4-6
6. Explanations of the factory mode
ON: Accumulated time during the reception of input signals (LED:
green)
OFF: Accumulated time in the power-saving mode (LED: amber)
* The above-mentioned accumulated time (hours running) is
reset when FACTORY PRESET or the RESET + “<”,”>” keys
is pushed during a display is executed.
T_ON: Total accumulated time during the reception of input
signals (LED: green)
T_OFF: Total accumulated time in the power-saving mode (LED:
amber)
* The above-mentioned accumulated time (hours running) is
not reset even when FACTORY PRESET is executed.
F/W VERSION: Firmware version
FACTORY PRESET: All data are reset to the initial values.
It is possible to adjust the gain values of R, G, B, respectively.
It is possible to adjust the offset values of R, G, B, respectively.
AUTO CONT: No. of auto-contrast control trials conducted by the
user
AUTO ALL: No. of auto-adjustment trials conducted by the user
HOTKEY SETTING: Set at ON (Europe version) for shipment
Set at OFF (Japan version and North
America version ) for shipment
LANGUAGE SETTING: Set at EN. (Europe and North America
version) for shipment
Set at JP. (Japan version)
AUTO CONTRAST: Auto-adjustments for the gain and the bias