1
External Control
for LCD8205
Revision
Date
History
Ver. 1.0
Dec.9.2008
The first edition.
Page 1: ...1 External Control for LCD8205 Revision Date History Ver 1 0 Dec 9 2008 The first edition...
Page 2: ...sed cable or null modem cable please refer to LCD 8205 User s Manual 3 Communication Parameter Item Setting Baud Rate 9600bps Data Bit 8bit Stop Bit 1bit Parity Bit None Stream Control None 3 1 Commun...
Page 3: ...2 p 16 Size p 12 p 16 Auto in progress p 12 p 16 Volume p 12 p 16 Balance p 12 p 16 Language p 12 p 16 OSD Tone p 12 p 16 BG Gray p 12 p 16 Fan Control p 12 p 16 Input p 12 p 16 Mute p 12 p 16 Cooling...
Page 4: ...p 41 MUTE p 42 SOUNDSTD p 43 AUTOVOLUME p 44 VOLUME p 45 BALANCE p 46 Equalizer p 47 ONHOUR p 48 ONMINUTE p 49 ONTIMEONOFF p 50 ONTIMEVOL p 51 OFFHOUR p 52 OFFMINUTE p 53 OFFTIMEONOFF p 54 HALFTONE p...
Page 5: ...elimiter Header Message Check code Delimiter SOH Reserved 0 Destination Source Message Type Message Length 1st 2nd 3rd 4th 5th 6th 7th Monitor Controller Header Message Check Code Delimiter Header Mes...
Page 6: ...current parameter from a monitor ASCII D 44h Get parameter reply ASCII E 45h Set parameter ASCII F 46h Set parameter reply 6th 7th bytes Message Length Specify the length of the message that follows...
Page 7: ...parameter reply is as follows Refer to section 5 2 4 Set parameter reply for more details 5 Command Command message format depends on each command Usually this command message is used for some non sli...
Page 8: ...h xor 36h xor 34h xor 03h 77h 5 1 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter 27 26 25 24 23 22 21 20 SOH D0 Reserved D1 Destination D2 Source D3 Type D4 Length...
Page 9: ...h 5 2 2 Get parameter reply The monitor replies with a current value and the status of the requested item operation code 1st byte STX Start of Message ASCII STX 02h 2nd 3rd bytes Result code These byt...
Page 10: ...OP code page Operation code page This OP code page data must be encoded to ASCII characters Ex The byte data 02h must be encoded to ASCII 0 and 2 30h and 32h Refer to 5 3 1 VCP OP code page OP code L...
Page 11: ...the monitor is encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A 41h Refer to 5 3 1 VCP OP code page OP code List 8th 9th bytes Type Operation type code ASCII 0 0 3...
Page 12: ...y Tint 00h 90h 0 100 User only Sharpness 00h 8Ch 87h 0 dull 100 sharp User only Color Temp NA NA User Normal Cool1 Cool2 Warm1 Warm2 NA R 00h 16h 0 100 User only G 00h 18h 0 100 User only B 00h 1Ah 0...
Page 13: ...nd Input 00h 60h 0 NOP 1 PC 3 DVI 4 HDMI 5 AV1 6 AV2 7 S VIDEO 12 Component Mute 00h 8Dh 0 2 UNMUTE 1 MUTE Cooling Fan Status 02h 7Bh 0 off 1 on Get only Read Out Temparature 02h 79h Get only Get curr...
Page 14: ...k Check Code Refer to the section 5 1 3 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 2 The monitor replies with current Brightness setting and capability to support this operat...
Page 15: ...en this byte is set to A the replying Monitor ID is 1 F 46h Message Type is Set parameter reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 0 30h 30h Result code No error...
Page 16: ...0 30h Message sender is the controller A 41h Message type is Command 0 4 30h 34h Message length is 4 bytes Message STX 02h Start of Message 0 C 30h 43h Command code is 0Ch as Save current settings ET...
Page 17: ...k code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor returns with the current power status Header SOH 01h Start Of Header 0 30h Reserved 0 30h Message receiver is the controller M...
Page 18: ...sage length is 12 bytes Message STX 02h Start of Message C 2 0 3 D 6 43h 32h 30h 33h 44h 36h power control command 0 0 0 1 30h 30h 30h 31h Power mode 0001 ON 0002 0003 Do not set 0004 OFF same as the...
Page 19: ...0h Result code No error C 2 0 3 D 6 43h 32h 30h 33h 44h 36h power control reply command The monitor replies same as power control command to the controller 0 0 0 1 30h 30h 30h 31h Power mode 0001 ON 0...
Page 20: ...20 6 Optional Commands 6 1 Communication Format for Optional Commands 6 1 1 Virtual Remote Control 6 1 2 Setting Parameters to Juno 6 1 3 Read Parameters from Juno...
Page 21: ...ESS 0 100 0x0E SCALEMODE 0 0x0F USERRED 0 100 0x10 USERGREEN 0 100 0x11 USERBLUE 0 100 0x16 MUTE 0 1 0x17 SOUNDSTD 0 4 0x18 AUTOVOLUME 0 1 0x1A VOLUME 0 100 0x1C BALANCE 0 100 0x1D EQ100HZ 0 20 0x1E E...
Page 22: ...Setting Value AV1 0 AV2 1 AV3 2 COMP1 6 DVI 9 DSUB 10 2 MAX_ILLUMINANCE Settings Setting Value Ambient Level by LUX 100 Ex Desired Ambient is 10000 Lux Setting is 100 10000 100 3 MIN_ILLUMINACE Setti...
Page 23: ...23 6 3 Control Examples at Master PC 6 3 1 Set Input Source to RGB Input 6 3 2 Read Power State...
Page 24: ...onitor ID 0x00 Default value 0x00 CMD 0xFE command data Parameter 0x00 Language parameter Value Data value 0 English 1 Spanish 2 Portuges 3 German 4 French 7 1 2 Language state read CMD Data1 Data2 Da...
Page 25: ...Current Source parameter Value Data value 0 AV1 1 AV2 2 AV3 6 COMPONENT 9 DVI 10 DSUB 7 2 2 Current Source state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Par...
Page 26: ...TUREMODE parameter Value Data value 0 User 1 dynamic 2 standard 3 movie 4 mild 7 3 2 Current Picture state read PC Digital video mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x...
Page 27: ...parameter Value Data value 0 User 1 cool2 2 cool1 3 normal 4 warm1 5 warm2 7 4 2 Current Color temperature state read PC Digital video mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor...
Page 28: ...CMD 0xFE command data Parameter 0x04 CONTRAST parameter Value 0 100 range 7 5 2 Current Contrast state read PC Digital video mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 C...
Page 29: ...IGHTNESS parameter Value Data value 0 User 1 dynamic 2 standard 3 movie 4 mild 7 6 2 Current Brightness state read PC Digital video mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID...
Page 30: ...command data Parameter 0x06 SHARPNESS parameter Value 0 100 step 5 range 7 7 2 Current Sharpness state read PC Digital video mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00...
Page 31: ...PICTUREMODE parameter Value Data value 0 User 1 dynamic 2 standard 3 movie 4 mild 7 8 2 Current Picture state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monit...
Page 32: ...RF_COLORTONE parameter Value Data value 1 cool2 2 cool1 3 normal 4 warm1 5 warm2 7 9 2 Current RF_COLORTONE state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 M...
Page 33: ...0xFE command data Parameter 0x09 RF_CONTRAST parameter Value 0 100 range 7 10 2 Current Contrast state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0...
Page 34: ...xFE command data Parameter 0x0A RF_BRIGHTNESS parameter Value 0 100 range 7 11 2 Current Brightness state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID...
Page 35: ...CMD 0xFE command data Parameter 0x0B RF_COLOR parameter Value 0 100 range 7 12 2 Current Color state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00...
Page 36: ...MD 0xFE command data Parameter 0x0C NTSC_TINT parameter Value 0 100 range 7 13 2 Current TINT state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00...
Page 37: ...0xFE command data Parameter 0x0D RF_SHARPNESS parameter Value 0 100 range 7 14 2 Current Sharpness state read AV S video Component mode CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID...
Page 38: ...5 4 3 6 14 9 7 4 3 8 Full Scn 9 1 1 7 15 2 Current Scale mode state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x0E Command 0xF4 Start bit Target 0x8...
Page 39: ...CMD 0xFE command data Parameter 0x0F USERRED parameter Value 0 100 range 7 16 2 Current USERRED state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x0F...
Page 40: ...MD 0xFE command data Parameter 0x10 USERGREEN parameter Value 0 100 range 7 17 2 Current USERGREEN state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x...
Page 41: ...CMD 0xFE command data Parameter 0x11 USERBLUE parameter Value 0 100 range 7 18 2 Current USERGREEN state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x...
Page 42: ...ommand data Parameter 0x16 MUTE parameter Value Data value 0 Mute Off 1 Mute On 7 19 2 Current Mute state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0...
Page 43: ...SOUNDSTD parameter Value Data value 0 User 1 Standard 2 Music 3 Movie 4 Speech 7 20 2 Current SOUNDSTD state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Paramet...
Page 44: ...FE command data Parameter 0x18 AUTOVOLUME parameter Value Data value 0 Off 1 On 7 21 2 Current AUTOVOLUME state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Param...
Page 45: ...0 CMD 0xFE command data Parameter 0x1A VOLUME parameter Value 0 100 range 7 22 2 Current VOLUME state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x1A...
Page 46: ...alue 0x00 CMD 0xFE command data Parameter 0x1C BALANCE parameter Value 0 100 range 7 23 2 Current BALANCE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Param...
Page 47: ...0Hz 0x1E EQ 300Hz 0x1F EQ 1KHz 0x20 EQ 3KHz 0x21 EQ 10KHz Value 0 20 range 7 24 2 Current BALANCE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter Com...
Page 48: ...alue 0x00 CMD 0xFE command data Parameter 0x22 ONHOUR parameter Value 0 23 range 7 25 2 Current ONHOUR state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Paramete...
Page 49: ...ue 0x00 CMD 0xFE command data Parameter 0x23 ONMINUTE parameter Value 0 59 range 7 26 2 Current ONMINUTE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parame...
Page 50: ...0xFE command data Parameter 0x24 ONTIMEONOFF parameter Value Data value 0 Disable 1 Enable 7 27 2 Current ONTIMEONOFF state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CM...
Page 51: ...e 0x00 CMD 0xFE command data Parameter 0x25 ONTIMEVOL parameter Value 0 100 range 7 28 2 Current ONTIMEVOL state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Para...
Page 52: ...alue 0x00 CMD 0xFE command data Parameter 0x26 OFFHOUR parameter Value 0 23 range 7 29 2 Current OFFHOUR state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parame...
Page 53: ...ue 0x00 CMD 0xFE command data Parameter 0x27 OFFMINUTE parameter Value 0 59 range 7 30 2 Current OFFMINUTE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Para...
Page 54: ...xFE command data Parameter 0x28 OFFTIMEONOFF parameter Value Data value 0 Disable 1 Enable 7 31 2 Current OFFTIMEONOFF state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 C...
Page 55: ...mand data Parameter 0x2A HALFTONE parameter Value Data value 0 Disable 1 Enable 7 32 2 Current HALFTONE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Paramet...
Page 56: ...nd data Parameter 0x2B BLUESCREEN parameter Value Data value 0 Disable 1 Enable 7 33 2 Current BLUESCREEN state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Param...
Page 57: ...nd data Parameter 0x2C PIXELSHIF_EN parameter Value Data value 0 Disable 1 Enable 7 34 2 Current PIXELSHIFT_EN state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE...
Page 58: ...command data Parameter 0x2D WIPER parameter Value Data value 0 Disable 1 Enable 7 35 2 Current WIPER state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter...
Page 59: ...x00 CMD 0xFE command data Parameter 0x2E BGGRAY parameter Value 0 7 range 7 36 2 Current BGGRAY state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x2E...
Page 60: ...0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x2F Command 0xF4 Start bit Target 0x89 Get bit Monitor ID 0x00 Default value 0x00 CMD 0xFE command data Parameter 0x2F POWER parameter CMD Data1 C...
Page 61: ...alue 0x00 CMD 0xFE command data Parameter 0x30 CURHOUR parameter Value 0 23 range 7 28 2 Current CURHOUR state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parame...
Page 62: ...ue 0x00 CMD 0xFE command data Parameter 0x31 CURMINUTE parameter Value 0 59 range 7 39 2 Current CURMINUTE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Para...
Page 63: ...ming varies by light ambient level Off Dimming varies by brightness of image settings MAX_ILLUMINANCE Max dimming ambient level Setting Value Ambient Level by LUX 100 MIN_ILLUMINANCE Min dimming ambie...
Page 64: ...E command data Parameter 0x33 MAX_ILLUMINANCE parameter Value 0 200 range 7 40 2 Current MAX_ILLUMINANCE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parame...
Page 65: ...E command data Parameter 0x34 MIN_ILLUMINANCE parameter Value 0 200 range 7 41 2 Current MIN_ILLUMINANCE state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parame...
Page 66: ...0xFE command data Parameter 0x35 AUTO_DIM parameter Value Data value 0 off 1 on 7 42 2 Current AUTO_DIM state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Paramet...
Page 67: ...ture of main sensor Reversed equation of TEMP_THRESHOLD to get real temperature CURTEMP_AUX Get current temperature of aux sensor Reversed equation of TEMP_THRESHOLD to get real temperature TEMP_THRES...
Page 68: ...meter CMD Data1 Command 0xF1 Value Command 0xF1 Start send bit Value Current Temperature getting value 7 44 CURTEMP_AUX Control procedure 7 44 1 Current aux Temperature state read CMD Data1 Data2 Data...
Page 69: ...E command data Parameter 0x39 TEMP_THRESHOLD parameter Value 60 200 range 7 45 2 Current TEMP_THRESHOLD state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Paramet...
Page 70: ...E command data Parameter 0x3A TEMP_HYSTERESIS parameter Value 2 20 range 7 46 2 Current TEMP_ HYSTERESIS state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parame...
Page 71: ...command data Parameter 0x3B FAN_CONTROL parameter Value Data value 1 on 2 auto 7 47 2 Current FAN_CONTROL state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Para...
Page 72: ...72 5 48 5 53...
Page 73: ...73...
Page 74: ...0x00 CMD 0xFE command data Parameter 0x3D SETX parameter Value 0 2 range 7 48 2 Current SETX state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x3D Co...
Page 75: ...0x00 CMD 0xFE command data Parameter 0x3E SETY parameter Value 0 2 range 7 49 2 Current SETY state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x3E Co...
Page 76: ...00 CMD 0xFE command data Parameter 0x3F SETXMAX parameter Value 1 3 range 7 50 2 Current SETXMAX state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x3F...
Page 77: ...00 CMD 0xFE command data Parameter 0x40 SETYMAX parameter Value 1 3 range 7 51 2 Current SETYMAX state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x40...
Page 78: ...CMD 0xFE command data Parameter 0x41 SETXGAP parameter Value 0 200 range 7 52 2 Current SETXGAP state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x41...
Page 79: ...CMD 0xFE command data Parameter 0x40 SETYGAP parameter Value 0 200 range 7 53 2 Current SETYGAP state read CMD Data1 Data2 Data3 Data4 Command 0xF4 Target 0x89 Monitor ID 0x00 CMD 0xFE Parameter 0x42...