background image

iv 

Tall

 

Pole

 

Mount ................................................................................................. 25

 

Base

 

Plate

 

Mounting

 

Hole

 

Dimensions ......................................................... 26

 

Cash

 

Drawers........................................................................................................... 27

 

NCR

 

2181

 

Cash

 

Drawer ................................................................................... 27

 

NCR

 

2186

 

Compact

 

Cash

 

Drawer .................................................................. 27

 

NCR

 

2189............................................................................................................ 28

 

Component

 

Weights

 

29

 

Service

 

Clearance

 

Requirements

 

29

 

Electrical

 

Requirements

 

30

 

7403

 

Electrical

 

Requirements ................................................................................. 30

 

Peripheral

 

Power

 

Requirements ........................................................................... 30

 

Store

 

AC

 

Wiring

 

Requirements............................................................................. 30

 

Environmental

 

Requirements

 

31

 

Barometric

 

Pressure ................................................................................................ 31

 

Temperature............................................................................................................. 31

 

Humidity .................................................................................................................. 31

 

Airflow

 

Requirements

 

32

 

External

 

Cable

 

Routing

 

34

 

External

 

Peripheral

 

System

 

Cables

 

35

 

Printer

 

Cables........................................................................................................... 35

 

Powered

 

USB ..................................................................................................... 35

 

Powered

 

USB

 

(Power

 

Only) ............................................................................ 35

 

RS

232

 

(9

Pin

 

to

 

9

Pin)...................................................................................... 35

 

Display

 

Cables ......................................................................................................... 36

 

5975

 

Remote

 

Customer

 

Display

 

(Powered

 

RS

232) ..................................... 36

 

5975

 

Remote

 

Customer

 

Display

 

(RS

232

 

w/Power

 

Connector).................. 36

 

Powered

 

USB

 

(12

 

V) ......................................................................................... 36

 

VGA

 

(5942,

 

5964,

 

5965,

 

5975)........................................................................... 37

 

VGA

 

Extension

 

Cable....................................................................................... 37

 

VGA

 

Cable

 

(Integrated

 

Customer

 

Display) .................................................. 37

 

USB

 

+Power

 

(5942,

 

5964,

 

5965,

 

5975).............................................................. 38

 

Summary of Contents for RealPOS 70XRT 7403

Page 1: ...NCR RealPOS 70XRT 7403 POS Workstation Release 1 2 Site Preparation Guide B005 0000 1873 Issue C...

Page 2: ...the right to change specifications without prior notice All features functions and operations described herein may not be marketed by NCR in all parts of the world In some instances photographs are of...

Page 3: ...it contains hazardous voltages and should only be serviced by qualified service personnel The on off switch is a logic switch only The AC line voltage primaries are live at all times when the power co...

Page 4: ...in compliance with this document remains with the customer For information and guidance purposes only a list is provided in general terms of those matters for which the customer is responsible This l...

Page 5: ...Integrated 15 5942 Customer Display 10 Integrated 15 5965 Customer Display 11 Integrated 15 5966 Customer Display 12 Integrated 6 5 5982 Customer Display 13 Integrated 5975 Customer Display 14 Wall Mo...

Page 6: ...30 Environmental Requirements 31 Barometric Pressure 31 Temperature 31 Humidity 31 Airflow Requirements 32 External Cable Routing 34 External Peripheral System Cables 35 Printer Cables 35 Powered USB...

Page 7: ...RS 232 5975 38 Power 5942 12 38 Ethernet 10 100 1000BaseT 39 Dual Cash Drawer Y Cable 39 Power Cables 39 Revision Record Issue Date Remarks A Nov 2008 First issue B July 2009 Release 1 1 C Dec 2009 Re...

Page 8: ......

Page 9: ...he terminal is installed because site preparation deficiencies may be difficult to detect and correct after installation The NCR 7403 consists of separate pieces that may be combined in a variety of c...

Page 10: ...200 Intel Dual Core T1600 processor 1GB DDR2 No Hard Disk 7403 1300 Intel Core2 Duo T7500 processor 2GB DDR2 No Hard Disk 7403 F011 LCD Touch Display 15 Capacitive Used with 7403 Base only 7403 F015 L...

Page 11: ...ssociated hardware Provide and install necessary power distribution boxes conduits grounds lightning protection devices and associated hardware Ensure all applicable codes regulations and laws includi...

Page 12: ...ugh their power cords If the peripheral is powered by the terminal and has no dedicated ground then all of the ESD energy is coupled into the port connection Some devices may require the use of an in...

Page 13: ...NCR RealPOS 70XRT Site Preparation 5 Dimensions 7403 Terminal 15 w Base 26404 368 mm 14 5 in 394 mm 15 5 in 240 mm 9 4 in 375 mm 14 75 in 394 mm 15 5 in 381 mm 15 0 in 318 mm 12 25 in 193 mm 7 6 in...

Page 14: ...6 NCR RealPOS 70XRT Site Preparation 7403 Terminal 17 w Base 27697 400 mm 15 8 in 427 mm 16 8 in 240 mm 9 4 in 404 mm 15 9 in 318 mm 12 25 in 193 mm 7 6 in 396 mm 15 6 in 427 mm 16 5 in...

Page 15: ...NCR RealPOS 70XRT Site Preparation 7 7403 Terminal 15 Modular Configuration 26410 328 mm 12 9 in 368 mm 14 5 in 394 mm 15 5 in 70 mm 2 8 in 203 mm 8 0 in 282 mm 11 1 in 240 mm 9 4 in...

Page 16: ...e Preparation 7403 Terminal 17 Modular Configuration 27698 376 mm 14 8 in 77 mm 3 3 in 203 mm 8 0 in 282 mm 11 1 in 240 mm 9 4 in 400 mm 15 8 in 427 mm 16 8 in Integrated VFD Customer Display 7403 K45...

Page 17: ...NCR RealPOS 70XRT Site Preparation 9 Integrated 12 1 5942 Customer Display 26262 127 mm 5 0 in 305 mm 12 0 in 337 mm 13 25 in 114 mm 4 5 in...

Page 18: ...10 NCR RealPOS 70XRT Site Preparation Integrated 15 5942 Customer Display 26263 140 mm 5 5 in 350 mm 13 9 in 375 mm 14 75 in 107 mm 4 2 in...

Page 19: ...NCR RealPOS 70XRT Site Preparation 11 Integrated 15 5965 Customer Display 26267 140 mm 5 5 in 368 mm 14 5 in 394 mm 15 5 in 107 mm 4 2 in...

Page 20: ...12 NCR RealPOS 70XRT Site Preparation Integrated 15 5966 Customer Display 26268 152 mm 6 0 in 394 mm 15 5 in 394 mm 15 5 in 107 mm 4 2 in...

Page 21: ...NCR RealPOS 70XRT Site Preparation 13 Integrated 6 5 5982 Customer Display 27715 89 mm 3 5 in 175 mm 6 9 in 315 mm 12 4 in 165 mm 6 5 in...

Page 22: ...14 NCR RealPOS 70XRT Site Preparation Integrated 5975 Customer Display 26335 394 mm 15 5 in A 180 mm 7 1 in 224 mm 8 9 in A 5975 1xxx 5975 2xxx...

Page 23: ...ts available for the display in four inch increments 5975 K834 102 mm 4 in and 203 mm 8 in poles 5975 K836 305 mm 12 in and 406 mm 16 in poles Note The Rear Consumer Display Mount 7403 K452 is also re...

Page 24: ...16 NCR RealPOS 70XRT Site Preparation Wall Mount 7403 K320 26301 287 mm 11 3 in 244 mm 9 6 in...

Page 25: ...NCR RealPOS 70XRT Site Preparation 17 26300 178 mm 7 0 in 7 1 mm 0 28 in 102 mm 4 0 in 244 mm 9 6 in 213 mm 8 4 in Use 6 4 mm 0 25 in bolts...

Page 26: ...18 NCR RealPOS 70XRT Site Preparation Wall Mount 7403 K321 26414 73 mm 2 9 in 45 mm 1 8 in 204 mm 8 0 in 258 mm 10 2 in 102 mm 4 0 in 178 mm 7 0 in 7 1 mm 0 28 in Use 6 4 mm 0 25 in bolts...

Page 27: ...ters 7167 Thermal Receipt and Impact Slip Printer 19711g 190 mm 7 5 in 174 mm 7 0 in 262 mm 10 3 in 316 mm 12 5 in 275 mm 10 8 in 7168 Thermal Receipt and Impact Slip Printer 23537a OK 346 mm 13 6 in...

Page 28: ...20 NCR RealPOS 70XRT Site Preparation 7198 Thermal Receipt Printer 23834c 256 mm 10 1 in 145 mm 5 7 in 220 mm 8 7 in 139 mm 5 5 in...

Page 29: ...ion 21 Remote Displays 5964 15 Inch Touch LCD 21525 350 mm 13 75 in 353 mm 13 9 in 280 mm 11 0 in 5942 12 1 Inch LCD Monitor 19810b 306 mm 12 0 in 304 mm 11 9 in 190 mm 7 5 in 133 mm 5 25 in 165 mm 6...

Page 30: ...22 NCR RealPOS 70XRT Site Preparation 5942 15 Inch LCD Monitor 21524 356 mm 14 0 in 353 mm 13 9 in 228 mm 9 0 in 5965 15 Inch LCD Monitor 25820 350 mm 13 75 in 273 mm 10 75 in 394 mm 15 5 in...

Page 31: ...NCR RealPOS 70XRT Site Preparation 23 5966 15 Inch LCD Monitor 26472 220 mm 8 7 in 400 mm 15 7 in 358 mm 14 1 in...

Page 32: ...tomer Displays There are two versions of the 5975 they have the same appearance and dimensions 5975 1xxx 2x20 Remote Customer Display 5975 2xxx Graphical Remote Customer Display 22916 224 mm 8 9 in 22...

Page 33: ...ole Mount There are four different length posts available for the 5975 display in four inch increments 22917 520 mm 20 5 in 420 mm 16 5 in 320 mm 12 5 in 215 mm 8 5 in Note Heights greater than 215 mm...

Page 34: ...26 NCR RealPOS 70XRT Site Preparation Base Plate Mounting Hole Dimensions 22912 76 mm 3 0 in 76 mm 3 0 in...

Page 35: ...paration 27 Cash Drawers NCR 2181 Cash Drawer 24799 762 mm 30 0 in 442 mm 17 4 in 467 mm 18 7 in 117 mm 4 6 in w feet 127 mm 5 0 in NCR 2186 Compact Cash Drawer 23150a 700 mm 27 6 in 415 mm 16 3 in 41...

Page 36: ...28 NCR RealPOS 70XRT Site Preparation NCR 2189 20434a 133 mm 5 25 in 527 mm 20 5 in Operating and Service Clearance for Drawer 330 mm 13 0 in 464 mm 18 25 in...

Page 37: ...drawer 12 3 27 0 2189 Cash drawer 9 5 20 9 5942 12 1 Touch Monitor 2 8 6 2 5942 15 Touch Monitor 3 0 6 6 5965 Touch LCD 4 0 8 8 5966 Touch Monitor 5 4 11 9 7167 Receipt Impact Printer 4 5 10 0 7168 Re...

Page 38: ...5 Peripheral Power Requirements The number of peripherals that the terminal can support is dependent upon which peripherals are connected For planning purposes use the RealPOS 70XRT Power Matrix B005...

Page 39: ...hanges beyond the restrictions Temperature Parameter Restriction Operating 5 C to 40 C 40 F to 104 F dry bulb Storage 10 C to 50 C 14 F to 122 F three months Shipping 40 C to 60 C 40 F to 140 F one we...

Page 40: ...st not exceed 40 C 104 F Do not block the air vents on the terminal These vents are necessary for cooling 26294 Do not place the terminal in an enclosed area where sufficient ventilation is not availa...

Page 41: ...NCR RealPOS 70XRT Site Preparation 33 26954 Minimum Clearances 100 mm 4 in...

Page 42: ...Routing The cables from the I O Board are routed under the base and out the bottom of the unit Cables from the Backplane Board are routed out an opening in the Cover and down the back of the terminal...

Page 43: ...7 0441178 4 m 1416 C088 0040 Powered USB Power Only 19721 24V USB Terminal Power Printer Access Hole Diameters 23 0 mm 0 9 in 19 0 mm 0 75 in 497 0441156 1m 1432 C092 0010 497 0441157 4 m 1432 C092 00...

Page 44: ...045 0040 RS 232 Terminal 5975 Remote Customer Display RS 232 w Power Connector 22928a Access Hole Diameters 19 0 mm 0 75 in 38 0 mm 1 5 in Display D Shell 9 Pin Receptacle Modular 10 Pin Plug 497 0440...

Page 45: ...5045 4m 1416 C972 0040 VGA Extension Cable 27648 VGA Host Terminal Sub Miniature D Shell 15 Pin Plug Sub Miniature D Shell 15 Pin Receptical VGA Cable to Display 497 0461210 0 6m 1432 C372 0006 Access...

Page 46: ...ters 19 0 mm 0 75 in 23 0 mm 0 9 in Powered RS 232 5975 22927a Access Hole Diameters 19 0 mm 0 75 in 38 0 mm 1 5 in Display D Shell 9 Pin Receptacle Modular 10 Pin Plug 497 0439734 1 0 m 1432 C043 001...

Page 47: ...6 m 1416 C372 0006 Cash DWR 1 Cash DWR 2 Cash Drawer Terminal Printer Access Hole Diameters 51 0 mm 2 0 in 16 0 mm 0 63 in Power Cables 27305 The following power cables not shown also have an IEC C13...

Page 48: ...40 NCR RealPOS 70XRT Site Preparation...

Page 49: ...oblems are is not covered by the NCR Maintenance Agreement NCR accepts no liability for any such occurrence nor for its consequences When power transient suppression is required the suppressors used s...

Page 50: ...educe downtime and extend the life of the RealPOS Retail Solution For sizing and product information please call NCR Site Preparation Services at 800 257 0458 The following product offerings are avail...

Reviews: