856-128163-001-00 

5. 

Move the jumper pin for optional fan unit on mother board. Connect the two cooling fan cables (for 
optional fan unit) to the connectors on mother board. 

Take care to connect the cable to the proper connector. Otherwise, NEC ESMPRO will fail to monitor 
the server. 

 

 

6. 

Install the components you have removed. 

NOTE:

 For more information, refer to the User's Guide contained in NEC 

EXPRESSBUILDER DVD coming with your server. 

 

 

 

N8181-67 Redundant Fan Unit User's Guide 

856-128163-001-00 

 

Connector for standard fan unit (rear fan) 
(FAN1 connector) 
When connecting the optional fan, be sure 
to connect the rear cooling fan. 

Mother board 

Move the jumper pin upward to enable the redundant fan. 

Connector for optional 
fan unit (rear fan) 
(FAN2 connector) 