background image

CONFIGURATION GUIDE

 

– 

NEC Express5800/A2040c, A2020c, A2010c, A1040c 

 

NEC Corporation 

Rev.2.0 

–Sep. 2015

 

47 

8.4  Cable Arm 

With this component at rear side of the server, various cables are compactly combined. 

Product Name/Description 

Part Number 

Cable Arm 

70mm

 

Including slide rail attachment 
Able to combine around 18 cables (except AC Power Cable, such as LAN, FC and USB) 

NE3343-H001 

Cable Arm 

110mm

 

Including slide rail attachment 

Able to combine around 32 cables (except AC Power Cable, such as LAN, FC and USB) 

NE3343-H002 

NOTE: 

 

Need to use Slide Rail Attachment to use Cable Arm. This makes server depth longer, as shown in the 
Dimensions. 

 

For calculation, considering LAN (UTP: without shield) is 

φ5mm in diameter at average, 1x FC cable 

corresponds to 1x LAN cable, 1x SAS cable corresponds to 2x LAN cables, 1x SUV cable corresponds 
to 4x LAN cables and 1 x USB Cable corresponds to 1 x LAN cable. 

 

Table for quick reference: 

 

Model 

 

A2040c/A2020c/A2010c 

A1040c 

 

Cable Arm 

(70mm) 

Cable Arm 

(110mm) 

Cable Arm 

(70mm) 

Cable Arm 

(110mm) 

 

Max. cable capacity 

 

(by no. of LAN cable)   

18

 

32 

18 

32 

Management LAN 
(mandatory required) 

SUV Cable

 *1 

(by no. of LAN cable) 

Open cable capacity 
(by no. of LAN cable) 

12 

26 

13 

27 

1

 

1 x SUV Cable corresponds to 4 x LAN cable. 

 

Remarks: 

 

With Cable Arm (110mm), the unit with more than 670mm in depth (from the front) cannot be located on 
top of the server. Otherwise, need to have 1U between the unit and the server.   

 

(Please refer to the illustoratinos below.) 

 

 

 

Summary of Contents for Express5800/A1040c

Page 1: ...uct and configuration information that will enable you to configure your system The guide will ensure fast and proper configuration of your NEC Express5800 server The available models depend on sales regions For details please contact your region s sales representative Sep 2015 Rev 2 0 NEC Corporation ...

Page 2: ... Base Models 14 1 1 A2040c 14 1 2 A2020c 15 1 3 A2010c 16 1 4 A1040c 17 1 5 COPT 18 2 CPU 19 3 Memory 21 3 1 Memory Riser Card 21 3 2 Memory Configuration 22 4 Internal Disk Drives 28 4 1 RAID Configuration 28 4 2 Internal Drive Configuration 30 5 Optical Drive 35 6 PCI Card 36 6 1 Network Interface Controller 36 6 2 PCIe SSD Adapter 39 6 3 External Storage Controller 40 7 Other Add in Components ...

Page 3: ...NCES 50 CPU 50 Memory 50 Internal Drive 56 Connection to RDX USB by Device Expansion Unit 58 Server Management 59 PCI Slot Available Slots and Installation Limitations 60 PCI Card Priority Order of Installation 70 RAS Feature Matrix per OS 74 Copyright Notice and Liability Disclaimer 78 REVISION HISTORY 79 ...

Page 4: ... 50 60Hz 3Hz 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 2319VA 2273W 2258VA 2213W 2217VA 2173W 2115VA 2073W 2115VA 2073W 2115VA 2073W 2319VA 2273W 2217VA 2173W 2370VA 2323W 2309VA 2263W 2268VA 2223W 2166VA 2123W 2166VA 2123W 2166VA 2123W 2370VA 2323W 2268VA 2223W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 126...

Page 5: ... 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 1298VA 1272W 2185VA 2141W 2136VA 2093W 2103VA 2061W 2021VA 1981W 2021VA 1981W 2021VA 1981W 2185VA 2141W 2103VA 2061W 2236VA 2191W 2187VA 2143W 2154VA 2111W 2072VA 2031W 2072VA 2031W 2072VA 2031W 2236VA 2191W 2154VA 2111W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 1265W 1291VA 12...

Page 6: ...Hz 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 929VA 911W 1381VA 1354W 1357VA 1330W 1340VA 1314W 1300VA 1274W 1300VA 1274W 1300VA 1274W 1381VA 1354W 1340VA 1314W 1432VA 1404W 1408VA 1380W 1391VA 1364W 1351VA 1324W 1351VA 1324W 1351VA 1324W 1432VA 1404W 1391VA 1364W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 925VA 906W 1374VA 1346W ...

Page 7: ...1291VA 1265W 1291VA 1265W 2311VA 2265W 2250VA 2205W 2209VA 2165W 2107VA 2065W 2107VA 2065W 2107VA 2065W 2311VA 2265W 2209VA 2165W 2362VA 2315W 2301VA 2255W 2260VA 2215W 2158VA 2115W 2158VA 2115W 2158VA 2115W 2362VA 2315W 2260VA 2215W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 1285VA 1259W 2300VA 2254W 2239VA 2194W 2198VA 2154W 2096VA 2054W 2096VA 205...

Page 8: ...N LED N NMI Button C PCI LED O RESET Button D MEM LED P UID LED E CPU LED Q UID Button F VLT TMP LED Voltage Temperature R SYSTEM POWER LED G CNFG LED Configuration S SYSTEM POWER Button H MISC LED T USB Connectors I NEXT LED U VGA Connector J NEXT Button V Optical Drive Bay K DISK Access LED W 2 5 inch Drive Bays L SYSTEM STATUS LED X Slide Tag A B P Q R E G I D F J KL M N BC H O S T U V W X ...

Page 9: ...D 1 K MGB 2 Maintenance LAN Connector 1 D PCI Slots Low Profile L MGB 2 Management LAN Connector 1 E UID Button M SUVCable Connector 2 F MGB 1 RESET Button N Power Supply Unit G MGB 2 RESET Button 1 O AC POWER LED H USB Connector P AC Inlet 1 Not applicable with A1040c 2 2x USB Connectors and 1x Serial Port and 1 x VGA Connector can be connected through SUV Cable attached to Base Models 2m length ...

Page 10: ...NEC Express5800 A2040c A2020c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 10 Dimensions mm A2040c A2020c A2010c A1040c In case of using slide rail attachment cable arm in use The above illustrations includes inner rail ...

Page 11: ...C Express5800 A2040c A2020c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 11 Configuration Diagram A2040c Legend Standard components Minimum required components A2020c Legend Standard components Minimum required components ...

Page 12: ...ON GUIDE NEC Express5800 A2040c A2020c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 12 A2010c Legend Standard components Minimum required components A1040c Legend Standard components Minimum required components ...

Page 13: ... Slot 15 PCI Express 3 0 x8 lane x8 socket Slot 16 PCI Express 3 0 x8 lane x8 socket NOTE For all PCI slots Low Profile 167 6mm in length PCI slot performance x4 lane for Slot 8 and 9 x8 lane for the others Hot Plug supported Slot 2 to 9 8 slots not available with A1040c For A2040c Slot 1 to 9 are available in case of 2CPU configuration Slot 1 to 13 are available in case of 3CPU configuration and ...

Page 14: ...400 091F NOTE The base model must be ordered with processor kits memory riser cards memory kit power supply units Power cables should be ordered as well for each geo Front Bezel and Cable Arm are not attached need to be ordered separately if required Number of the available PCI Slots and Memory Riser Card depends on the number of CPUs Available PCI Slots and Maximum No of Memory Riser Card No of C...

Page 15: ...0 074F NEC Express5800 A2020c 10C E7 4820v3 2x Intel Xeon Processor E7 4820v3 1 90 GHz 10C 20T 25MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 075F NEC Express5800 A2020c 8C E7 4809v3 2x Intel Xeon Processor E7 4809v3 2 00 GHz 8C 16T 20MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 076F NEC Express5800 A2020c 10C E7 8891v3 2x Intel Xeon Processor E7 8891v3 2 80 GHz 10C 20T 4...

Page 16: ...S NE3400 084F NEC Express5800 A2010c 10C E7 4820v3 1x Intel Xeon Processor E7 4820v3 1 90 GHz 10C 20T 25MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 085F NEC Express5800 A2010c 8C E7 4809v3 1x Intel Xeon Processor E7 4809v3 2 00 GHz 8C 16T 20MB no RAM no HDD no ODD no Power Supply Unit no OS NE3400 086F NEC Express5800 A2010c 10C E7 8891v3 1x Intel Xeon Processor E7 8891v3 2 80 GHz 10...

Page 17: ...ser cards memory kit power supply units Power cables should be ordered as well for each geo Front Bezel and Cable Arm are not attached need to be ordered separately if required Number of the available PCI Slots and Memory Riser Card depends on the number of CPUs Available PCI Slots and Maximum No of Memory Riser Card No of CPU Max No of Memory Riser Available PCI Slots 1 2 3 4 5 6 7 8 9 10 11 12 1...

Page 18: ...cket license based software please enable CPU core at the CPU socket on which the software is operating Software license is required for the socket with at least one enabled CPU core Depending on the OS the server may need to be rebooted to enable CPU cores Remarks to use COPT under Linux environment When using Fibre Channel Controller 16Gbps NE3390 157A 158A need to enable enough number of CPU co...

Page 19: ...ar items NE3301 H012F Xeon E7 8870v3 Processor Kit 1x Intel Xeon Processor E7 8870v3 2 10 GHz 18C 36T 45MB NE3301 H013F Xeon E7 4850v3 Processor Kit 1x Intel Xeon Processor E7 4850v3 2 20 GHz 14C 28T 35MB NE3301 H014F Xeon E7 4820v3 Processor Kit 1x Intel Xeon Processor E7 4820v3 1 90 GHz 10C 20T 25MB NE3301 H015F Xeon E7 4809v3 Processor Kit 1x Intel Xeon Processor E7 4809v3 2 00 GHz 8C 16T 20MB ...

Page 20: ...ntel Virtualization Technology Technology to provide hardware CPU support for processor virtualization Security Execute Disable Technology to avoid the execution of malware utilizing buffer over flow error The maximum number of logical processors supported by OS See the table below for the maximum number of logical processors that you can actually use on your system Maximum Number of Logical Proce...

Page 21: ... slots Hot plug supoprted NE3402 H003 NOTE A2040c 1 to 2 MRs can be installed per CPU thus up to 8 MRs can be installed with 4CPU configuration A2020c Up to 8 MRs can be installed A2010c Up to 4 MRs can be installed Not pre installed in Base Model At least one MR needs to be ordered Cover for Hot plug is attached For A1040c Product Name Description Part Number Memory Riser Card Module with 8x DIMM...

Page 22: ...Mode Lockstep Mode Memory Rank Sparing and Memory Mirroring Memory Configuration Feature Comparison See the table below for feature comparisons of memory configurations supported Independent Mode only Memory Rank Sparing under Independent Mode Memory Mirroring under Independent Mode Summary In case of correctable errors switching to spare memory rank Redundant memory having the same data Available...

Page 23: ...RDIMM Data Correction ECC DDDC Notes RDIMM and LRDIMM cannot be mixed Need to order memory for sparing Need to order memory for mirroring 3 4 memory channels per Memory Riser Card 4 All DIMMs have the same capacity Customized Configuration Service at the Server Delivery Product Name Description Part Number Customized Service Distribution Mode for COPT NE3300 SV101 NOTE This is the service product ...

Page 24: ... H042F Load Reduced DIMM LRDIMM 64GB MEM 2x32GB LRDIMM CTO 2x 32GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different from other regular items NE3302 H043F 128GB MEM 2x64GB LRDIMM CTO 2x 64GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different from other regular items NE3302 H...

Page 25: ...042F Load Reduced DIMM LRDIMM 64GB MEM 2x32GB LRDIMM CTO 2x 32GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different from other regular items NE3302 H043F 128GB MEM 2x64GB LRDIMM CTO 2x 64GB Load Reduced DIMM DDR4 2133 PC4 2133 ECC Note This is CTO cattegoraized item lead time for delivery is different from other regular items NE3302 H04...

Page 26: ...Need to order at least 1 set 4x DIMM RDIMM and LRDIMM cannot be mixed in a server 1 spare rank available with 8GB RDIMM 1 or 2 spare rank available with 16GB RDIMM Logical Memory Capacity at Memory Rnak Sparing ex using the same capacity DIMMs No of DIMM Physical Memory Capacity 8GB RDIMM 16GB RDIMM 1 Spare Rank 1 Spare Rank 2 Spare Ranks 4 16GB 48GB 32GB 8 32GB 96GB 64GB 12 48GB 144GB 96GB 16 64G...

Page 27: ...guration Mode Memory Type No of DIMMs per 1CPU Clock 1 2V Xeon E7 8890v3 E7 8880v3 E7 8870v3 E7 4850v3 E7 4820v3 E7 4809v3 E7 8891v3 E7 8893v3 Independent Mode RDIMM 8 16 32GB Up to 16 1600 MHz LRDIMM 32 64GB Up to 16 1600 MHz Lockstep Mode RDIMM 8 16 32GB Up to 16 1866 MHz LRDIMM 32 64GB Up to 16 1600 MHz Maximum Memory Capacity The available memory capacity depends on the OS as the following lis...

Page 28: ...o of Drive 4 Y NOTE Needs to order RAID Controller to configure internal drives For RAID Configuration same type of internal drives need to be ordered within one RAID group pack Multiple RAID group can be configured by one RAID Controller In case of RAID1 4 groups at maximum Different capacity rotation speed disk type of internal drives can be mixed among different RAID groups When configuring hot...

Page 29: ...010c A1040c NEC Corporation Rev 2 0 Sep 2015 29 1x RAID Controller Configuration 2x RAID Controller Configuration 4 2 1 SAS HDD SSD 2GB Cache Flash 1GB Cache Flash 4 2 2 4 2 3 SAS HDD SSD 2GB Cache Flash SAS HDD SSD 1GB Cache Flash 4 2 4 5 年目 SAS HDD SSD ...

Page 30: ...xing these drives please refer to the section Internal Disk at References RAID 0 1 5 6 10 can be configured at BTO Configuration For RAID 50 60 need to configure after the delivery With 2 RAID Controller configuration the 2 nd RAID Controller and 5 th and more HDDs cannot be configured at BTO Configuration With 2 RAID Controller configuration RAID cannot be configured between internal drives under...

Page 31: ... 12Gb s 10 000 rpm 512B sector NE3350 479M 600GB HDD 1x600 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 481M 900GB HDD 1x 900 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 12Gb ...

Page 32: ...Gb s 10 000 rpm 512B sector NE3350 479M 600GB HDD 1x600 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 481M 900GB HDD 1x 900 GB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 12Gb s 1...

Page 33: ...350 482M 1 2TB HDD 1x 1 2 TB SAS HDD 2 5 inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 486M 600GB HDD 1x 600 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 518M SAS SSD eMLC 200GB SSD CTO 1x 200 GB SAS SSD eMLC 2 5 inch 12Gb s 512B sect...

Page 34: ...inch 12Gb s 10 000 rpm 512B sector NE3350 483M 300GB HDD 1x 300 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 485M 450GB HDD 1x 450 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 486M 600GB HDD 1x 600 GB SAS HDD 2 5 inch 12Gb s 15 000 rpm 512B sector NE3350 518M SAS SSD eMLC 200GB SSD CTO 1x 200 GB SAS SSD eMLC 2 5 inch 12Gb s 512B sector Note This is CTO cattegoraized item le...

Page 35: ...ct Name Description Part Number Internal Internal DVD ROM Drive Slim DVD ROM Drive SATA NE3351 123M Internal DVD Super Multi Drive Slim DVD Super Multi drive SATA NOTE Supported OS Windows Server 2012 and 2012R2 NE3351 124M NOTE Not pre installed Needs to order either Internal DVD ROM Drive or Internal DVD Super Multi Drive for server maintenance and or OS installation purpose ...

Page 36: ...0 x1 Low Profile NE3304 151M 1000BASE T Adapter 4 port Broadcom BCM5719 PCIe 2 0 x4 Low Profile NOTE Network cables with RJ 45 plug covers cannot be used NE3304 152M 10GbE 10GBASE Adapter SFP 2ch Qlogic NetXtreme II BCM57810S PCIe 2 0 x8 Low Profile NOTE When connecting to the optical fibre cable NE3304 129 SFP Module 10G SR needs to be ordered per one port max 2 Connection with Twinax cable is av...

Page 37: ...ard 4 ports among multiple cards Up to 4 ports per one team Up to 16 teams per one system NE3304 149 10GBASE SR 2 ports in one card 2 ports among multiple cards Up to 2 ports per one team Up to 8 teams per one system NOTE Teaming with one port shared among multiple teams Not supported Network interface for teaming should be all the same Teaming of the port using iSCSI Not supported Linux Bonding N...

Page 38: ...luster configuration See the table below for supported network interface and OS combinations Network Interface Operating System GbE NE3304 151M 152ML Windows Server 2012 Windows Server 2012 R2 RHEL VMware 10GbE 10GBASE SR NE3304 149 Windows Server 2012 Windows Server 2012 R2 RHEL VMware RHEL Red Hat Enterprise Linux NOTE NIC Teaming Bonding features are not supported on iSCSI interfaces Redundant ...

Page 39: ...TO categorized item lead time for delivery is different from other item Please contact to our sales representative for the delivery schedule Warranty provided earlier until reaching to the end of the specified lifetime for re writhing or until the period defined in the warranty notice Please check regularly the remained lifetime for re writing using the utility of this PCIe SSD FlashMAX III Manage...

Page 40: ...sion Unit 2U N8192 101 N8192 102 N8192 103 N8192 104 SAS Cable 2m for N8192 101 N8192 102 K410 322 02 SAS Cable 2m for N8192 103 N8192 104 K410 333 02 Disk Expansion Unit can be placed just above or just below the server BTO configuration at the server delivery does NOT include RAID configuration Please do RAID configuration by using utility setting By using Flash Backup Unit Write Back is availab...

Page 41: ...n Depending on the FibreChannel FC link speed the available cable type and or length may differ Please refer to the users guide for the Fibre Channel Controller As 2m cables are used to connect SAS Controller and Device Expansion Unit the following remarks should be noted when using Device Expansion Unit Device Expansion Unit 2U N8141 75 Can be mounted with the space less than 3U from the server o...

Page 42: ...3 4 Not available A2020c 1000W 2 3 4 Not available 800W 2 3 4 Not available A2010c 1000W 1 2 3 4 800W 1 2 3 4 A1040c 1000W 1 1 2 2 2 3 2 3 4 4 3 4 Not available 800W 1 2 2 3 4 3 4 3 4 Not available NOTE When selecting Power Supply Unit recommend to consider potential add on of the optional products in the future Redundancy can be selectable no redundancy N 1 and 2N N 1 When one Power Supply Unit f...

Page 43: ...Part Number Trusted Platform Module Kit Module needed to use Windows BitLocker Drive Encryption feature Supported OS Windows Server 2012 Windows Server 2012 NE3315 21 NOTE This is to be shipped only at the delivery of the server cannot be add on later When installed in the server cannot be removed later Need to enable TMP Support in BIOS Set up Menu to use this item Need to save recovery password ...

Page 44: ...oard Optical mouse 1U height 4 pin USB B to 4 pin USB A cable 2 m PS 2 Y splitter cable 2m 15 pin mini D sub VGA cable 2 m BLACK N8143 105F 17inch LCD Console Drawer 1port 17 inch LCD US 103 keys Keyboard with 10 key Touch pad with 3 button 1U height 4 pin USB B to 4 pin USB A cable 1 8 m Two PS 2 cable 1 8 m 15 pin mini D sub VGA cable 1 8 m N8140 108F Keypad Keyboard Unit JP JP 108 keys Keyboard...

Page 45: ...i D sub 1 x 4 pin USB A K410 118 03 Switch Unit Connection Cable Set USB 5m 5 m 1 x 15 pin mini D sub 1 x 15 pin mini D sub 1 x 4 pin USB A K410 118 05 Cascading Switch Unit Connection Cable 1 8 m 1 8 m 1 x 15 pin mini D sub 1x 15 pin mini D Sub 2x PS 2 K410 119 1A NOTE Need Switch Unit Connection Cable for the number of servers up to 8 server There is one VGA connector on the front side of the se...

Page 46: ...20c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 46 8 3 Front Bezel A2040c A2020c A2010c Product Name Description Part Number Front Bezel A2040c A2020c A2010c NE3446 H001 A1040c Product Name Description Part Number Front Bezel A1040c NE3346 H001 ...

Page 47: ...s For calculation considering LAN UTP without shield is φ5mm in diameter at average 1x FC cable corresponds to 1x LAN cable 1x SAS cable corresponds to 2x LAN cables 1x SUV cable corresponds to 4x LAN cables and 1 x USB Cable corresponds to 1 x LAN cable Table for quick reference Model A2040c A2020c A2010c A1040c Cable Arm 70mm Cable Arm 110mm Cable Arm 70mm Cable Arm 110mm Max cable capacity by n...

Page 48: ...CONFIGURATION GUIDE NEC Express5800 A2040c A2020c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 48 ...

Page 49: ...racle Java JRE7 8 32bit version J2SE Runtime Environment for Windows terminal Java7u55 and above for Windows 8 1 Client OS Windows Windows Vista SP2 Windows 7 Windows 8 Windows 8 1 Windows Server 2008 Windows Server 2008 R2 SP1 Windows Server 2012 Windows Server 2012 R2 with IPv6 Windows 7 Windows 8 Windows 8 1 Windows Server 2012 Windows Server 2012 R2 Linux Red Hat Enterprise Linux version 6 Red...

Page 50: ...on the number of the installed CPU and the ordered Memory Riser Card Memory Riser Cards will be installed in the following priority order Need to install at least one Memory Riser Card of CPU Memory Riser Card Slot 1 2 3 4 5 6 7 8 2 1 3 2 4 3 1 4 2 5 3 6 4 1 5 2 6 3 7 4 8 2 COPT Supported Model Standard BTO Configuration Centralized Mode Depending on the number of the installed CPU and the ordered...

Page 51: ...rd Memory Riser Cards will be installed in the following priority order Need to install at least one Memory Riser Card of CPU Memory Riser Card Slot 1 2 3 4 5 6 7 8 2 1 3 2 4 5 7 6 8 1 3 A2010c Up to 4 Memory Riser cards are able to be installed Depending on the number of the ordered Memory Riser Card Memory Riser Card will be installed in the following priority order Need to install at least one ...

Page 52: ...TE Cannot mix RDIMM and LRDIMM in a server Lockstep Mode is a standard setting at the server delivery For DIMM installation priority order 1 to install larger DIMM first and 2 to install DIMMs to the sockets in the priority order shown in the figure below 2 2 Independent Mode Independent Mode provides more performance by having 4 memory channels operate independently This supports Error Detect Cor...

Page 53: ...tep Mode Mirroring between memory pair on CH0 and CH1 AND memory pair on CH2 and CH3 NOTE Cannot mix RDIMM and LRDIMM in a server When using Memory Mirroring the available memory capacity becomes half of physical capacity Lockstep Mode Memory Mirroring is a standard setting at the server delivery To use Independent Mode need to change the mode from BIOS set up menu Cannot use both Memory Mirroring...

Page 54: ...Mode one or 2 memory rank is assigned as a spare out of either a memory pair on CH0 and CH1 OR a memory pair on CH02 and CH03 NOTE Cannot mix RDIMM and LRDIMM in a server When using Memory Rank Sparing the available memory capacity reduces by the capacity of spare memory rank Available Memory Capacity 1 2 of physical memory 8GB RDIMM 1 2 3 4 of physical memory 16GB RDIMM Lockstep Mode Memory Rank ...

Page 55: ...OPT Supported Model Standard BTO Configuration Centralized Mode Memory will be installed to the first younger 2 Memory Riser Cards Follows the same rule afterwards 3 COPT Supported Model With Customized Service Distribution Mode for COPT NE3300 SV101 is ordered Decentralized Mode Memory will be installed equally among each Memory Riser Card 3 2 A2020c Memory will be installed equally to Memory Ris...

Page 56: ...y or mixing HDDs with the same rotation speed is supported in the BTO configuration Mixing HDDs with different rotation speed and mixing HDD and SSD is NOT supported in the BTO configuration Cannot mix the different drives within a RAID group pack When defining hot spare disk under mixed drive configuration need to set Dedicated Hot Spare per RAID group Global Hot Spare is not available Please ref...

Page 57: ...CONFIGURATION GUIDE NEC Express5800 A2040c A2020c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 57 ...

Page 58: ...hed to the RAID Controller for the setting information Connection to RDX USB by Device Expansion Unit Conditions to connect to RDX USB When using Device Expansion Unit 1U 2U with the embedded RDX USB N8151 125 please connect to USB connector on rear side of the server Not allowed to connect to USB connector of SUV cable Please use an external USB cable of USB2 0 supported K410 197 00 K410 307 1 fo...

Page 59: ...ower on off dump Remote power capping BIOS BMC FW update Remote BIOS setup partial configuration only OS shutdown 1 Remote media CD DVD FD USB CLP Command Line Protocol DMTF compliant Remote control via Web browser multi user login at the same time Scheduling without UPS ESMPRO SM required 1 Maintenance EXPRESSSCOPE Profile Key Backup restore BIOS BMC setup information Others Set automatic IP addr...

Page 60: ...rs cannot be used 16 To connect to internal disks Up to 2 Controllers same type can be installed Flash Backup Unit NE3303 H003 can be added 4 RAID Controller 1GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 External RAID Controller 2GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 SAS Controller 6Gb s SAS Card Perf PCI Express 2 0 x8 To connect external device units SAS Controller 12Gb s SAS Card Perf PC...

Page 61: ...ard operates according to the specification of the slot PCI Slot 2 to 9 are hot plug supported 1 For configuring 4 cards please contact to our sales rep for the details Product Code NE3303 178 NE3303 177 NE3303 H004 NE3303 142 NE3303 184 SASController 12Gb s SAS Name Description RAIDController 2GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAIDController 1GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAIDCo...

Page 62: ...isks Up to 2 Controllers same type can be installed Flash Backup Unit NE3303 H003 can be added 4 RAID Controller 1GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 External RAID Controller 2GB RAID 0 1 5 6 Card Perf PCI Express 3 0 x8 SAS Controller 6Gb s SAS Card Perf PCI Express 2 0 x8 To connect external device units SAS Controller 12Gb s SAS Card Perf PCI Express 3 0 x8 Fibre Channel Controller 1po...

Page 63: ...slot specification is lower than the operation performance of the cards the card operates according to the specification of the slot Product Code NE3303 178 NE3303 177 NE3303 H004 NE3303 142 NE3303 184 SASController 12Gb s SAS Name Description RAIDController 2GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAIDController 1GB RAID 0 1 5 6 カード性能 PCI Express 3 0 x8 RAIDController 2GB RAID 0 1 5 6 SASControl...

Page 64: ... or more 7 cores or more 16 16 16 16 16 A2040c A1040c Name Description RAID Controller 2GB RAID 0 1 5 6 Same as Available Slots Matrix general RAID Controller 1GB RAID 0 1 5 6 External RAID Controller 2GB RAID 0 1 5 6 1000BASE T Adapter 2port Same as Available Slots Matrix general Max 8 ports in total per CPU 1000BASE T Adapter 4port 10GBASE Adapter SFP 2ch Fibre Channel Controller 1port 16Gbps Op...

Page 65: ...eral RAID Controller 1GB RAID 0 1 5 6 External RAID Controller 2GB RAID 0 1 5 6 1000BASE T Adapter 2port Same as Available Slots Matrix general Max 8 ports in total per CPU 1000BASE T Adapter 4port 10GBASE Adapter SFP 2ch Fibre Channel Controller 1port 16Gbps Optical Max 2 ports in total per CPU Fibre Channel Controller 2port 16Gbps Optical RAID Controller 2GB RAID 0 1 5 6 Same as Available Slots ...

Page 66: ...port Same as Available Slots Matrix general Max 8 ports in total per CPU Max 4 ports in total per CPU 1000BASE T Adapter 4port 10GBASE Adapter SFP 2ch Fibre Channel Controller 1port 16Gbps Optical Max 2 ports in total per CPU Max 1 port in total per CPU Fibre Channel Controller 2port 16Gbps Optical Fibre Channel Controller 1port 8Gbps Optical Same as Available Slots Matrix general Fibre Channel Co...

Page 67: ...ontroller 2GB RAID 0 1 5 6 SAS Controller 12Gb s SAS 1000BASE T Adapter 2port Same as Available Slots Matrix general Max 8 ports in total per CPU Max 4 ports in total per CPU 1000BASE T Adapter 4port 10GBASE Adapter SFP 2ch Fibre Channel Controller 1port 16Gbps Optical Max 2 ports in total per CPU Max 1 port in total per CPU Fibre Channel Controller 2port 16Gbps Optical Fibre Channel Controller 1p...

Page 68: ...umber of slots depends on the number of CPU Max slot 1CPU 4slots 2CPU 9slots 3CPU 13slots 4CPU 16slots Max of slots 16 1Gb 10Gb combination Max 8 ports for 10Gb and Max 4 ports for 1Gb 1000BASE T Adapter 4port Fibre Channel Controller 1port 16Gbps Optical Max 8 cards in total Max 16 ports in total Fibre Channel Controller 2port 16Gbps Optical Fibre Channel Controller 1port 8Gbps Optical Fibre Chan...

Page 69: ...ble configuration not available SAS Controller 6Gb s SAS SAS Controller 12Gb s SAS not available not available not available not available not available not available not available Max 3 cards in total Max 8 cards in total Max 4 cards in total Max 8 cards in total Max 16 ports in total Fibre Channel Controller 2port 16Gbps Optical Fibre Channel Controller 1port 8Gbps Optical Fibre Channel Controll...

Page 70: ...h 4ch and SAS Controller can be installed In case of having 13 slots available Up to 12 cards for the cards with Priority 1 6 can be installed Up to 11 cards for the cards except 1000BASE T Adapter 2ch 4ch and SAS Controller can be installed Up to 9 cards for 10G BASE Adapter SFP and External RAID Controller can be installed In case of having 16 slots available Up to 15 cards for the cards with Pr...

Page 71: ...han Slot 1 5 8 and 9 7 NE3304 152M 1000BASE T Adapter 4 port Can install to any slot other than Slot 1 8 NE3303 184 SAS Controller 12Gbps Can install to any slot other than Slot 1 NE3303 142 SAS Controller 6Gbps Priority of PCI Slots PCI Slot Number of Available Slots per CPU configuration 4 9 13 16 1 Y Y Y Y 12 N N Y Y 7 N Y Y Y 16 N N N Y 4 Y Y Y Y 10 N N Y Y 2 N Y Y Y 14 N N N Y 3 Y Y Y Y 11 N ...

Page 72: ...e Up to 7 cards for the cards with Priority 1 4 can be installed Up to 7 cards for the cards except 1000BASE T Adapter 2ch 4ch and SAS Controller can be installed In case of having 13 slots available Up to 11 cards for the cards with Priority 1 6 can be installed Up to 11 cards for the cards except 1000BASE T Adapter 2ch 4ch and SAS Controller can be installed In case of having 16 slots available ...

Page 73: ... Channel Controller 8G 1 port Can install to any slot NE3304 151M 1000BASE T Adapter 2 port Can install to any slot other than Slot 1 7 NE3304 152M 1000BASE T Adapter 4 port Can install to any slot other than Slot 1 Priority of PCI Slots PCI Slot Number of Available Slots per CPU configuration 4 9 13 16 1 Y Y Y Y 12 N N Y Y 7 N Y Y Y 16 N N N Y 4 Y Y Y Y 10 N N Y Y 2 N Y Y Y 14 N N N Y 3 Y Y Y Y 1...

Page 74: ...WS2012 WS2012R2 Y Y Y Y 3 ESXi5 5u2 ESXi6 0 N N N N Dynamic CPU Core De allocation RHEL6 6 Y Y Y N 1 WS2012 WS2012R2 N N N N ESXi5 5u2 ESXi6 0 N N N N Dynamic Memory Page De allocation Memory Page Offline RHEL6 6 Y Y Y N 1 WS2012 WS2012R2 Y Y Y Y 3 ESXi5 5u2 ESXi6 0 Y Y Y Y MCA Recovery RHEL6 6 Y Y Y Y WS2012 WS2012R2 Y Y Y Y ESXi5 5u2 ESXi6 0 Y Y Y Y PCIe Hot Add PCIe Hot Remove RHEL6 6 Y Y Y N W...

Page 75: ...very Y Y Y Y PCIe Live Error Recovery RHEL6 6 Y Y Y Y 1 WS2012 WS2012R2 N N N N ESXi5 5u2 ESXi6 0 N N N N Address Based Memory Mirroring RHEL6 6 Y Y Y N 6 WS2012 WS2012R2 N N N N ESXi5 5u2 ESXi6 0 N N N N Enhanced MCA Recovery Gen 2 BIOS MCA Recovery on Gen2 MCA RHEL6 6 Y Y Y Y WS2012 WS2012R2 Y Y Y Y ESXi5 5u2 ESXi6 0 Y Y Y Y Mission Critical I O Failover Windows WS2012 N N N N WS2012R2 Y Y Y Y 2...

Page 76: ...te COPT Static COPT Reboot Required COPT Model RHEL6 6 Y COPT N N N 4 WS2012 WS2012R2 Y COPT N N N 5 ESXi5 5u2 ESXi6 0 Y COPT N N N Dynamic COPT Core Enabling COPT Model RHEL6 6 Y COPT N N N 1 WS2012 WS2012R2 N N N N ESXi5 5u2 ESXi6 0 N N N N Dynamic COPT CORE Sparing COPT Model RHEL6 6 Y COPT N N N 1 WS2012 WS2012R2 N N N N ESXi5 5u2 ESXi6 0 N N N N ...

Page 77: ...ion Critical I O Failover User s Guide 3 Please install spport kit UPDATE module in the EXPRESSBUILDER With Windows Seamless Install the necessary modules are automatically installed 4 As an option if you install the necessary module acccording to the documents Machine Check Monitoring Service User s Guide Capacity Optimization COPT User s Guide for Linux then core allocation among CPUs can be adj...

Page 78: ...tries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds Red Hat is a registered trademark of Red Hat Inc in the U S All other products brands or trade names used in this document are trademarks or registered trademarks of their respective holders NEC shall not be liable for...

Page 79: ...CONFIGURATION GUIDE NEC Express5800 A2040c A2020c A2010c A1040c NEC Corporation Rev 2 0 Sep 2015 79 Revision History Revision Date Description Rev 1 July 2015 Initial Release Rev 2 Aug 2015 Update ...

Reviews: