background image

7

About the remote control on the system

S

a

fe

ty

P

re

ca

u

tio

n

s

O

p

e

ra

ti

n

g

In

st

ru

ct

io

n

s

C

ar

e

an

d

m

ain

te

n

an

ce

Tr

o

u

b

le

sh

o

o

tin

g

Tip

s

The remote control transmits the signals to the system.

Features of the Remote Control- Door Open

RESET

ON

TIME

a.m.
p.m.

OFF

TIME

a.m.
p.m.

Hr.

ON

OFF

SET

CANCEL

CHAOS

5

1

2

3

4

6

8

9

10

7

11

Heat pump model

Cooling model

OPERATION DISPLAY

Displays the operation conditions.

START/STOP BUTTON

Operation starts when this button is pressed
and stops when the button is pressed again.

OPERATION MODE SELECTION

BUTTON

Used to select the operation mode. (Refer to
page 8)

ON/OFF TIMER BUTTONS

Used to set the time of starting and stopping
operation.

TIME SETTING BUTTONS

Used to adjust the time.

TIMER SET/CANCEL BUTTONS

Used to set the timer when the desired time
is obtained and to cancel the Timer
operation.

AIRFLOW DIRECTION

START/STOP BUTTON

Used to stop or start louver movement and
set the desired up/down airflow direction.

SLEEP MODE AUTO BUTTON

Used to set Sleep Mode Auto operation.

AIR CIRCULATION BUTTON

Used to circulate the room air without
cooling or heating (turns indoor fan
on/off).

ROOM TEMPERATURE

CHECKING BUTTON

Used to check the room temperature.

RESET BUTTON

Used prior to resetting time or after
replacing batteries.

1

2

3

4

5

6

7

8

9

10

11

Flip-up door(opened)

Signal transmitter

Summary of Contents for LS-D2462CL

Page 1: ...ER S MANUAL Before using your air conditioner please read this manual carefully and keep it for future reference Prior to installation this air conditioning unit must be submitted for approval by the...

Page 2: ...the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all Contact the authorized Service technician for repair or maintenance...

Page 3: ...tioner must be grounded It may cause electrical shock if grounding is not perfect Do not install the unit at place where leakage of gas may occur and or in an explosive atmosphere In case of gas leaks...

Page 4: ...r appliances It will cause electrical shock or fire due to heat generation Do not operate with wet hand It will cause electrical shock Do not insert anything into the air inlet air outlet Since the fa...

Page 5: ...Safety Precautions Operating Instructions Care and maintenance Troubleshooting Tips 5...

Page 6: ...eave on installation stand which is damaged The unit may drop or fall down and cause an injury Do not insert hands through vanes when the air conditioner is operating It will cause an injury by the ro...

Page 7: ...ration mode Refer to page 8 ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation TIME SETTING BUTTONS Used to adjust the time TIMER SET CANCEL BUTTONS Used to set the timer whe...

Page 8: ...n this button is pressed and stops when the button is pressed again OPERATION MODE SELECTION BUTTON Used to select the operation mode ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperatu...

Page 9: ...System Some controls are located inside the indoor unit Open the front panel by lifting it up Slide Switch Operation Refer to page 16 FORCED OPERATION Used for operation when the remote control canno...

Page 10: ...tion mode is shifted in the direction of the arrow Close the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1...

Page 11: ...button is pressed the operation mode is shifted in the direction of the arrow Close the door on the remote control Set the temperature lower than the room temperature The temperature can be set within...

Page 12: ...or warmer you feel the more times up to two times you should press the button the set temperature will then be changed automatically During Auto Operation You cannot switch the indoor fan speed It ha...

Page 13: ...ion of the arrow Close the door on the remote control Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments Set the fan speed ag...

Page 14: ...imes The sleep mode is available for 1 to 7 times To alter the time period in steps of 1 hour press the Sleep Mode Button while aiming at air conditioner Setting the Time Press the Start Stop button T...

Page 15: ...ss the Start Stop button to start the unit Open the door on the remote control Press the Airflow Direction Start Stop button and the louvers will swing up and down Press the Airflow Direction Control...

Page 16: ...ower comes on again after a power failure Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions In case the air conditioner does not receiv...

Page 17: ...itched to the low LOW SPEED SOFT DRY SET TEMP 1 C SET TEMP 0 5 C ROOM TEMP INDOOR FAN COMP OPERATING START OPERATE OPERATE FOR 10MINS STOP FOR 3 MINS STOP FOR 7 MINS OPERATE FOR 10MINS SETTING FAN SPE...

Page 18: ...eat exchanger and panel vents may be professionally steam cleaned NOTE Dirtyorcloggedcoilswillreducetheoperating efficiencyofthesystemandcausehigher operatingcosts Never use any of the followings Wate...

Page 19: ...he air conditioner on Air circulation mode Reter to page 15 for 2 to 3 hours Turn off the circuit breaker and disconnect the plug Remove the batteries from the remote controll When the air conditioner...

Page 20: ...tains closed Do not let direct sunshine enter the room when the air conditioner is in operation Clean the air filter regularly Blockages in the air filter reduce the airflow and lower cooling and dehu...

Page 21: ...tarted Does not cool or heat effectively The air conditioner operation is noisy Remote controller display is faint or no display at all Crack sound is heard Is the air filter dirty See air filter clea...

Page 22: ...P NO 3828AR7109F Printed in Korea...

Reviews: