![NEC NEAX 1000 IVS System Manual Download Page 81](http://html.mh-extra.com/html/nec/neax-1000-ivs/neax-1000-ivs_system-manual_251362081.webp)
NDA-24219
CHAPTER
3
Page 67
Revision 2.0
NAP-200-007
Sheet 18/55
Termination of Cables on MDF
(b) Long Line (PN-AUCA) (see
Figure 007-11 MDF Cross Connection for Single Line Telephone (Long Line)
29
29
4
4
28
28
3
3
27
27
26
26
2
1
LEN0000
LEN0001
MDF
1
2
PIM0
P
PN-AUCA
LT01
LTC0
J
T1
R1
T0
R0
LEN0000 (No. 0)
LEN0001 (No. 1)
TO SINGLE LINE
TELEPHONE
(FOR LONG LINE)
1
R0
26
T0
2
R1
27
T1
3
28
4
29
(P)
26
T0
1
R0
27
T1
2
R1
28
3
29
4
LTC0 (J)
Note 1:
The PN-AUCA card can also be used as a DID Trunk card.
Note 2:
For the cross connection for the Power Failure Transfer (PFT), see item (12) in this NAP.
TO SINGLE LINE
TELEPHONE
(FOR LONG LINE)