Express5800/320La System Release Notes
Add the following Warning:
CIRCUIT OVERLOADING:
Consider the current drain of
equipment connected to the supply circuit and the effect of
overloading of circuits might have on overcurrent protection and
supply wiring. Refer to equipment nameplates for power and current
ratings.
Replace the “Temperature Caution” text with the following text:
!
CAUTION
Temperature:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the
rack environment may be greater than the room
ambient temperature. The operating temperature of the
server unit, when installed in an equipment rack, must
not go below 5 °C (41 °F) or rise above 35 °C (95 °F).
Extreme fluctuations in temperature can cause a variety
of problems in your server. It is recommended that the
ambient temperature for a rack-mount unit not exceed
25°C.
!
Chapter 4
Replace the Lithium Battery Warning located in the “Replacing the
Backup Battery” section with the following text:
WARNING
Lithium batteries can be dangerous. There is danger of
explosion if the battery is replaced incorrectly or
replaced with a battery of the wrong type. Replace only
with the same or equivalent type recommended by the
equipment manufacturer. Discard used batteries
according to manufacturer’s instructions or as required
by local ordinance.