5-12
1.3. OSM control operation
Each OSM function is available by pressing the push-button switches (EXIT,
3
,
4
, -, +, NEXT, RESET)
allocated in the lower section of the front bezel (or the control PWB when a PWB unit only is furnished).
1.3.1. Switch functions
The basic functions of the respective push-button switches (or called the keys, but in the same meaning)
are described below.
In a mode where no OSM display is presented, the main menu of the OSM menu can be displayed when
any key out of UP, DOWN, -, and + is pressed.
Exit:
Menu Close, Sub menu exit
Control (
3
,
4
):
Menu Open, Cursor Move, Item Select
Adjust (+, -):
Menu Open, Adjust select item, Enter Sub menu
Next
Menu Open, Tag Select, Function execute
Reset:
Open reset menu, Sound Mute
1.3.2. Basic operational procedures
1) Press any key out of
3
or
4
or + or -, and confirm that a menu as shown below is displayed.
2) When the NEXT key is used, the selective tag moves to the right and the adjusting screen changes.
With the adjusting screen selected, use the keys
3
and
4
to select the adjusting item (simply “item”
hereafter) and set the adjusting value by the use of the keys - and +. To execute an automatic
adjustment function (CONTRAST AUTO ADJUST, AUTO ADJUST), press the key + or - in the state of
item highlight. Then, auto adjust are carried out.
When the adjusting item is present in TOOL or INFO., move to the selecting item with the NEXT key
and select the wanted item with the keys
3
and
4
. In the state that the wanted item is highlighted in
green, press the key + or - in order to get the adjusting screen displayed for each item.
3) When inspection is finished, press the EXIT key to withdraw from the OSM menu.