![NEC E805-PC2 User Manual Download Page 33](http://html1.mh-extra.com/html/nec/e805-pc2/e805-pc2_user-manual_4197241033.webp)
English-31
English
This LCD monitor can be controlled by connecting a personal computer with a RS-232C terminal.
Functions that can be controlled by a personal computer are:
• Power ON or OFF.
• Switching between input signals.
• Sound Mute ON or OFF.
Connection
LCD M PC
RS-232C Cable
PC
RS-232C
LCD Monitor
NOTE:
If your PC is equipped only with a 25-pin serial port connector, a 25-pin serial port adapter is required. Contact your
dealer for details.
For the pin assignment, please see page 47 “2) RS-232C input”.
To control a monitor, please use the control command. Instructions for the control command can be found on the CD included
with the display. The file is called “External_control.pdf”.
1) Interface
PROTOCOL
RS-232C
BAUD RATE
9600 [bps]
DATA LENGTH
8 [bits]
PARITY BIT
NONE
STOP BIT
1 [bit]
FLOW CONTROL
NONE
This LCD monitor uses RXD, TXD and GND lines for RS-232C control.
The reverse type cable (null modem cable) (not include) should be used for RS-232C control.
Controlling the LCD monitor via RS-232C Remote Control
Summary of Contents for E805-PC2