![NEC N8551-28F Instruction Manual Download Page 28](http://html1.mh-extra.com/html/nec/n8551-28f/n8551-28f_instruction-manual_3976269028.webp)
10 Built-in AIT
5
When the SCSI bus can be set on the side of the basic processing unit, set the following on the
Built-In AIT.
• Transfer rate
: 40 MByte/second (max., synchronous)
• Data bus width
: 16 bits (Ultra Wide SCSI, LVD/SE)
• DISCONNECT/RECONNECT function
: Enable
For details, see the instruction manual provided with the basic processing unit.
Important
Set the maximum transfer rates as follows according to the number of devices connected to the
bus and the SCSI cable length.
SCSI ID
Maximum transfer
Data bus
Maximum cable Maximum number
rate (Mbyte/s)
width (bit)
length (m)
of devices
Single-ended
(SCSI host +
(LVD*)
number of
devices)
Ultra Wide SCSI
40
16
3 (-)
4
Ultra Wide SCSI
40
16
1.5 (-)
8
Ultra Wide SCSI
40
16
- (3)
16
Fast Wide SCSI
20
16
3 (3)
16
Wide SCSI
10
16
6 (3)
8
* When the SCSI host and all devices connected to the same bus are LVD-compatible.
Summary of Contents for N8551-28F
Page 18: ......
Page 21: ...Built in AIT 3 Bottom 1 2 3 4 5 6 7 8 ON DIP switch Switches which set the Built In AIT P 6...