background image

12.

 

Reassemble the unit using the reverse order. 
a.

 

Install the Top Access Cover 

b.

 

Install the Display Head onto the base 

c.

 

Connect the Display Head Cable 

d.

 

Connect the Power Cord 

e.

 

Install the Front Base Cover. 

Driver/SDK Download 

The driver and SDK can be downloaded from the Digital Persona web site. Download 
the 4500 model items. 

 

http://www.digitalpersona.com/DigitalPersona-U-are-U-Software-Development-Kits-

(SDKs)/ 

Digital Persona provides the SDK for a fee. The provider of the POS application has 
the rights to distribute the DP Run Time Engine (RTE). 

Summary of Contents for 7403-K150

Page 1: ...7403 K150 Biometrics Module Fingerprint Recognition Kit Instructions Issue B...

Page 2: ...Revision Record Issue Date Remarks A May 2009 First issue...

Page 3: ...This kit provides an integrated U are U Biometrics module for the 7403 terminal providing fingerprint recognition capabilities 27625 Biometrics Module Kit Contents 27624 Biometrics Module Screw 4 40...

Page 4: ...se for a few seconds Avoid any contact with internal parts and handle cards only by their external edges 1 Disconnect power to the terminal Caution Disconnect the AC power cord before disassembling th...

Page 5: ...3 c Pivot the top of the Front Base Cover toward the front of the unit and remove it from the terminal 26032 d Disconnect the Power Cord from the Power Supply 26135 AC Power Cord...

Page 6: ...4 2 Disconnect the Display Cable 3 Loosen the Display thumbscrews 2 26464 Display Cable Thumbscrews...

Page 7: ...5 4 Depress the Display Release Latches 2 and slide the Display Head toward the rear of the terminal to disengage it from the chassis 26151a Display Latches...

Page 8: ...scratches to the Touchscreen and Front Bezel 6 Loosen the captive screws 2 that secure the Top Access Cover and then remove the cover from the Display Head 27639 Top Access Cover 7 Remove the Top Ins...

Page 9: ...ad Fold the cable with a loop that routes through the slot in the Biometrics Module Back 27641 Cable Loop 9 Separate the Biometrics Module Back from the Biometrics Module Assembly by gently pivoting t...

Page 10: ...is a square slot in the Rear Cabinet that the cable is routed through Note Make sure the Plastic Insulator is installed 27640 Biometrics Module Back Biometrics Module Front Plastic Insulator b Secure...

Page 11: ...Cord e Install the Front Base Cover Driver SDK Download The driver and SDK can be downloaded from the Digital Persona web site Download the 4500 model items http www digitalpersona com DigitalPersona...

Page 12: ...r Cleaning Procedure section Normal Usage Place your finger flat and straight on the sensor If this is not possible try to place your finger on the sensor in the same angle every time Registering a Ne...

Page 13: ...s it down too firmly or too lightly Exert approximately the same amount of pressure as if you were pressing a doorbell button Choose the correct finger To obtain a good fingerprint image and a good fi...

Page 14: ...finger on the reader until you see the reader light blink This can take longer if the skin is dry Then lift your finger Although you may use any finger with the reader your index finger of either hand...

Page 15: ...stem 2 Click the Hardware tab 3 Click the Device Manager button In the Device Manager verify that you have an entry called Universal Serial Bus controller If this entry does not exist you need to cont...