NCP S115A-10K10 Installation Instructions Manual Download Page 13

Warranty

11

NCP warrants the accompanying split air conditioner or heat pump system to be free of defects 
in material and workmanship for the applications specified in the operation manual and installa-
tion manual for a period of one (1) year on parts and five (5) years on compressor, valid from the 
date of original retail purchase in the United States or Canada. Labor is not covered under 
warranty.

If the unit exhibits a defect in normal use and is determined to be within the warranty period, 
NCP will, at its option, either repair or replace the unit free of charge within a reasonable time 
after the unit is returned.

This warranty DOES NOT cover:
• 

Damage, accidental or otherwise, to the unit while in possession of the consumer that is 
not a result of a defect in material in workmanship.

• 

Damage caused by consumer misuse, tampering, or failure to follow all care and mainte-
nance instructions in the manuals.

• 

Damage to the finish of the case or other parts caused by water.

• 

Damage caused by repairs or alterations to the unit by anyone other than a qualified 
technician.

• Filter.
• 

Freight and insurance cost for the warranty service.

 

Damage caused by mis-wiring the unit(s).

Warranty Activation Card must be completed and sent in to activate the warranty for the accom-
panying unit.

Summary of Contents for S115A-10K10

Page 1: ...allation Instructions Mini Split Air Conditioning or Heat Pump Systems Air Conditioning S115A 10K10 S115A 13K10 S240A 13K11 Heat Pump S115HP 10K10 S115HP 13K10 S240HP 13K11 950 0004 Rev 7 28 October 2...

Page 2: ...Contents Specifications 1 Unit Parts Features 2 Installation Dimension Diagram 3 Safety Warnings 4 Select Installation Locations 5 Indoor Unit Installation 7 Outdoor Unit Installation 8 Testing 10 War...

Page 3: ...40A 13K11 Indoor replacement S240A 13K11 I Outdoor replacement S240A 13K11 O 12 500 BTU 11 Seer Heat Pump S115HP 10K10 9 500 BTU 10 5 Seer Indoor replacement S115HP 10K10 I Outdoor replacement S115HP...

Page 4: ...HR Air in Panel Air filter Indoor Unit Outdoor Unit Air out Louver Wiring cover Cover plate of electric box Remote control Drain hose Connecting pipe Cooling indicator Heating indicator On Off indicat...

Page 5: ...in deep 21 3 in high Distance to ceiling should be 6 inches or more Distance to wall should be 6 inches or more Distance to floor should be 80 inches or more Distance to wall should be 6 inches or mor...

Page 6: ...Electrical installation must be done by a qualified technician according to instruction manual and in accordance with local electrical standards Certified power supply conductors must be used INSTALL...

Page 7: ...uch as televi sions radios etc Keep unit and remote out of direct sunlight and or flourscent lighting and away from any excessive heat source steam or flammable materials Outdoor Unit Allow sufficient...

Page 8: ...se extension is included with unit for use if attached drainage line is not long enough for your application Please note that the extension can be installed after existing drainage pipe is fed through...

Page 9: ...Wire Table para 4 for wire sizes 5 L N G 4 5 6 way terminal board Outdoor Unit 2 3 2 3 L N G N 1 N 1 3 way terminal board Indoor Unit Power Supply Connections 115 VAC Air Conditioner Wiring See Wire T...

Page 10: ...tion pipes to the proper pipes of the bundled lines coming through the wall from the indoor unit Tighten the flare nut of the connection pipes using a spanner and torque wrench see diagram Note Do not...

Page 11: ...tdoor Unit Remove valve caps on outdoor unit Use standard A C practices to attach the refrigeration lines bundled in Step 2 to the outdoor unit Tighten the flare nut of the connection pipes using a sp...

Page 12: ...n gas and liquid valves completely 4 System Testing Before testing the system ensure that cut off valves of the connection pipes are opened and that all debris such as packing scraps thrums etc are cl...

Page 13: ...place the unit free of charge within a reasonable time after the unit is returned This warranty DOES NOT cover Damage accidental or otherwise to the unit while in possession of the consumer that is no...

Page 14: ...Indoor Unit Catalog Number S115A 10K10 O S115A 10K10 I N A 1070 1000 930 0 065HP 0 9A 0 008HP 0 18A 55 32 35 38 Hitachi SG453EA1NC N A 40A N A 8 8A N A 313 Psig 313 Psig 144 Psig 144 Psig N A MP24GA 3...

Page 15: ...Number S240A 13K11 O S240A 13K11 I N A 1100 1200 1350 0 064HP 0 56 Amps 0 03HP 0 16 Amps 57 39 41 44 PANISONIC 2P19S236A1J N A 33 A N A 5 7 A N A 384 Psig 384 Psig 144Psig 144 Psig N A MP24GA 33 x 12...

Page 16: ...og Number S115A 13K10 O S115A 13K10 I 1100 1200 1350 0 064 HP 0 9 Amps 0 29 HP 0 2 Amps 57 39 41 44 Panasonic 2P19S126B1F N A 62 A N A 10 6 A N A 313 Psig 313 Psig 144 Psig 144 Psig N A MP24GA 33 x 12...

Reviews: