7 Maintenance
You can find a troubleshooting guide for common system problems in the Linescanner manual.
System specific problems you can find listed below.
7.1 Troubleshooting
Table 7-1: Troubleshooting
Checkpoint
Possible Cause / Solution
Kiln Trigger
The system has lost synchronization due to missing signals from the position indicator:
•
Check alignment and distance between trigger bar and position indicator.
•
Increase the metal mass of the trigger bar for a reliable signal generation.
•
Check the wiring.
Note: The trigger signal can be verified by a blinking LED on the junction box located close to the position
indicator!
Ethernet Communication
via Fiber Optic
If there is no communication after installation and powering of all components required - please check the
‘cross-over’ of the two fibers between the glass fiber converter in the field and the control room (TX is in all
cases to be connected to RX of the other converter)!
TSM
Use only position indicators supplied from the manufacturer!
Note
To get quick help send a detailed error report to the TechSupport Team of the manufacturer
including the current configuration files!