0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens) 

DATA02 (DISP MODE) 

00H : SPLIT  
01H : BLANKING 

 

11.MULTI MODE Request 
Function 

External control apparatus can know the MULTI MODE information on a plasma monitor. 

Transmission Data 

1FH 80H 60H 3BH 00H CKS 

ACK 

7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS 
DATA00 (SCREEN DIVIDER SETTING) 

01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens

         

 

DATA01 (POSITION OF DIVIDE) 

01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle center selected (9 screens)  
0CH : Middle right selected (9 screens)  
0DH : Bottom left selected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens) 

DATA02 (DISP MODE) 

00H : SPLIT  
01H : BRANKING 

 

12.AUTO ID SET START 
Function 

External control apparatus sets up ID automatically to two or more plasma monitors. 

Transmission Data 

5FH 80H 60H F0H 01H DATA00 CKS 
DATA00   00H~FFH: ID of a master

*1

 is set up. 

 
*: when you use it by the multi-system, please remove the link input of a master

*1

.

 

 

*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.   
 

13.PLE LINK 
Function 

External control apparatus sets up equally PLE between two or more plasma monitors. 

Transmission Data 

DFH 80H 60H F1H 03H DATA00 to DATA02 CKS 
DATA00  00H:PLE LINK ON 

01H:PLE LINK OFF  

DATA01   FFH  
DATA02   FFH 

 

Summary of Contents for 84VP5 -

Page 1: ...5 84VM5 System Weight 319 2 lbs Color Correction NEC CCF Capsulated Color Filter 42VP5 42VM5 Display Weight 61 8 lbs Quad Mount Wt 72 lbs Notes This document is intended to be used as a reference guide to supply useful information for a design or installation It is not intended to be a step by step procedure for installation Any ceilings or walls must be strong enough to support the display system...

Page 2: ...stallation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 2 of 14 System Dimensions Dimensions are in inches For millimeters multiply by 25 4 8 0 48 0 80 2 ...

Page 3: ...o a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 3 of 14 System Ventilation Requirements Dimensions below show minimum requirements for ventilation Wall Minimum Wall Recess Opening 84 2 x 52 0 Ventilation Requirement is 2 around the units Wall 2 0 52 0 84 2 2 0 2 0 2 0 ...

Page 4: ... Visual Systems 84VP5 84VM5 Installation Guide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 4 of 14 Quad Mount Isometric Drawing ...

Page 5: ...four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 5 of 14 Mounting Points for Quad Mount Dimensions are in inches For millimeters multiply by 25 4 16 0 24 0 16 0 32 1 24 1 24 0 5 9 5 9 18 1 4 5 ...

Page 6: ...end 8 CTS Clear to send 9 No Connection 2 Connector on the external equipment side Serial port RS 232C connector See the specifications of the equipment that is to be connected for the type of connector and the pin assignment 3 Wiring Use a crossed reverse cable Wire the cable so that each pair of data lines cross between the two devices These data line pairs are RXD Receive data and TXD Transmit ...

Page 7: ... and unit ID 2 are numbers used to identify the equipment that is to be connected 60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer Unit ID 1 Indicates the equipment sending the signal When supporting Set ID by the command 1 4 bits of low ranks of Set ID are set up Unit ID 2 Indicates the equipment receiving the signal When supporting Set...

Page 8: ... 60 4E 00 CD In ID 5 the value of ID 1 4 is set up 9D 84 60 4E 00 CF The example of a change in the single mode of a 4th page multi system configuration and the multi mode is shown below ID of the set used as a master etc PC is set to 50 and it assumes that ID is shaken by AUTO ID to each set ID shaken at each set is as follows Upper left set master ID 50 32h Upper right set ID 51 33h Lower right ...

Page 9: ...hed off 3FH 60H 80H 4FH 00H CKS 03 Input Switch Change Function The external control equipment switches the input of the plasma monitor Transmission Data DFH 80H 60H 47H 01H DATA00 CKS DATA00 Input Select 01H Video1 02H Video2 03H Video3 05H HD HD1 or DTV or DTV1 06H HD2 DTV2 or SCART1 SCART2 07H RGB1 PC1 08H RGB2 PC2 0CH RGB3 PC3 0DH HD3 SCART3 ACK The plasma monitor returns the following ACK whe...

Page 10: ... CKS DATA00 01H NORMAL 02H THEATER1 03H THEATER2 04H Default 07 SCREEN MODE Select Function The external control equipment switches the screen mode of the plasma monitor Transmission Data DFH 80H 60H 51H 01H DATA00 CKS DATA00 02H STADIUM 03H ZOOM 04H NORMAL 05H FULL 06H REAL 08H UNDERSCAN 09H 14 9 ACK 7FH 60H 80H 51H 01H DATA00 CKS DATA00 02H STADIUM 03H ZOOM 04H NORMAL 05H FULL 06H REAL 08H UNDER...

Page 11: ...t selected 4 screens 02H Upper right selected 4 screens 03H Lower right selected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top right selected 9 screens 0AH Middle left selected 9 screens 0BH Middle center selected 9 screens 0CH Middle right selected 9 screens 0DH Bottom left selected 9 screens 0EH Bottom middle selected 9 scre...

Page 12: ...lected 4 screens 04H Lower left selected 4 screens 07H Top left selected 9 screens 08H Top middle selected 9 screens 09H Top right selected 9 screens 0AH Middle left selected 9 screens 0BH Middle center selected 9 screens 0CH Middle right selected 9 screens 0DH Bottom left selected 9 screens 0EH Bottom middle selected 9 screens 0FH Bottom right selected 9 screens DATA02 DISP MODE 00H SPLIT 01H BRA...

Page 13: ...H 1 Master means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution 14 VIDEO WALL SETTING Function External control apparatus sets 4screens or 9screens as a video wall Transmission Data DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS DATA00 01H 1 screen Matrix display function does not work 04H 4 screens 2 2 video wall 09H 9 screens 3 3 video wall DATA 01 00H FFH Mast...

Page 14: ...uide using four 42VM5 or 42VP5 Plasma Displays also a reference for optional Quad Mount used with 42VM5 or 42VP5 v1 3 www necvisualsystems com Page 14 of 14 Bit2 Power Status 0 POWER ON 1 POWER OFF STANBY Bit3 0 Fixed Bit4 0 Fixed Bit5 0 Fixed Bit6 0 Fixed Bit7 0 Fixed ...

Reviews: