AP400
– All Types Installation Manual
Page
13
of
34
© NEC Nederland B.V. 2011
DAP Controller - Selective Countries.
This version is used in countries with frequency ranges other than EMEA or North
America.
Note:
In North America, only the “DAP Controller - North America” will be delivered, so
no other frequencies than the North America frequencies and power levels are
possible in North America.
Note:
In Europe, only the
“DAP Controller - International” will be delivered, so no other
frequencies than the European frequencies and power levels are possible in
Europe.
1.3
SITE REQUIREMENTS
Usually the Cabinets will be fixed to existing walls in the positions determined by the Site
Survey.
Do not mount the AP400 to a metal wall!
1.4
TEMPERATURE RANGES
The temperature ranges of the AP400:
Temperature range AP400: -5 to 45 C.
The AP400 should not be exposed to sunlight!
The outside temperature range for the AP400 (all types) mounted in the Outdoor Cabinet
is as follows:
Minimum outside temperature: -20 C
Maximum outside temperature: 45 C
The Outdoor Cabinet should not be exposed to sunlight!
1.5
CABLE SPECIFICATIONS FOR AP400 Types
The cabling to the AP400(E) should be
“Category 5” or “Category 6” Ethernet cabling. The
interface is defined as an SELV interface according EN60950-1. For this reason the
safety restriction as given in the next chapter should be respected:
Summary of Contents for AP400 series
Page 1: ...AP400 All Types Installation Manual Issue December 2011 ...
Page 2: ...AP400 All Types Installation Manual Page 1 of 34 NEC Nederland B V 2011 ...
Page 9: ... NEC Nederland B V 2011 Page 8 of 34 AP400 All Types Installation Manual ...
Page 12: ...AP400 All Types Installation Manual Page 11 of 34 NEC Nederland B V 2011 ...