Browser Control

 

 
Information and control can also be available through the HTTP browser control menu.   
In order to accomplish this, type:  

http://<the Monitor’s IP address>/pd_index.html 

Note that the LAN Power needs to be turned on in order for the display to be controlled while the units are off. 
All displays are set to the IP address 192.168.0.10 out of the box 
Communicating network PC needs to be on the same subnet as display that is being communicated with 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
NOTE: 

Menus on the left side of the above screenshot can be altered to control the display 
Menu above is consistent with the X464UN even though it states P553 on top 

 
 
 
 
 
 

 

Summary of Contents for MultiSync X464UN

Page 1: ...ption 150W max BTU s 511 82 BTU hour Quad Power Consumption 600W max Quad BTU s 2047 29 BTU hour NOTES This document is intended to be used as a reference guide to supply useful information for a design or installation It is not intended to be a step by step procedure for installation Any ceilings or walls must be strong enough to support the monitor and the installation must be in accordance with...

Page 2: ...uirements all models Dimensions below are minimum required for proper ventilation NOTE The ventilation space should not be covered or closed off at the front of the opening If for some reason the opening needs to be covered other means of ventilation will need to be incorporated into the design Contact NEC for design review and recommendations ...

Page 3: ...NEC Display Solutions of America Inc X464UN Installation Guide 46 LED LCD Display Rev 1 0 www necdisplay com X464UN Page 3 of 7 Display dimensions Note This product is not symmetrical ...

Page 4: ...NEC Display Solutions of America Inc X464UN Installation Guide 46 LED LCD Display Rev 1 0 www necdisplay com X464UN Page 4 of 7 Display dimensions cont ...

Page 5: ...64UN TMX4P and X464UN TMX9P Outer Dimensions with Peerless DS VW765 LAND Note KT 46UN OF2 Overframe Bezel Kit not pictured Input Panel Bottom o Red circles in the above interface connections signify the IN of that particular connector Blue circles in the above interface representations signify the OUT for that particular connector ...

Page 6: ...ous Communication Layer Transport Layer TCP Baud Rate 9600 bps IP Address 192 168 0 10 Default Data Length 8 bits Port Number 7142 Fixed Parity None Stop Bit 1 bit Communication Code Hex PC Control Connector D Sub 9P LAN Connector NOTE If so desired jumper Request to send and Clear to Send together on both ends of the cable to simplify cable connection These connections are not required The only c...

Page 7: ...itor s IP address pd_index html Note that the LAN Power needs to be turned on in order for the display to be controlled while the units are off All displays are set to the IP address 192 168 0 10 out of the box Communicating network PC needs to be on the same subnet as display that is being communicated with NOTE Menus on the left side of the above screenshot can be altered to control the display ...