18 | Power Modules

Power Modules

Begin each session with two fully charged power modules to ensure uninterrupted operation. Promptly transfer
discharged power modules to the charging station for replacement with a fully charged unit.

Warning: 

Fully  charge  each  new  power  module  before  first  use.  This  is  required  to  ensure  accurate

charge level reporting.

Preparing a Power Module for First Use

The power module must be prepared before being placed on a ZeroWire stand. 

1. Place the power module on a 4-dock ZeroWire Mobile Charging Station until the blue LED light turns on and

all LED bars are indicating fully charged.

2. Remove the First Use Instructions label after charging the power module. 

Power Module Overview

The power module display has a power switch, overload
indicator, service indicator, and charge level LEDs.

Power Module Power On

Note: 

Although a ZeroWire Mobile can operate with one

power module, to obtain optimum performance two
modules should always be installed.

Note: 

For best performance

always install a fully charged

power module

To  power  on  a  ZeroWire  Mobile  with  two  power  modules
installed, press the power switch on one power module for
approximately 3 seconds. The power switch will illuminate
with a single beep and the charge level LEDs will illuminate
successively from the bottom up and then all blink off and
on in unison, followed by three beeps signaling that the
power module authentication code has been confirmed for
use. The power switch and charge level LEDs of the active
power module are illuminated. The reserve power module
displays only illuminated charge level LEDs.

Power Module Power Off

Press the power switch on the active power module for approximately 3 seconds. The power switch LED will go
dark with two beeps, followed by the charge level LEDs turning off sequentially from the top down.

Low Charge Level Audible Notification

A beep is repeated at 2-minute intervals starting 30 minutes prior to full discharge of a secondary power module
if the depleted primary power module has not been replaced with a charged unit.

Note:

 The Low Charge Level Notification is functionally critical and cannot be disabled.

Power

Switch

Overload

Indicator

Service

Indicator

Charge

Level

LEDs

Summary of Contents for 90Z0164

Page 1: ...ZeroWire Mobile USER MANUAL U S ONLY ENGLISH ...

Page 2: ......

Page 3: ...e without notice NDS provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDS All trademarks are the property of the...

Page 4: ......

Page 5: ...ire Mobile Components 13 Optional Components 13 ZeroWire Mobile Monitor Installation 14 Mounting a Monitor to the ZeroWire Mobile 14 Connecting a Monitor to the ZeroWire Mobile 14 ZeroWire Mobile Monitor Setup 15 Height Adjustment of Monitor 15 Tilt Adjustment of Monitor 15 ZeroWire Mobile Transport 16 Procedure for Moving the ZeroWire Mobile 16 Charging Station 17 Charging Station Overview 17 Pow...

Page 6: ......

Page 7: ...pliance with the Waste Electrical and Electronic Equipment Directive WEEE Directive This symbol indicates the device is a Medical Device This product is intended only for use by healthcare professionals in professional healthcare environments Safety Compliance This product is T U V approved with respect to electric shock fire and mechanical hazards only in accordance with CAN CSA C22 2 No 60601 1 ...

Page 8: ...titioner Read instructions for use before using or installing the product Conformité Européenne Care should be taken when using the product Waste Electrical and ElectronicEquipment Directive EU Recyclable Taiwan Conforms to the transportation standards for Class 9 hazardous materials Federal Communications Commission Conformance US Underwriters Laboratory UL listed component Meets the requirements...

Page 9: ...vals starting 30 minutes prior to full discharge of a secondary power module if the depleted primary power module has not been replaced with a charged unit Note The Low Charge Level Notification is functionally critical and cannot be disabled Warning The ZeroWire Mobile should not be used with medical equipment that poses a safety risk to patients if battery power is lost or the audible notificati...

Page 10: ...ot intended for use in the sterile field Contraindications The ZeroWire Mobile is not intended for use with life supporting equipment and under no circumstance must it be used in this way Any use or integration with a medical device is strictly and exclusively the responsibility of the Medical Device manufacturer agent reseller or integrator selling this product They are responsible for appropriat...

Page 11: ...ce kit part number 90Z0176 Please reference ZeroWire Mobile Components on page 13 for additional information regarding ZeroWire Mobile system components and accessories Safety Features See Charging Station Overview on page 17 and Power Module Overview on page 18 Authentication All ZeroWire Mobile power modules are factory programmed with a password code used for verification that the power module ...

Page 12: ...irst use after storage or transportation power modules must be charged to full capacity to set an internal benchmark used to calculate percentages of capacity for accurate display of charge levels during use Active Use Charge Requirement At least once every 30 days power modules in active use must be fully charged from a discharged state to maintain accurate display of charge levels and to maximiz...

Page 13: ...erve these conditions will invalidate the warranty and reduce the life expectancy of power modules Storage Storage temperature range for the ZeroWire Mobile should not exceed 14 113 F 10 45 C Storage relative humidity range for the ZeroWire Mobile should not exceed 30 80 non condensing Failure to observe these conditions will invalidate the warranty and reduce the life expectancy of power modules ...

Page 14: ...8 General Specifications ...

Page 15: ...to the Inner Extrusion Subassembly by screwing the threaded end of the Release Lever into the Release Lever Subassembly 8 and securely hand tighten 1 Hinged Mounting Plate 2 Top Plate 3 Inner Extrusion Subassembly 4 Outer Extrusion Subassembly 5 M6x16mm Cap Head Screw 2x 6 M6 Flat Washer 2x 7 Release Lever 8 Release Lever Subassembly 9 Channel Adapter 10 Handle Subassembly 11 M6x12mm Flat Hd SOC S...

Page 16: ...ea ndssi com Part Number Description 90Z0164 ZeroWire Mobile Service Kit Castor 90Z0292 ZeroWire Mobile Service Kit Castor Electric Conductive 90Z0165 ZeroWire Mobile Service Kit Handle Assembly 90Z0166 ZeroWire Mobile Service Kit Covers 90Z0168 ZeroWire Mobile Neutrik Power Cable 90Z0169 ZeroWire Mobile Switchcraft Power Cable 90Z0170 ZeroWire Mobile Service Kit Connector Cap 90Z0171 ZeroWire Mob...

Page 17: ...Wall Mount Bracket has been securely installed to the wall location position the Bracket Tab Slots on the back of the Charging Station over the Bracket Tabs of the Wall Mount Bracket and carefully lower the Charging Station until both Slots are securely mounted on the Tabs 4 Connect the Charging Station to AC mains using the provided hospital grade AC mains Power Cable P N 35D0022 B Illuminated LE...

Page 18: ...r module Note It is recommended that power modules be regularly inspected for enclosure damage If a unit is damaged it should be immediately removed from use Cleaning The ZeroWire Mobile system should be kept clean and free of dust The Dock charger and Power Module should be cleaned using a damp cloth with water or alcohol solution Please observe the follow precautions Power modules are protected ...

Page 19: ...mponents External Charger P N 30H0006 for use with the ZeroWire Mobile Power Cable P N 90Z0168 for use with NDS 26 HB 32 monitors Neutrik connector Power Cable P N 90Z0169 for use with NDS 19 26 monitors SwitchCraft connector ZeroWire Mobile wall power module charger 4 bay P N 30H0001 with one each United States and European power cord ZeroWire Mobile power module P N 30H0006 ...

Page 20: ...crew holes Attach the monitor using the provided M4 thumb screws Lightly tighten each screw until all 4 screws have been installed and then tighten each screw securely Connecting a Monitor to the ZeroWire Mobile 1 Remove the monitor cable cover 2 Connect the monitor DC power cable first to the ZeroWire Mobile DC output connector and then to the monitor DC input connector with the power cable passi...

Page 21: ...ed vertically from the axis of the mounting plate hinge To raise and lower the monitor assembly confirm that the caster brake locks are applied to stabilize the ZeroWire Mobile then lift the release lever and press up or down on the upper handle Caution Extend fingers when lowering the monitor assembly to prevent accidental pinching 68 2 173 cm 53 94 137cm 50 5 To adjust the monitor angle first co...

Page 22: ... top plate assembly and monitor until the top plate is positioned approximately 4 10 cm above the top of the base column Release Caster Brake Locks 3 Confirm that all caster brake locks are unlocked in the upper position and that all casters roll freely 4 Confirm that the path of transport is free of cables and any other obstructions Move the ZeroWire Mobile 5 Firmly grasp the upper and lower hand...

Page 23: ...charge levels of each power module are monitored and charging is resumed if self discharging drops a charge level below 95 It is recommended that only fully charged power modules be installed for use on the ZeroWire Mobile Charging Station Specifications INPUT Minimum Maximum Units InputVoltage 100 240 Vac Input Frequency 50 60 Hz Input Current 240Vac 50Hz 2 3 A rms 100Vac 60Hz 4 6 A rms Charge Cu...

Page 24: ...install a fully charged power module To power on a ZeroWire Mobile with two power modules installed press the power switch on one power module for approximately 3 seconds The power switch will illuminate with a single beep and the charge level LEDs will illuminate successively from the bottom up and then all blink off and on in unison followed by three beeps signaling that the power module authent...

Page 25: ...minate the charge level LEDs Power Module Charging A single Power Module will take approximately 2 5 hours to become 90 charged from a fully discharged state While charging the current charge level is indicated with illuminated charge level LEDs A single LED cycles from bottom to top to indicate the ongoing progression of the charging process The top LED blinks on and off while charging from 90 10...

Page 26: ...ntact NDS Customer Service Discharge Cut Off A power module is in the discharge cut off state when the power module display does not turn on when the power button is pressed If a power module enters the discharge cut off state it must be immediately placed on an 4 dock ZeroWire Mobile Charging Station for a minimum of three days to recharge to full capacity Warning Allowing a power module to enter...

Page 27: ... charging and a power module with available capacity remains installed the system will switch to the remaining power module with uninterrupted discharge Power modules can safely be installed into or removed from stand docks at any time without powering off the unit Warning To prevent a system shutdown when replacing a discharged power module ensure that you are removing the discharged unit and not...

Page 28: ...charge at a slow rate When the external charger is connected without Power Modules installed The display will be powered by the external charger Power Modules can be installed and removed while the external charger is connected without affecting power to the display The external charger port covered is the NDS badge as indicated in the figure below Using nonmetallic flat head screwdriver carefully...

Page 29: ...External Charger 23 The external charger External charger power cord Note The plug may vary depending on region ...

Page 30: ...24 External Charger ...

Page 31: ...netic Environment Guidance RF emissions CISPR 11 Group 1 The product uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The product is suitable for use in all establishments including domestic establishments and those directly connected to the public low volt...

Page 32: ...ures may be necessary such as re orienting or relocating the product Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Immunity Test Test Level Professional Healthcare Electrostatic discharge ESD IEC 61000 4 2 2 4 6 8kV contract discharge 2 4 6 8 15 kV air discharge Radiated RF field IEC 61000 4 3 3 V m 80MHz to 2700MHz 80 AM 1 kHz Proximity fields from wireless ...

Page 33: ...eparation Distance Notes Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people WARNING Portable RF communications equipment including peripherals such as antenna cables and external antennas should be u...

Page 34: ...28 Electromagnetic Compatibility Tables ...

Page 35: ...y turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult your dealer or an experienced radio TV technician f...

Page 36: ...IONS AND OR GUARANTEES OF ANY TYPE NATURE OR EXTENT BE IT IMPLIED EXPRESS AND OR WHETHER ARISING UNDER OR AS A RESULT OF ANY STATUTE LAW COMMERCIAL USAGE CUSTOM TRADE OR OTHERWISE ARE HEREBY EXPRESSLY EXCLUDED AND DISCLAIMED NDS its suppliers and or distributors are not liable directly or by way of indemnity for any special incidental consequential punitive exemplary or indirect damages including ...

Page 37: ......

Page 38: ...ing Germany 49 89 31 707 100 info novanta europe novanta com Asia Pacific Novanta Japan East Square Omori 6 20 14 Minamioi Shinagawa ku Tokyo 140 0013 Japan 81 3 5753 2466 info ndssi com Oriental Media Center Suite 2302 Tower C No 4 Guang Hua Road Chao Yang District Beijing 100026 China 86 10 8559 7859 info ndssi com NDS Quality System ISO 13485 FDA Registration 2954921 ...

Reviews: