PROBLEM--SPIN DRIVE NOT WORKING IN SPIN MODE.
Assuming (SSS) System Start Switch is on with 120 volts AC to control panel and all other functions are working.
Verify all wires shown on the wiring diagram are correct and pull on wire terminals with approximately 3 lbs force to
verify there are no loose terminal connections and/or no loose crimps between the wire and the terminal. If problem
persists, test as listed below.
Possible Cause
Spin Speed Pot (SSP)
set to zero
Spin Motor Switch
(SMS) is not on
Circuit Breaker is
Tripped (4 AMP)
Spin Drive Control
(SDC) is not working
Spin Drive motor is
bad
Spin drive control in
Torque mode
Checkout Procedure
A.
Set (SSP) to 200 on the
control panel.
B.
Turn (SMS) switch on
C.
Reset Circuit Breaker on right
side of machine above the Con
-
trol Panel. Push in if tripped.
D.
Check (SDS) L1 to L2 for 120
Volts AC
E.
With the Selector switch in
spin and the spin pot set to
400RPM Check (SDC) A1 and A2
for 90-120 Volts DC
F.
Check spin motor
continuity
G.
Check continuity of mode
selector switch.
Spin Motor works
Yes--end troubleshooting
No--go to Step
B
next
Spin Motor works
Yes--end troubleshooting
No--go to Step
C.
next
Spin Motor works
Yes--end troubleshooting
No--go to Step
D.
next
(SDC)Remove wires to Terminals L1 and L2 and
test between wires for 120 VAC.
Yes--reconnect wires to board, then go to Step
E.
next
No--Verify Power to Circuit Breaker and SMS
and continuity of wires. Replace CB or SMS if
needed.
(SDC) Remove wires, test Terminals A1 to A2 on
the board for approx 90-120 V DC
Yes--reconnect wires and go to Step
F.
next
No--go to Step
G.
Remove wires at Terminal Strip 1, Term 4 & 5
check 0 ohms across the black and white wires
from the motor. Reading 0 Ohms
Yes--end troubleshooting, spin drive should run,
if not, replace motor.
No--go to Step
J.
Light on SDC next to SP should be ON. If not,
remove wires 41SDCMOD and 44SDCCOM from
SDC control board. Check continuity of wires,
should read 0 ohms.
Light next to SP is ON?
No--Check continuity of STS switch, replace if
bad. (Machine was in Torque mode)
Yes-- Light next to SP is ON but machine does
not work. Reinstall wires, Go to
Step
H
. next.
DISCONNECT POWER FROM
MACHINE !
ELECTRICAL TROUBLESHOOTING
Summary of Contents for 555 SRI
Page 42: ...42 ORIGINAL INSTRUCTIONS 55761 EXPLODED VIEW DOOR ASSEMBLY ...
Page 44: ...44 ORIGINAL INSTRUCTIONS 6329575 EXPLODED VIEW REAR GUARD DOOR ASSY ...
Page 46: ...46 ORIGINAL INSTRUCTIONS 6329575 EXPLODED VIEW REAR GUARD DOOR ASSY ...
Page 48: ...48 ORIGINAL INSTRUCTIONS 55583 EXPLODED VIEW GRINDING HEAD ASSEMBLY ...
Page 50: ...50 55451 EXPLODED VIEW PIVOT ARM GRINDING SHAFT ASSY 1 of 2 ...
Page 52: ...52 55451 EXPLODED VIEW PIVOT ARM GRINDING SHAFT ASSY 2 of 2 ...
Page 54: ...54 ORIGINAL INSTRUCTIONS 55563 EXPLODED VIEW TRAVERSE DRIVE ASSEMBLY ...
Page 56: ...56 ORIGINAL INSTRUCTIONS 55452 EXPLODED VIEW MOWER SUPPORT ASSEMBLY ...
Page 58: ...58 ORIGINAL INSTRUCTIONS EXPLODED VIEW VERTICAL MOWER SUPPORT ASSEMBLY ...
Page 60: ...60 ORIGINAL INSTRUCTIONS 55708 EXPLODED VIEW CARTON ASSEMBLY ...
Page 62: ...62 ORIGINAL INSTRUCTIONS EXPLODED VIEW ALIGNMENT GAGE ASSEMBLY ...
Page 66: ...66 ORIGINAL INSTRUCTIONS 55628 EXPLODED VIEW SPIN DRIVE ASSEMBLY 2 5 1 3 6 4 7 9 ...
Page 68: ...68 ORIGINAL INSTRUCTIONS EXPLODED VIEW CONTROLS ASSEMBLY ...
Page 70: ...70 ORIGINAL INSTRUCTIONS EXPLODED VIEW ELECTRIC PANEL SUB ASSEMBLY ...
Page 72: ...72 ORIGINAL INSTRUCTIONS 55041 WIRING DIAGRAM ...