INSTALLATION OF RACK MOUNT FITTINGS
Use the supplied rack mount fittings to mount the main unit in a rack.
Note that these fittings are for use with EIA standard racks.
1.
Remove the four (A) screws from the main unit.
2.
Fasten the rack mount fittings to the main unit
using the (A) screws which were removed.
3.
Fasten the unit to the rack with the supplied screws
(2 at the left and 2 at the right).
Rack mount fittings
Rack mount fittings installation dimensions
3.15"(80)
1.75"(44.5)
1.75"(44.5)
4-0.28"(7.2)X0.4"(10.3)
19" (482.6)
18.3" (465)
(Center of fitting mount holes)
Unit : inch (mm)
A
A
Vents
NOTE: Allow at least 30mm of space between the inside of
the rack and the left side of the IPS-4000/IPS-4000Q.
Ensure that there is sufficient ventilation and that vents are
unobstructed to prevent the build-up of heat inside the IPS-
4000/IPS-4000Q.
32