(27/38)
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: Everyday
bit 1: Every week
bit 2: Schedule Disable/Enable
* When bit0 and bit1 are '1', it behaves as Everyday.
EX.
FL setting
Schedule
Everyweek
Everyday
Schedule behavior
'0'-'0'(30h, 30h)
Schedule Disable
'0'-'1'(30h, 31h)
O Schedule
Disable
'0'-'2'(30h, 32h)
O
Schedule Disable
'0'-'3'(30h, 33h)
O O
Schedule
Disable
'0'-'4'(30h, 34h)
O
Once *Follow WD (Week setting)
'0'-'5'(30h, 35h)
O
O Everyday
'0'-'6'(30h, 36h)
O
O
Everyweek *Follow WD (Week setting)
'0'-'7'(30h,
37h)
O O O
Everyday
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies a data for confirmation.
Header Message
Check
code
Delimiter
SOH-'0'-'0'-'A'-'B'-'1'-'8' STX-'C'-'3'-'1'-'4'-ST-PG-ON HOURS-ON
MIN-OFF HOURS-OFF Min-NPUT-WD-FL-ETX
BCC CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller
'A' (41h): Monitor ID
LCD3210 must be ASCII 'A' (41h).
'B' (42h): Message type is "Command reply"
'1'-'8'(31h, 38h): Message length.
Message
STX (02h): Start of Message
'C'-'3'-'1'-'4' (43h, 33h, 31h, 34h): Schedule writes reply command
ST: Schedule Status command
0(30h):No error
1(31h):Error
PG-ON HOURS-ON MIN-OFF HOURS-OFF Min-NPUT-WD-FL: Schedule data
PG: Program No.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
ON_HOUR: Turn on time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): ON timer isn't set.