background image

SYSTEM CONFIGRATION GUIDE

 

– 

NEC Express5800/T110g-S / Liquid cooling model 

NEC Corporation 

Revision 6.0 

– October 23, 2015 

4

 

Model 

 

T110g-S 

Power 
Consumption 

(Max. Config, Idling) 

114 VA / 
97 Watt 

 

112 VA / 
98 Watt 

113 VA / 
96 Watt 

 

(Max. Config, 
Operating) 

192 VA / 
180 Watt 

206 VA / 
192 Watt 

219 VA / 
207 Watt 

183 VA / 
170 Watt 

Acoustic Noise   
(Sound Pressure 
Level) 

3

 

Minimum Config. 

29 dB 

 

 

 

Maximum Config. 

38 dB 

 

 

 

Dimensions (W x D x H ) 

98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in

 

Weight (Minimum / Maximum) 

8 kg / 11 kg, 17.64 lbs. / 24.25 lbs.

 

Temperature, Relative Humidity 
(non-condensing) 

Operating: 10° to 40° C / 50° to 104° F, 20 to 80% 
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% 

Regulatory and Safety 

FCC, CE, UL, CB, RoHS, BSMI, CCC, RCM, WEEE 

Operating Systems and Virtualization 
Software 

Microsoft® Windows Server® 2008 x86 Standard 
Microsoft® Windows Server® 2008 x86 Enterprise 
Microsoft® Windows Server® 2008 R2 Standard 
Microsoft® Windows Server® 2008 R2 Enterprise 
Microsoft® Windows Server® 2012 Standard 
Microsoft® Windows Server® 2012 Datacenter 
Microsoft® Windows Server® 2012 R2 Standard 
Microsoft® Windows Server® 2012 R2 Datacenter 

Red Hat Enterprise Linux 5.10 or later

 4

 

Red Hat Enterprise Linux 5.10 or later (EM64T)

 

4

 

Red Hat Enterprise Linux 6.5 or later

 

4

 

Red Hat Enterprise Linux 6.5 or later (EM64T)

 

Red Hat Enterprise Linux 7.0 or later

 

4

 

VMware ESXi™ 5.1 Update 1 or later 
VMware ESXi™ 5.5 Update 1 
VMware ESXi™ 6.0

 

1

 

Embedded SATA RAID controller is supported only on Windows operating systems. 

2

 

Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. 

3

 

Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating 
environment. 

4

 

For Linux support, contact your sales representative or go to the NEC website at: 

http://www.nec.com/global/prod/express/linux/index.html

 

   

Summary of Contents for Express5800/T110g-S

Page 1: ...ooling model Introduction This document contains product and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server October 23 2015 Revision 6 0 NEC Corporation ...

Page 2: ...uration 24 5 Internal Optical Drive 27 6 Internal RDX Drive 27 7 PCI Card 27 7 1 Network Interface Controller 27 7 2 SAS Controller 28 7 3 Serial Port Adapter 28 8 Other Add in Components 29 8 1 Trusted Platform Module Kit 29 8 2 Internal Flash Memory 29 8 3 Flash FDD 29 8 4 Input Devices 29 9 Add on Components 30 9 1 Server Management License 30 9 2 Rack Conversion Kit 30 9 3 Dust Proof Kit 30 9 ...

Page 3: ... 4 x 8 GB Internal Storage Standard Capacity 0 GB Maximum Capacity 8 TB 2 x 4 TB Disk Controller SATA 6Gb s Integrated RAID SATA RAID 0 1 10 Standard RAID 5 6 50 60 Optional SAS RAID 0 1 5 6 10 50 60 Optional Hot Plug Supported When using N8154 59F or N8154 59F 56F Optical Disk Drive Optional 3 5 inch Media Bays 1 Disk Drive Bays 2 or 4 or 6 Expansion Slots Total 4 slots available 1 PCIe 3 0 x16 x...

Page 4: ...s Server 2008 x86 Enterprise Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter Red Hat Enterprise Linux 5 10 or later 4 Red Hat Enterprise Linux 5 10 or later EM64T 4 Red Hat Enterprise Linux 6 5 or...

Page 5: ...ical Disk Drive C Hard Drive Activity LED H 3 5 inch Media Bay D System Status LED I Drive Bay Cover Key E USB 3 0 Connector J Drive Bay Cover Rear Views Legend A Serial Port A Connector F USB 3 0 Connectors B VGA Connector G Management LAN Connector C BMC Reset Switch H Data LAN Connectors D Dump NMI Switch I PCI Slots Low Profile E USB 2 0 Connectors J AC Inlet A B C D E F H I J G B C D E F G H ...

Page 6: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110g S Liquid cooling model NEC Corporation Revision 6 0 October 23 2015 6 Dimensions mm Standard Bezel Tower Orientation Desktop Orientation ...

Page 7: ...SYSTEM CONFIGRATION GUIDE NEC Express5800 T110g S Liquid cooling model NEC Corporation Revision 6 0 October 23 2015 7 Dust Proof Bezel Tower Orientation Desktop Orientation ...

Page 8: ...n Diagram Legend Minimum requirement components Standard components Expansion Slots Legend 1 PCIe 2 0 x1 x8 connector Low Profile up to 168mm length 2 PCIe 2 0 x1 x8 connector Low Profile up to 168mm length 3 PCIe 3 0 x16 x16 connector Low Profile up to 168mm length 4 PCIe 2 0 x4 x8 connector Low Profile up to 168mm length 1 2 3 4 ...

Page 9: ...C 4T 8 MB N8101 626F Xeon E3 1231 v3 Processor Kit Intel Xeon Processor E3 1231 v3 3 40 GHz 4C 8T 8 MB N8101 741F Xeon E3 1275L v3 Processor Kit Intel Xeon Processor E3 1275L v3 2 70 GHz 4C 8T 8 MB N8101 742F NOTE One processor kit from above must be installed 3 Memory Available slots 4 Product Name Description Part Number 4GB DDR3L 1600 UNB Memory Kit 4GB Unbuffered ECC DIMM DDR3L 1600 PC3L 12800...

Page 10: ... GB 32 GB Microsoft Windows Server 2008 Enterprise 64 GB 32 GB Microsoft Windows Server 2008 R2 Enterprise 1 2 TB 32 GB Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter 1 4 TB 32 GB Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 16 GB 16 GB Red Hat Enterprise Linux 5 EM...

Page 11: ...two kinds of drives can be mixed in a system All drives within a RAID array should be of the same capacity and rotation speed Mixing SAS and SATA hard drives in the same drive cage is not supported All drives within a drive cage should be of the same rotation speed Non RAID RAID 5 0 MB Cache 1GB Cache Battery 512 MB Cache Refer to 4 2 1 Refer to 4 2 3 Refer to 4 2 5 Refer to 4 2 6 RAID 0 1 SATA SA...

Page 12: ...iguration Embedded SATA RAID controller is supported only on limited OS For more details please see OS Support Matrix for PCI Cards and Embedded Controllers All hard drives within a RAID array should be of the same capacity and rotation speed All drives within a RAID array should be of the same capacity and rotation speed Non RAID 0 MB Cache 512 MB Cache Refer to 4 3 1 Refer to 4 3 3 Refer to 4 3 ...

Page 13: ...pm N8150 454 NOTE Hot plug insertion removal is not supported with the embedded SATA non RAID controller 4 2 2 Up to four Drives with Embedded SATA RAID Controller Category Product Name Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb s SATA RAID0 1 10 capable Standard Cable Internal SATA Cable miniSAS to miniSAS Standard Drive Cage Required 2 5 inch Drive Cage 4 x 2 5 in...

Page 14: ... HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB 15K Hot Plug 2 5 inch SAS HDD 1x 300 GB SAS HDD 2 5 inch 6Gb ...

Page 15: ...000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB 15K Hot Plug 2 5 inch SAS HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 450 450GB 15K Hot Plug ...

Page 16: ...b s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB 15K Hot Plug 2 5 inch SAS HDD 1x 300 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 450 450GB 15K Ho...

Page 17: ...10 000 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB 15K Hot P...

Page 18: ...HDD 1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb ...

Page 19: ...1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15...

Page 20: ... N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB 15K Hot Plug 2 5 in...

Page 21: ...0 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5 inch SAS HDD 1x 146 5 GB SAS HDD 2 5 inch 6Gb s 15 000 rpm N8150 449 300GB 15K Hot Plug 2...

Page 22: ... rpm N8150 444 450GB 10K Hot Plug 2 5 inch SAS HDD 1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 448 146 5GB 15K Hot Plug 2 5...

Page 23: ... 1 x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 444 450GB 10K Hot Plug 2 5 inch SAS HDD 1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x 600 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 446 900GB 10K Hot Plug 2 5 inch SAS HDD 1x 900 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 447 1 2TB 10K Hot Plug 2 5 inch SAS HDD 1x 1 2TB SAS HDD 2 5 inch 6Gb s 10 0...

Page 24: ...d SATA RAID Controller Category Product Name Description Part Number Storage Controller Embedded SATA Controller 4x 6Gb s SATA RAID0 1 10 capable Standard Cable Required Internal SATA Cable mini SAS to 2x Single SATA K410 278 00 Drive Cage Required 3 5 inch Drive Cage 2 x 3 5 inch non hot plug fixed drive bays N8154 65F Drive 2 slots available 500GB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 500 GB S...

Page 25: ...uld be of the same capacity 4 3 4 Up to two Drives with RAID 0 1 Controller with 512 MB Cache Category Product Name Description Part Number Storage Controller Required RAID Controller 512MB RAID 0 1 LSI MegaRAID SAS 9272 8i RAID0 1 10 512 MB Int 8 PCIe 3 0 x8 SAS 6Gb s SATA 6Gb s N8103 172 RAID BBU Recommended RAID Battery Backup Unit for LSI MegaRAID SAS 9272 8i N8103 155 Cable Required Internal ...

Page 26: ... SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 463 4TB 7 2K non Hot Plug 3 5 inch SATA HDD 1 x 4 TB SATA HDD 3 5 inch 6Gb s 7 200 rpm N8150 464 2 5 inch Drive 2 slots available SAS HDD 300GB 10K Hot Plug 2 5 inch SAS HDD 1 x 300 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 444 450GB 10K Hot Plug 2 5 inch SAS HDD 1 x 450 GB SAS HDD 2 5 inch 6Gb s 10 000 rpm N8150 445 600GB 10K Hot Plug 2 5 inch SAS HDD 1 x...

Page 27: ...x USB 2 0 cable for N8160 97F 24cm K410 351 00 NOTE Up to 1 optical drive can be connected N8151 121 Optical Drive Bay Cover must be installed when not installing any internal optical drives 6 Internal RDX Drive Category Product Name Description Part Number Controller Internal USB Controller 1 x USB port or 1 x pin header for front panel USB Standard Cable Required Internal USB cable 1x Internal U...

Page 28: ...erface Operating Systems GbE Embedded 1GbE NIC Windows Server 2008 R2 Windows Serer 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 VMware N8104 138 Windows Server 2008 R2 Windows Serer 2012 Windows Server 2012 R2 Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 VMware N8104 132 Windows Server 2008 R2 Windows Serer 2012 Windows Server 2012 R2 Red Hat Enterpri...

Page 29: ...ry Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without DVD media NOTE Before use software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory The following operations can be performed with the flash memory Installation of Windows server with express setup Installation of Starter Pack the package of NEC qualified drivers and system setting tools ...

Page 30: ...of the remote terminals PC server as if accessing the local drives N8115 04 NOTE Remote KVM and remote media features are not available for virtual machines 9 2 Rack Conversion Kit Product Name Description Part Number Rack Conversion Kit Convert to 3U form factor N8143 94 9 3 Dust Proof Kit The server supports the dust resistant feature Choose the following kit to install the system in dusty place...

Page 31: ...orporation Revision 6 0 October 23 2015 31 9 5 Medium and Cartridge Category Product Name Drive supported Part Number RDX HDD RDX Cartridge 320GB N8151 105 N8153 01 RDX Cartridge 500GB N8151 105 N8153 02 RDX Cartridge 1TB N8151 105 N8153 03 RDX Cartridge 2TB N8151 105 N8153 09 ...

Page 32: ...sed screen OS console Remote KVM Video Record Remote control via LAN Remote reset power on off dump Remote Power Capping BIOS BMC FW update Remote BIOS setup partial configuration only OS shutdown 3 3 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Scheduling without UPS require NEC ESMPRO Manager 3 3 Maintenance ...

Page 33: ... 0 1 N8103 173 RAID Controller 512MB RAID 0 1 5 6 N8103 174 RAID Controller 1GB RAID 0 1 5 6 N8103 168 RAID Controller 1GB RAID 0 1 5 6 N8104 138 1000BASE T Adapter 1ch N8104 132 Quad Port 1000BASE T Adapter N8104 133 1000BASE T Adapter 2ch Supported PCI cards and Installable Slots Slots Part Number Product Name 1 2 3 4 N8103 142 SAS Controller N8103 171 RAID Controller 0MB RAID 0 1 N8103 172 RAID...

Page 34: ...e registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for technical or editorial...

Page 35: ...OM drive N8160 91 RDX Cartridge 2TB N8153 08 RDX Cartridge SSD 128GB N8153 06 RDX Cartridge SSD 256GB N8153 07 5 0 April 17 2015 Others Added ESXi 6 to the list of operating system supported 4 0 January 28 2015 Part number changed Flash FDD N8160 96 3 0 November 21 2014 Discontinued product deleted 2GB DDR3L 1600 UNB Memory Kit N8102 523F 2 0 October 16 2014 Discontinued product deleted RDX Cartri...

Reviews: