background image

NEC Display Solutions

Video Wall Installation Guide

Additional PC-less advanced calibration capabilities

Display Wall Calibrator application high-end adjustment capabilities

Out of the Box Calibration

All displays are rigorously calibrated at a factory level for gamma, RGB, intensity, white 

point and uniformity to their native settings.  Calibration should not be needed out of the 

box if these are the settings that are needed for this particular installation.

PC-less display Self-Calibration

Through self-calibration, each monitor adjusts its settings according to the factory 

calibrated LUT, managed by the onboard SpectraView engine. PC-less calibration uses 

an MDSVSENSOR3 (located in the KT-LFD-CC2 Color Calibration Kit) directly connected to 

the dedicated monitor’s USB interface.

Connect the MDSVSENSOR3 to the display monitor’s USB1 (SENSOR) interface.

Menu:

 PICTURE  >  SPECTRAVIEW ENGINE  >  CALIBRATION  >  SET STAND-ALONE 

CALIBRATION  >  SELF CALIBRATION  >  SET

Note:

 For proper handling, this feature is recommended for video walls of up to 3x3 

displays, depending on accessibility. For most efficient and better overall calibration, 

larger video walls should be calibrated via the PC-based 

Display Wall Calibrator

 

application. 

In addition to the extensive calibration capabilities, two new high-end adjustment features lift the video wall calibration result to a new outstandingly high level. For further details please 

refer to the Display Wall Calibrator application users manual.

Corner Uniformity Correction

To perform the corner color matching on a single monitor.

PC-less White Copy function

Using the self-calibration feature, settings from a reference display are copied to each 

dedicated display in the video wall. Connect a MDSVSENSOR3 to the USB interface of the 

display to be adjusted. Using the sensor, measure a white test pattern on the reference 

display to readjust the display calibration.

Connect the MDSVSENSOR3 into the USB1 (SENSOR) interface of the display to be 

adjusted.

Place the sensor on the reference monitor showing a seeing a generated white test 

pattern.  Note that an external source is necessary for this.

Menu:

 PICTURE  >  SPECTRAVIEW ENGINE  >  CALIBRATION  >  SET STAND-ALONE 

CALIBRATION  >  WHITE COPY  >  SET

Note:

 To perform White Copy, self-calibration must be completed beforehand. For proper 

handling, this feature is recommended for video walls of up to 3x3 displays, depending 

on accessibility. For most efficient and better overall calibration, larger video walls should 

be calibrated via the PC-based 

Display Wall Calibrator

 application.

Uniformity Correction

To perform internal screen uniformity on a display, up to 10x10 measurement points can 

be defined within one monitor.

USB1 SENSOR

Summary of Contents for MultiSync UN462A

Page 1: ...ia DisplayPort HDMI or OPS can be distributed across the video wall by using the Tile Matrix function The UNxx2 displays provide several AUTO SETUP functions for simple and fast video wall setup and management To enable these functions to operate correctly it is necessary for DisplayPort HDMI and LAN cables to be daisy chained as illustrated below Primary monitor input output mapping For uncomprom...

Page 2: ...ayer and OPS Slot in PC when set to DisplayPort in OPTION SLOT2 CH SELECT TMDS Note that not all OPS devices support this internal connection 6 Connect a source to the primary monitor Connect your external PC to the DisplayPort1 HDMI1 or DVI interface on the first monitor Alternatively utilize an OPS Slot in PC or the integrated Media Player embedded into the first monitor for a neat and seamless ...

Page 3: ...ys pick up the same factory calibrated parameters according to the chosen preset but all presets can be altered via the SpectraView Engine menu if necessary 10 Choose input source for all displays To distribute the video signal from primary monitor across all monitors each successive monitor must have DisplayPort1 or HDMI1 as input Configure the remote control as ID 0 to manage all screens in para...

Page 4: ... calibration capabilities two new high end adjustment features lift the video wall calibration result to a new outstandingly high level For further details please refer to the Display Wall Calibrator application users manual Corner Uniformity Correction To perform the corner color matching on a single monitor PC less White Copy function Using the self calibration feature settings from a reference ...

Page 5: ...ca Inc All rights reserved Cat No 25 NEC 80 GL UN 346 Rev 08 23 19 NEC Display Solutions Video Wall Installation Guide Additional useful settings and application FRAME COMP and REVERSE SCAN To compensate for the vertical image shift often visible in fast moving pictures between Daisy Chained monitors FRAME COMP or REVERSE SCAN function can be selected in the OSD NaViSet Administrator 2 The all in ...

Reviews: