1.  SAFETY INSTRUCTION 

Nebula ALKAID PROFILE 50.0 is designed and manufactured to meet the requirements 

of  People’s  Republic  of  China  and  international  safety  regulations.  Modifications  to  the 

product  could  affect  safety  and  render  the  product  non-compliant  to  relevant  safety 

standards. 

Instructions pertaining to continued protection against fire, electric shock, and injury to 

persons are found throughout this manual. Please read all instructions prior to assembling, 

mounting, and operating this equipment. 

 

IMPORTANT 

 

ALWAYS READ THE USER MANUAL BEFORE OPERATION. PLEASE CONFIRM THAT 

THE  POWER  SUPPLY  STATED  ON  THE  PRODUCT  IS  THE  SAME  AS  THE  MAINS 

POWER SUPPLY IN YOUR AREA. 

 

● 

This product must be installed by a qualified professional. 

● 

Always operate the equipment as described in the user manual. 

● 

A minimum distance of 1m must be maintained between the equipment and combustible 

surface. 

● 

The product must always be placed in a well ventilated area. 

● 

Always make sure that the equipment is installed securely. 

● 

DO NOT stand close to the equipment and stare directly into the LED light source. 

● 

Always disconnect the power supply before attempting and maintenance. 

● 

Always make sure that the supporting structure is solid and can support the combined 

weight of the products. 

 

 

ATTENTION 

 

 

This product left the place of manufacturer in perfect condition. In order to maintain this 

condition and for safe operation, the user must always follow the instructions and safety 

warnings described in this user manual. 

● 

Avoid shaking or strong impacts to any part of the equipment. 

● 

Make sure that all parts of the equipment are kept clean and free of dust. 

● 

Always make sure that the power connections are connected correct and  secure. 

● 

If there is any malfunction of the equipment, contact us immediately. 

● 

When transferring the product, it is advisable to use the original packaging in which the 

product left the factory. 

● 

Shields, lenses or ultraviolet screens shall be changed if they have become damaged to 

such an extent that their effectiveness is not conformable. 

Summary of Contents for ALKAID PROFILE 50.0

Page 1: ...FORE OPERATING THE LIGHT FIXTURE USER MANUAL ALKAID PROFILE 50 0 LED SPOT FRAMING MOVING HEAD WITH CMY CTO and IRIS Version 1 2 OVER THIS MANUAL BEFORE OPERATING THE LIGHT FIXTURE USER MANUAL SPOT FRAMING MOVING HEAD OVER THIS MANUAL BEFORE OPERATING THE LIGHT FIXTURE ...

Page 2: ...ed in a well ventilated area Always make sure that the equipment is installed securely DO NOT stand close to the equipment and stare directly into the LED light source Always disconnect the power supply before attempting and maintenance Always make sure that the supporting structure is solid and can support the combined weight of the products ATTENTION This product left the place of manufacturer i...

Page 3: ...ION Lens Head Arm Botton LCD Display Up button Menu button Down button Left button Enter button Right button DMX IN 3 pin DMX OUT 3 pin DMX IN 5 pin DMX OUT 5 pin POWER IN POWER OUT NETWORK IN NETWORK OUT TURN ON OFF FUSE 8A ...

Page 4: ...RAMING SHUTTER Shutters 4 independent framing shutters System Rotation 90 COLOR 6 Dichoric Colors plus open Index Bi directional rotating rainbow effect CMY CTO Colormix system FIXED GOBOS 1 fixed gobo wheels with 8 metal gobos plus open Shake Bi directional flow effect ROTATING GOBOS 1 rotation gobo wheels with 6 interchangeable glass gobos plus open Interchangeable rotating Shake Bi directional ...

Page 5: ... MOUNTING AND INSTALLATION The fixture can be mounted in any position Always ensure that mounting surface can withstand 10 times the weight of the fixture Always use a safety cable when mounting the fixture in any elevated position Upright ...

Page 6: ...bed in the following sections Up Scroll Up through the menu list or increase the value of the current function Menu Scroll through the main menu or exit from the current sub menu Down Scroll Down through the menu list or decrease the value of the current function Left Scroll Left through the mian menu or sub menu Enter Enter the currently selected menu or confirm the current function value Right S...

Page 7: ... 6 ...

Page 8: ... 7 ...

Page 9: ... 8 8 DMX CHANNEL ASSIGNMENTS This product has 36 52 DMX channels as below 36 Channels mode ...

Page 10: ... 9 ...

Page 11: ... 10 ...

Page 12: ... 11 52 Channels mode ...

Page 13: ... 12 ...

Page 14: ... 13 ...

Page 15: ... dust Clean the fan each week A detailed electric check by approved electrical engineer each three month make sure that the circuit contacts are in good condition prevent the poor contact of circuit from overheating We recommend a frequent cleaning of the device Please use a moist lint free cloth Never use alcohol or solvents There are no serviceable parts inside the device Should you need any spa...