Nail
Down C
onnect
ion
T1
speech
signaling
C_RT13
C_RT14
C_RT1
to CPU
FCHN=1
FCHEN: 000030
FCHN
1
FCHEN
000030
AFCH command display
Note:
This setting is a sample.