12C

Reset Time

, press ENTER button to confirm. Press MENU button back to the last 

menu or exit menu mode let the unit idle one minute.   

Firmware Version 

Select 

Firmware Version

, press ENTER button to confirm, firmware version will show 

on the display, press MENU button back to exit. 

 

Reset Functions 

Enter MENU mode, select 

Reset Function

, press ENTER button to confirm, use UP 

and DOWN button to select

 Pan/Tilt, Zoom 

or

 All. 

Pan/Tilt

 

Reset Pan/Tilt

 

Select 

Pan/Tilt

, press ENTER button to confirm, use UP and DOWN button to select 

Yes

 (the unit will run built-in program to reset pan and tilt to their home positions)

 

or

 No

press ENTER button to store. Press MENU button back to the last menu or let the unit 

idle one minute to exit menu mode. 

Zoom

 

Reset Zoom

 

Select 

Zoom

, press ENTER button to confirm, use UP and DOWN button to select 

Yes

 

(the unit will run built-in program to reset

 Zoom

 to their home positions)

 

or

 No

, press 

ENTER button to store. Press MENU button to exit.   

All

 

Reset All

 

Select

 All,

 press ENTER button to confirm, use UP and DOWN button to select 

Yes

 

(the unit will run built-in program to reset all motors to their home positions)

 

or

 No

press ENTER button to store. Press MENU button to exit. 

Special Functions 

Enter MENU mode, select 

Special Functions

, press ENTER button to confirm, use UP 

and DOWN button to select

 Fixture Maintenance 

or

 Factory Setting. 

Summary of Contents for NBL-Z1912

Page 1: ...CM 300ZS User Manual Professional Entertainment Technology QQQQQQQQ 19 15W 4 in 1 QF 1026 LEDZOOMMOVINGHEADQF 1026 LED ZOOM MOVING HEAD LED ZOOM MOVING HEAD 19 x12W 4 in 1...

Page 2: ...cations 3 3 How To Set The Unit 4 3 1 Control panel 4 3 2 Main Function 5 3 3 Home Position Adjust 13 4 Control By Universal DMX Controller 14 4 1 DMX 512 Connection 14 4 2 Address Setting 15 4 3 DMX...

Page 3: ...erials close to the unit while operating as it is fire hazard y Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base y Maximum ambient tem...

Page 4: ...taching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture...

Page 5: ...ntrol panel Display To show the various menus and the selected functions LED POWER ON Power On NULL No function NULL No function DMX ON DMX input present Button MENU To select the programming function...

Page 6: ...ain Function To select any of the given functions press the MENU button up to when the required one is showing on the display Select the function by ENTER button and the display will blink Use DOWN an...

Page 7: ...6C...

Page 8: ...tton to view other DMX value Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Setting Enter MENU mode select Fixture Setting press ENTER button to conf...

Page 9: ...ect No normal while pan tilt moving or Yes blackout while pan tilt moving press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode White Ba...

Page 10: ...Law Light intensity control is coarser at low levels and finger at high levels S cure Light intensity control is finger at low levels and high levels and coarser at medium levels Display Setting Enter...

Page 11: ...minute to exit menu mode Temperature Unit Select Temperature Unit press ENTER button to confirm present mode will blink on the display use UP and DOWN button to select or press ENTER button to store...

Page 12: ...button to confirm then use UP and DOWN button to adjust the value press ENTER button to store the fixture will run as the channel value indicates Press MENU button back to the last menu or exit menu m...

Page 13: ...tilt to their home positions or No press ENTER button to store Press MENU button back to the last menu or let the unit idle one minute to exit menu mode Zoom Reset Zoom Select Zoom press ENTER button...

Page 14: ...it Factory Setting Select Factory Setting press ENTER button to confirm the fixture will reset to factory settings and exit menu mode 3 3 Home Position Adjust In the main functions hold Enter button f...

Page 15: ...ther in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged c...

Page 16: ...that the units can receive DMX signal Press MENU button to enter menu mode select DMX Functions press ENTER button to confirm use UP and DOWN button to select DMX Address press ENTER button to confirm...

Page 17: ...16C 4 3 DMX 512 Configuration 14 channel mode...

Page 18: ...17C...

Page 19: ...e another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working...

Page 20: ...Innovation Quality Performance...

Reviews: