Input / Output Panel                                                           

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

PC Control Codes                                                             

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function    

 

 

 

 

 

 

 

 

 

 

Code Data  

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER ON    

 

 

 

 

 

 

 

 

 

02H 

00H 

00H   00H   00H   02H 

 

 

 

 

 

POWER OFF    

 

 

 

 

 

 

 

 

 

02H   01H   00H   00H   00H   03H 

 

 

 

 

 

INPUT SELECT COMPUTER1 

 

 

 

 

 

02H   03H   00H   00H   02H   01H   01H   09H 

 

INPUT SELECT HDMI 1   

 

 

 

 

 

 

02H 

03H 

00H 

00H 

02H 

01H 

1AH 

22H 

 

INPUT SELECT HDMI 2   

 

 

 

 

 

 

02H 

03H 

00H 

00H 

02H 

01H 

12H 

AAH   

INPUT SELECT VIDEO    

 

 

 

 

 

 

02H   03H   00H   00H   02H   01H   06H   0EH 

 

INPUT SELECT VIEWER   

 

 

 

 

 

 

02H   03H   00H   00H   02H   01H   1FH   27H 

 

INPUT SELECT NETWORK   

 

 

 

 

 

02H   03H   00H   00H   02H   01H   20H   28H 

 

INPUT SELECT USB DISPLAY   

 

 

 

 

02H   03H   00H   00H   02H   01H   22H   2AH 

 

PICTURE MUTE ON    

 

 

 

 

 

 

 

02H   10H   00H   00H   00H   12H 

 

 

 

 

 

PICTURE MUTE OFF   

 

 

 

 

 

 

 

02H   11H   00H   00H   00H   13H 

 

 

 

 

 

SOUND MUTE ON    

 

 

 

 

 

 

 

02H   12H   00H   00H   00H   14H 

 

 

 

 

 

SOUND MUTE OFF    

 

 

 

 

 

 

 

02H   13H   00H   00H 

00H   15H 

 

 

 

 

 

PROJECTOR INFORMATION REQUEST  

 

 

00H   BFH   00H   00H 

01H   02H 

C2H   

 

 

ERROR STATUS REQUEST   

 

 

 

 

 

00H   88H   00H   00H 

00H   88H 

 

 

 

 

 

INFORMATION REQUEST 

 

 

 

 

 

 

03H   8AH   00H   00H 

00H   8DH   

 

 

 

 

Note:

 

Contact your NEC rep for codes not listed.

 

 

Cable Connection                                                             

Communication Protocol: 

Baud Rate:    

38400 bps  

 

 

 

 

 

 

 

 

 

 

 

 

Data Length:    

8 bits 

Parity:  

 

 

No Parity 

Stop Bit:   

 

One Bit 

X on/off:   

 

None 

Communications: Full duplex 

                                                                                                                   

 

PC Control Connector (D-Sub 9P)

 

 

 

 

 
NOTE 1 : 

Pins 1, 4, 6, and 9 are used inside the projector. 

NOTE 2:  

For long cable runs it is recommended to set communication speed within the projector to 9600 bps.

   

NOTE 3:   

Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection. 

1 2

3

4 5

6 7

8

9

To GND of PC

To RxD of PC

To TxD of PC

To CTS of PC

To RTS of PC

Summary of Contents for M402H

Page 1: ...he projection tables use the formulas below If the figures on the tables do not match the results of formulas use the figures in the table All calculations are based on a 16 10 aspect ratio Distances are in inches for millimeters multiply by 25 4 Distances may vary 5 Formulas The Projection Formulas use the image width for calculation For proper projection placement determine the image width for t...

Page 2: ...page 1 Diagonal Width W Height H inches inches inches inches 61 53 30 20 63 110 17 5 10 2 71 62 35 23 74 129 17 4 10 1 73 64 36 24 76 133 17 4 10 1 82 71 40 26 85 148 17 3 10 1 86 75 42 28 89 156 17 3 10 1 92 80 45 30 96 167 17 2 10 1 100 87 49 32 104 182 17 2 10 1 106 92 52 34 111 194 17 2 10 0 110 96 54 36 115 201 17 2 10 0 120 105 59 39 126 220 17 1 10 0 122 107 60 40 128 224 17 1 10 0 133 116 ...

Page 3: ...ca Inc M402H Installation Guide Ceiling Mounted and Desktop Rev 1 1 www necdisplay com M402H Page 3 of 6 Cabinet Dimensions The following drawings show the cabinet dimensions Dimensions are in inches For millimeters multiply by 25 4 ...

Page 4: ...c M402H Installation Guide Ceiling Mounted and Desktop Rev 1 1 www necdisplay com M402H Page 4 of 6 Cabinet Dimensions continued The following drawings show the cabinet dimensions Dimensions are in inches For millimeters multiply by 25 4 ...

Page 5: ...llation Guide Ceiling Mounted and Desktop Rev 1 1 www necdisplay com M402H Page 5 of 6 Optional Ceiling Mount Dimensions Model MP300CM The following drawings show the ceiling mount dimensions Dimensions are in inches For millimeters multiply by 25 4 ...

Page 6: ...0H 00H 12H PICTURE MUTE OFF 02H 11H 00H 00H 00H 13H SOUND MUTE ON 02H 12H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H PROJECTOR INFORMATION REQUEST 00H BFH 00H 00H 01H 02H C2H ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H INFORMATION REQUEST 03H 8AH 00H 00H 00H 8DH Note Contact your NEC rep for codes not listed Cable Connection Communication Protocol Baud Rate 38400 bps Data Length 8 bit...

Reviews: