WALL - Technical Handbook
IN1 and IN2
When IN1 and/or IN2 are trigged the logic can take a look at either jumper J2 (which
determines if both inputs should be normally open or normally closed, previously
described in "3.4 J1 and J2, jumpers") or use the value selected.
Values available:
• Normally open
• Normally closed
• Use jumper J2 (default)
Port 1 and 2 input types settings are only available on certain WIOR devices.
5.9.2 Conditions
Certain conditions can be applied when the the selected button/input is trigged and
both conditions must be fulfilled to apply the assigned action.
5.9.3 Action
If the condition is met an appropriate action can be assigned. The list of actions is
editable on tab
Actions
, see "5.11 Actions tab".
5.10 Radio events tab
Available only for WIOR devices.
Picture 38.
Radio events tab.
Up to eight radio events can be monitored from the unit and each radio event is
programmable to perform certain actions if criterias and conditions are met. As an
idea of how this works it can be viewed as a chain of questions:
1. What radio event is received?
2. Does the
Radio ID
code match?
3. Does the
Alarm type
match?
4. Does the
User type
match?
5. Does the assigned conditions apply?
6. What action should be applied?