NCE Power Pro System Reference Manual Download Page 6

6

Press to set up the address.

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

SETUP ADR  1=YES

SETUP ADR  1=YES

SETUP ADR  1=YES

SETUP ADR  1=YES

SETUP ADR  1=YES

By convention all DCC locomotive decoders are set to short address #3 at the factory. If
your decoder has not had its address changed you will see a short address as the active
address.

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

ACTIVE ADR:SHORT

SHORT ADR:   003

SHORT ADR:   003

SHORT ADR:   003

SHORT ADR:   003

SHORT ADR:   003

TIP A decoder can have 2 different addresses, the Short Address (values from 1-127) or
the Long Address (sometimes called 4 digit with a range of 0000-9999). A decoder can
use one or the other but not both at the same time. Some entry level decoders can only
use the Short Address.

#8 Press ENTER to keep the current short address set to 3.

#9 Press ENTER again to skip activating the short address.

#10 Next you will see the Long Address (which is probably set to 0000 or sometimes to

9999). With older decoders, it may take a up to 30 seconds to read the long address.

This is the address we will change.

#11 You will likely want to enter the number on the side of the locomotive cab as the

Long Address. Type in the number of the locomotive and press ENTER.

#12 Press 1 to activate the Long Address.

You have just changed the Long Address.

At this point, press PROG/ESC twice to exit the program track mode.

You have just completed the hardest part of DCC… programming the locomotive on the
programming track.

By now the left status light of the booster will be glowing steadily indicating that track
power has been restored. Put your freshly programmed locomotive back on the test
track, it won’t run on the programming track.

To select the locomotive:

a. Press SELECT LOCO button
b. Press the digits corresponding to the Long Address you just programmed..

c. Press ENTER

At this point you should have control of the locomotive. Now is the time to program up a
second locomotive and run them both.

RUNNING TWO LOCOMOTIVES WITH ONE CAB

#1 Select the first locomotive you wish to run (SELECT LOCO followed by address then

ENTER).

#2 Press RECALL to store this locomotive in one of the internal recall “slots” of the cab.

The display of the cab will now show a locomotive of 000.

#3 Select the second locomotive and start running it.

#4 By pressing RECALL you can toggle back and forth between the two different

locomotives. At any time you can select a new locomotive “over the top” of any
locomotive already on the display. The existing locomotive will be forgotten by the cab
with the new one taking it’s place. The one in RECALL will remain available for recall.

Summary of Contents for Power Pro

Page 1: ...1 Version 3 1 07 System Reference Manual System Reference Manual Power Pro Power Pro...

Page 2: ...system If you are using a different transformer be sure to measure the actual no load voltage before connecting it to your system Many 16 Volt transformers put out 19 to 20 Volts with no load If you h...

Page 3: ...ll be a similar indication if the DCC signal from the command station is lost The Power Pro is factory adjusted to put out the NMRA recommended 14 25 volts for N HO and S scales 5 Set up a test track...

Page 4: ...t where the numbers will go you can press the PROG ESC key to escape what you were doing and return to normal operation mode TIP 3 Whenever you have pressed a button such as SELECT LOCO and you want t...

Page 5: ...TRK xx xx represents the fast clock which may display any time at this point 4 Press ENTER to use the programming track and you will see PROG TRK xx xxPM PROG TRK xx xxPM PROG TRK xx xxPM PROG TRK xx...

Page 6: ...ype in the number of the locomotive and press ENTER 12 Press 1 to activate the Long Address You have just changed the Long Address At this point press PROG ESC twice to exit the program track mode You...

Page 7: ...de red and the other side blue You could also place a tag with a sign on one side and a tag with a sign on the other This way when dropping leads down to your track bus polarity is assured by using th...

Page 8: ...8 Advanced Layout Wiring NCE PROCAB NCE PROCAB POWER PRO EB3 PH Pro P515 RB02 UTP UTP UTP ProCab R Cab04E Cab04P ProCab DPDT Switch Program Mainline Track NCE Mine Processor...

Page 9: ...ss Long or Short Enter Address Run Loco 2 CV Enter CV Enter Value 3 CFG CV29 Direction Bit Speed Steps DC Mode Adv Acknowledge SpeedTable Address 4 Motor Control Start Volts Max Volts Mid Volts Accel...

Page 10: ...ntum Decel Rate Estop Shutdown Enable Radio Fix AIU Broadcast Enable 1 Standard Manufacturer Decoder Version Set Up Address Set Config Motor Control Function Map Set CV 2 CV Enter CV Enter Value 6 SET...

Page 11: ...11 NCE Corporation 82 East Main Street Webster NY 14580 585 265 0230 ncedcc com 05240300 05240300 05240300 05240300 05240300 05240300...

Reviews: