bus is less than 2 feet. Use of a smaller bus will prevent the 
booster from detecting a short circuit and may be a fire 
hazard.

The voltage to the track is dependent on the power source 
input voltage as discussed below. The DCC track voltage 
can be changed from 13.8 to 12 Volts by setting the switch 
on the power supply for N, HO and some S Scales. We offer 
a 9 Volt power source for Z Scale. Please call us at 585-265-
0230 for a replacement. We do not recommend using a 5 
Amp booster with O-Scale as most O-Scale locomotives 
have stall currents in the area of 8 Amps (Weaver, Red 
Caboose, P&D). For O-Scale usage we recommend our 
PB110 ten Amp power booster.

CONTROL BUS SOCKETS
The control bus sockets on the front of the PB5 are paired to 
allow wiring the control signal coming from the command 

station to “daisy chain” through the booster. 

Use the supplied 7 foot cable to connect the PB5 to your 
command station’s CONTROL BUS socket. The remaining 
(unused) socket on the PB5 can be used to connect to other 
Boosters in daisy chain fashion. Use only the 4-wire RJ-H 
cable for this purpose. Longer cables may be used if more 
distance is needed between power stations. The last power 
station at the end of the daisy chain will have one empty 
socket. The PB5 will place a nominal 6mA load on the 
command station control bus. 

STATUS LIGHT

Page 3

TRACK

STATUS POWER

18VDC MAX.

PB5

FIVE AMP POWER BOOSTER

CONTROL BUS

POWER PRO

From Command Station

7 foot Cable

To other Power Boosters

This light will illuminate light steadily under normal 
operations. Flashing indicates an abnormal or fault condition. 
Here is a description of the various conditions indicated by 
the status light.

Steady on - Track power is on and operations are 

normal.

Rapid flash - No DCC signal from command station 

(control bus cable is unplugged, programming track in 
use, etc.)

Slow flash - Short circuit in the layout wiring, the layout 

track or in a locomotive.

POWER SOCKET:
Input power from the outside power supply goes into the 
PB5 via the round socket. Use ONLY the NCE supplied 
P514 power supply.

TRACK VOLTAGE ADJUSTMENT
The track voltage can be changed between 12 Volts and 
13.8 Volts by setting the switch on the P514 power supply.

CONNECTING THE PB5 TO OTHER SYSTEMS

WIRING TO A LENZ COMMAND STATION
This wiring diagram is provided for the operators that wish to 
add an NCE power booster to their existing LENZ system. 
Lenz does not provide a ground point. 

Page 4

Red

Green

Cut off black wire

Cut off yellow wire

6 position RJ-12

connector

Supplied 4 position

RJ-H cable

Connection from Digitrax command station to NCE boosters

Blue

White

Yel

Grn

Red

Blk

NOTE: Connect one of the NCE booster cover screws to the ground connection of other boosters in the system

Connect to NCE booster

"Control Bus" jack

Connect to Digitrax

LocoNet jack

Splice wires

Reviews: