6-11 Installing Optional Internal Devices
Updating SDR FW
Refer to the update procedure document of the Motherboard maintenance parts.
Mounting a Heat Sink on the CPU
Refer to the Express Server User’s guide.
Removing the Motherboard
a.
Turn off the power, and then pull the AC cable out.
b.
Remove a side cover.
c.
Extract heat sinks, CPUs, memory boards, PCI boards, etc.
The following procedure explains how to remove a heat sink. (Please DO NOT pull
up straight to draw out a heat sink. If it is removed that way, CPU may be taken out
with heat sink. )
1. When removing retention, use a minus
driver or the tool only for removal of a clip,
hook on a hole and remove.
2. Remove the retention.
3. Please turn the heat sink to the right and
left lightly to remove it. Please DO NOT pull
up straight.
To remove a CPU, follow the procedure for installing a heat sink in reverse order.