NCE EB1 User Manual Download Page 5

CV132/133

 -

 

Accessory address

CV132

 default = 143 high byte of accessory address 

CV133

 default = 191 Low byte of accessory address 

Don't try to set these CVs by manually programming 

CVs.

Use the "setup" jumper method above to set the accessory address.

If manual reset is enabled

, track power through the 

EB1

 can be turned on/off (or turned back

on after a short circuit shutdown) by controlling the 

EB1

 as a

ccessory (turnout).  ON/Normal

turn track power on and OFF/reverse turns it off/

CV135-CV146

 -

 

Custom Startup Table

 (Note: this if for the technically inclined)

The custom startup table provides a programmable method to pulse the track power on and

off several times before the 

EB1

 tests for 

overcurrent.

 You can program the on and off times

in increments of 

1mS.

  Generally you will not use this table with most boosters but it may be

useful with a booster that has weak startup capability. 

An "off" time of 0 indicates the last entry of table. With the factory default of 

CV144

 = 0

indicates the 

EB1

 will not try to use the 6th "on" time.

If 

CV135

 = 0 the table is disabled. 

CV135

 default = 0 Custom startup table initial "on" time 

CV136

 default = 4 Custom startup table initial "off" time

CV137

 default = 8 Custom startup table 2nd "on" time

CV138

 default = 4 Custom startup table 2nd "off" time

CV139

 default = 16 Custom startup table 3rd "on" time

CV140

 default = 4 Custom startup table 3rd "off" time

CV141

 default = 32 Custom startup table 4th "on" time

CV142

 default = 4 Custom startup table 4th "off" time

CV143

 default = 80 Custom startup table 5th "on" time

CV144

 default = 0 Custom startup table 5th "off" time

CV145

 default = 0 Custom startup table 6th "on" time

CV146

 default = 0 Custom startup table 6th "off" time

CV147

 Factory reset 

Set 

CV147

 = 85 to do a factory reset of the 

EB1

 to the following values. 

CV129

 default = 1       

16mS

 allowable short circuit

CV130

 default = 128   2 seconds power off time

CV131

 default = 0       Manual reset off

CV132 

default

 = 143   High byte of accessory 

address 

2044

CV133 

default

 = 191   Low byte of accessory address 2044

CV13

5 default = 0       Custom startup table disabled

CV136

 default = 4 

CV137

 default = 8 

CV138

 default = 4 

CV139

 default = 16 

CV140

 default = 4 

CV141

 default = 32 

CV142

 default = 4 

CV143

 default = 80 

CV144

 default = 0 

CV145

 default = 0 

CV146

 default = 0 

**Last revised:  

5 February 2008

Page 5

EB

1

Reviews: