3.2 OUT1 and OUT2, relay outputs
There are two outputs which will be opened and closed according to action plan or
remote activation message. The outputs are galvanic separated from the wired inputs
and each other. Each output can be configured to be normally open or normally
closed.
After power on, both outputs are opened or closed according to configuration. After
power off, both outputs keep their last status.
The outputs can also be controlled by a D-SERVER using group activation codes.
This means if the function is enabled in the unit and a D-SERVER sends out the
appropriate group activation code, the affected units will activate the output relay
according to the action specified in the radio message.
The outputs are not allowed to control voltages or currents exceeding values
specified in the technical data, see "Appendix A Technical data".
3.3 IN1 and IN2, wired inputs
In the screw connector there are two wired inputs, IN1 (pin 6) and IN2 (pin 5). Both
inputs have a common ground (pin 7) and must be connected to potential free
contacts. They can both be configured as normally open or normally closed by using
jumper J2. They can also be configured by radio configuration.
For a technical specification of cable lengths and cable characteristics,
see "Appendix A Technical data".
Please note that input changes are ignored for 10 seconds after power on.
3.4 J1 and J2, jumpers
There are two jumpers for configuring the unit, see below.
Jumper# On (mounted)
Off (not mounted)
J1
Radio receiver on, 24V mode
Radio receiver off, battery mode
J2
Inputs (IN1 and IN2) normally closed
Inputs (IN 1 and IN2) normally open
Table 5.
Jumper settings.
Jumper J2 can be overrided by settings in WALL Family Programmer, see "5.9.1 Input
3.5 6.35 mm telejack
Valid only for PEAR and PUSH+PEAR.
Summary of Contents for WALL Famiy
Page 1: ...WALL Family neat Technical Handbook NE41 11014 02 v4 1 ...
Page 54: ...neat 54 NE41 11014 02 v4 1 WALL Technical Handbook This page intentionally left blank ...
Page 55: ...neat 55 NE41 11014 02 v4 1 WALL Technical Handbook This page intentionally left blank ...
Page 56: ...www neat group com ...