NCE AR10 Quick Start Manual Download Page 5

Setting up CV’s and their values: Optional - Not Required

Method 1:

Any DCC system that has OPs mode programming (Program On the Main) for

 

locomotives

can program CVs.  Whenever the “SETUP” button is pressed the AR10 will flash the SHORT
LED at 1 second intervals indicating it is ready to respond to loco OPS mode programming no
matter what locomotive address is used.  We recommend choosing an address that is not in
use on your layout (we use 9999).    The SHORT LED must be flashing to use this method of
setting CVs. The LED will flash rapidly until an OPs programming command is received by the
AR10 or until 60 seconds has elapsed at which point the AR10 will return to normal
operations.   

Using method 1 you must press SETUP before each CV you wish to program. 

Method 2 (NCE Specific):

If you have an NCE (or other system) that supports OPs mode programming of 

accessories

you can program CVs without having to press the “SETUP” button for every CV.  

The AR10 comes from the factory preprogrammed to the accessory address of 1.  

To change the address:

Press the “SETUP” button (the LED will start flashing)

Press SELECT ACCY on your controller

Type in the new address you want to AR10 to use followed by ENTER

Press 1 (for NORMAL) when prompted on your controller

The LED will stop flashing and the AR10 will return to normal operations 

The AR10 will now respond to Accessory Programming at the address you just programmed.

Using method 2 you 

will not

 need to press the SETUP again to program CVs when using

PROGRAM ACCESSORIES ON THE MAIN mode with an NCE system.

Fine Tuning the AR10

CV129 - Adjustment of short circuit response time (if necessary):

You can adjust the time delay between the occurrence of a short circuit and the time the track
actually gets shut down.  The AR10 comes factory set to 16mS (16 milliseconds = 16
thousandths of a second).  This setting has been chosen because it can be used without
problem on most layouts.   You can lengthen this delay from 16ms (1/60th second) out to
512mS (1/2 second).    Program CV129 to the number of milliseconds (divided by 16) you
desire between 16mS and 500mS. A value of 1 = 16mS, a value of 32 = 512mS, etc.

CV130 - Adjustment of short circuit shutdown time (if necessary):

You can adjust the time the track power stays off after a short circuit is detected.  The AR10
comes factory set to 2 seconds.  This setting has been chosen because it can be used
without problem on most layouts.   You can change this delay anywhere from 16mS to 4
seconds.    Program CV130 to the number of milliseconds (divided by 16) you desire. A value
of 1 = 16mS, a value of 125= 2 seconds, 250 = 4 seconds, etc.

CV131 -

 

Manual reset enable.

If CV131 is set to 0 the manual reset is disabled and the AR10 will automatically try to turn on
track power after a short circuit.  If CV131 is set to 1 the AR10 will not automatically restore
track power after a short circuit until a connection (usually with a pushbutton) is made
between he RST terminals of the four position terminal strip.  You can also turn the track
power back on by selecting the accessory address and setting the accessory to ON (also
known as Normal, Thrown or +) . 

**Last revised:  3 May 2020

Page 5

AR10

Summary of Contents for AR10

Page 1: ...screw terminals no soldering Solid state design provides silent reliable operation Status indication LED Additional output for remote LED Automatic or manual reset after short circuit shutdown Adjust...

Page 2: ...g a short dead section the length of the longest metal truck in the train This will be required at both the entrance and exit of the loop The terminal strips on the AR10 accept up to 12 AWG wire We re...

Page 3: ...desired position The diagram below shows the settings Testing the installation After setting the trip current we recommend testing your wiring The quarter test is the fastest way to test your wiring U...

Page 4: ...at set the current trip level See page 3 for a description Connections to the AR10 MAIN TRACK DCC power input from the DCC booster LOOP DCC track power output terminal from the AR10 to the loop track...

Page 5: ...program CVs when using PROGRAM ACCESSORIES ON THE MAIN mode with an NCE system Fine Tuning the AR10 CV129 Adjustment of short circuit response time if necessary You can adjust the time delay between...