D-POS II - NE41 17028-00 v1.0
5
Engli
sh
3
Installation
D-POS II is designed to be installed either on a wall (with the
supplied 13 mm mounting socket) or in a junction box with cc 60 mm
using an optional 1 mm mounting socket.
Connect the power input to screw terminals #1 & #2.
Only use AC/DC adaptor provided by NEAT, see Table 7 on page
or use
12-24 V
DC
as central power supply. The central power supply must be limited
to supply maximum 36 VA.
To adjust the rotary switches and potentiometers we recommend a flat
screwdriver with a 2.4 x 0.5 mm blade. Use max. 10 meters of cable with
cable area 0.4 mm
2
or more (AWG 21) for ferrite and loop antennas.
D-POS II and its corresponding parts must be installed by a professional fitter.
3.1
Configuration with DIP switches DIP 1 - DIP 8
The DIP switches DIP1 - DIP8 configures some parameters in the
D-POS II. The table below displays the functions for a particular DIP
switch.
Picture 1. PCB DIP Switches
Text
Function
On
Off
DIP1
Configuration
Computer
DIP switches
DIP2
Not used
N/A
N/A
DIP3
External input mode
Normally closed
Normally open
DIP4
External input function
Antenna
Radio alarm
DIP5
Relay output source
Tamper/Antenna error
Radio received
DIP6
Send radio alarm at tamper Yes
No
DIP7
Power level, see 3.8
High
Low
DIP8
Walk test mode on/off
Active
Not active
Table 2. DIP Switches (S4) functions
Max cable length LOOP: 10 meters with cable area >0.4 mm
2
(AWG 21).
Summary of Contents for D-POS II