background image

 

                

 

MADE IN USA

 

                                                             NCM Supplies Inc. 

2101 N.W. 79 Ave. Miami, Florida 33122 

Phone: 305-640-0461 Fax: 305-639-2684 

[email protected] 

www.ncmsupplies.com

 

2

Front Panel:

The front panel is shown in Figure.

1-

Power LED

- Lights up when the key is turned on.

2- 

 RF LED ALARM

-Lights up green when the output RF power is ok or red when out of range.

3-  

PD LED ALARM

- Lights up green when the input optical power is ok or red when out of range.

4- 

Power On Key

- Turns on/off the power

5-

LCD

- Information Display

6-

U, D, R and F key

- Four key  from key-board

Rear Panel:

The Rear Panel is shown in Figure.

1-

RF Output

- 75Ω F-type connector input RF signal

2-

RS-232

- DB9 Serial Monitoring Interface (Bit rate: 9600bps, Data bits: 8, Parity: None, Stop bits: 1)

3-

Optical Input

-Class 3B, SC/APC or FC/APC connector

4-

Power Jack

- Supplies power to the equipment

5-

Fuse

- A 220V 1.5A fuse to protect the equipment against short circuits and power surges

6-

RF Test Point

-75Ω F-type connector -20dB input RF signal test point

7-  GND

-Case ground

1

2

4

3

5

6

OPTICS

POWER

OPTICAL RECEIVER

OFF

ON

POWER ON

KEY

RF

PD

MODEL OR-200

D

F

U

R

RX#1 RX#2 RX#3 RX#4  
^ OK  OFF   OK  ALM

MONITORING

INTERFACE

RS-232

OPTCAL IN

110-220 Vac/ 50-60 Hz

RF INPUT

RX-1

OPTCAL IN

OPTCAL IN

OPTCAL IN

RF-TP

RF-TP

RF-TP

RF-TP

RX-2

RX-3

RX-4

RF-OUT

RF-OUT

RF-OUT

RF-OUT

-20dB

-20dB

-20dB

-20dB

7

5

4

3

2

1

6

8125 NW 64th Street, Miami, Florida 33166

 

 

 4 Channels Optical Receiver

NCM-OR-200

Summary of Contents for NCM-OR-200

Page 1: ...tested by NCM OPTICS NCM OR 200 includes 1 NCM OR 200 1 2 AC Power Cord 1 3 Keys 2 4 Datasheet 1 6 Installation Guide 1 MADE IN USA NCM Supplies Inc 2101 N W 79 Ave Miami Florida 33122 Phone 305 640 0...

Page 2: ...ector input RF signal 2 RS 232 DB9 Serial Monitoring Interface Bit rate 9600bps Data bits 8 Parity None Stop bits 1 3 Optical Input Class 3B SC APC or FC APC connector 4 Power Jack Supplies power to t...

Page 3: ...h purity isopropyl alcohol Dry the surfaces using dry compressed air Installation Instructions 1 Use 4 screws to attach the receiver OR 200 to 19 rack mounting 2 Connect the RF coax into RF output F t...

Page 4: ...enable but alarmed ALM While OR 200 stays on main display it is monitoring the principal parameters of the receiver and sends serial data via RS 232 to monitor on personal computer RX 1 RX 2 RX 3 RX 4...

Page 5: ...in display By staying in this display OR 200 can monitor the modules Use U or D to measure the RF and Optical signal per module The second picture below displays when the signals are not detected RX 1...

Page 6: ...While the monitor is navigating the serial RS 232 is stopped Fan Current 67 00 mA Temperature Inside o 26 00 C 18 V Power Supply 18 0 V 5 V Power Supply 5 0 V 5 V Power Supply 5 0 V 14 The next displ...

Page 7: ...of 500mS 16 Critical Condition When the alarm conditions occurs and the system detects malfunction that may cause damage to the PHOTODIODES turn it off to protect the life of the PHOTODIODES Warning...

Reviews: