CHAPTER 3 SYSTEM DATA PROGRAMMING
Event Based CCIS Programming
Closed Numbering Plan Programming
DESCRIPTION
DATA
Assign LCR Group number to Area Code
Development Pattern.
•
(1)
(2)
YYYY=A000
0-3: LCR Group No.
4000-4007: Area Code Development
Pattern No.
Assign Area Code Development Pattern
number.
•
(1)
(2)
YYYY=4000-4007
X...XXX: Area Code (Max. 8 digits)
0000-0255: Route Pattern No.
Assign Route Pattern.
•
(1)
(2)
YYYY=0000-0255
1-4: 1st-4th Order
XXX ZZ
XXX: 000-255: LCR/TR Pattern No.
ZZ :
00-63: Trunk Route No.
Assign maximum number of sending
digits.
•
(1)
(2)
Y=0-7 Area Code Development Pattern
No. 0-7
X...XX: Area Code (Max. 8 digits)
01-79: Max number of sending digits