NDA-24299
CHAPTER 5
Page 85
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
shows a sample data assignment when FCH cards are located in the PIM 0 slot 4 and PIM 2 slot 11.
Figure 5-28 Assignment of FCH Number
The AFCH command display should look similar to
Figure 5-29 AFCH Command Display (example)
N E C
NEAX 2400 IMS
FCHN=2
LENS: 000270
FCHN=1
Data Assignment
PIM 0 Slot 04
LENS 011190
PIM 2 Slot 11
FCHN: 2 FCHEN: 01 0 19 0
FCHN: 1 FCHEN: 00 0 27 0
AFCH (Assignment of FCH Number for.....)
Slot No.
Dch (TK1)
Bch (TK23)
B ch (T K 1 )
B ch (T K 8 )
Bch (TK9)
Bch (TK16)
Bch (TK17)
20
Dch (TK2)
11
12
Group No.
19
23
22
21
DTI
FCH
Use "odd number" as the Group No. and "Level 0" for the FCHN.
example 2
(High-density slot 11)
example 1
(Regular-density slot 04)
FCHEN
xx x 19 0
MG U Gr Lv
Use this LENS.
odd No.
Lv=0
FCH card
PBX
FCHEN
xx x 27 0
MG U Gr Lv
Use this LENS.
04
05
01
27
03
00
02
Dch (TK1)
Bch (TK23)
Bch (TK1)
Dch (TK2)
Bch (TK8)
Bch (TK9)
Slot No.
Group No.
FCH
DTI
Extended G roup
U ntitled - E clipseCm d
File V iew H elp
A FC H (A ssignm ent of FCC H N um ber for.....)
FC HN
FC HN EN
W R T?
1
000270
Y
FCH N (1-255)
FCH EN
x x x x x x
M G : 0-7
U: 0-3
G roup: 00 - 31
Lv: 0-7
M G U G r L v
Note:
Before assigning FCHN, assign the trunk data using the ACTK command.