69
7.45.
“
TEMP_THRESHOLD
”
Control procedure
7.45.1. TEMP_THRESHOLD Control
CMD
Data1
Data2
Data3
Data4
Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x39)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x39) :
‘
TEMP_THRESHOLD
’
parameter
Value: 60 ~ 200 (range)
7.45.2. Current TEMP_THRESHOLD state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x39)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x39) :
‘
TEMP_THRESHOLD
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current TEMP_THRESHOLD getting value
60 ~ 200 (range)