(85/104)
19.3 Input Name Reset
This command is used in order to reset the Input Name.
1) The controller requests the monitor to reset Input Name.
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-
'0'-'A'-'0'-'8'
STX-'C'-'A'-'0'-'4'-'0'-'2'-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'0'-'8'(30h, 38h): Message length (8bytes)
Message
STX (02h): Start of Message
'C'-'A'-'0'-'4' (43h, 41h, 30h, 34h): Input Name Command
'0'-'2' (30h. 32h): Reset
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3
“
Check code
”
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
2) The monitor replies result.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-
'B'-'0'-'A'
STX-'C'-'B'-'0'-'0'-'0'-'2'-ST-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to
‘
A
’
, replying monitor
’
s ID is
‘
1
’
.
'B' (42h): Message type is "Command reply".
'0'-'A'(30h, 41h): Message length (10bytes)
Message
STX (02h): Start of Message
'C'-'B'-'0'-'4' (43h, 42h, 30h, 34h): Input name Command
'0'-'2' (30h, 32h): Reset
ST: Status
00h (30h, 30h): No Error
01h (30h, 31h): Error
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.3
“
Check code
”
for a BCC calculation.
Delimiter
CR (0Dh): End of packet