30
7.
After charging the BBU, make sure that the Current Write Policy (indicating write cache operation
status) is indicated as "Write Back."
Current Write Policy : Write Back
“Logical” tab
Default Write Policy : Write Back
“Properties” tab
Notice
The battery cell you have purchased is not charged at all. For such battery
cell, the [Current Write Policy] in [Properties] of [Logical] tab is indicated as
"Write Through" on MSM.
You can check the charged status of battery cell by selecting [Relative State
of Charge] or [Absolute State of Charge] in [Physical] tab
→
[Properties] on
MSM.
Tips
For details of the Write Policy, refer to the User’s Guide of the disk array
controller or MSM User’s Guide (online document in the CD-ROM coming with
the server).